1、August 2016 English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.080.40!%Y.L“2541141www.din.deD
2、IN EN 1504-8Products and systems for the protection and repair of concrete structures Definitions, requirements, quality control and AVCP Part 8: Quality control and Assessment and verification of the constancy of performance (AVCP);English version EN 1504-8:2016,English translation of DIN EN 1504-8
3、:2016-08Produkte und Systeme fr den Schutz und die Instandsetzung von Betontragwerken Definitionen, Anforderungen, Qualittskontrolle und AVCP Teil 8: Qualittskontrolle und Bewertung und berprfung der Leistungsbestndigkeit (AVCP);Englische Fassung EN 1504-8:2016,Englische bersetzung von DIN EN 1504-8
4、:2016-08Produits et systmes pour la protection et la rparation de structures en bton Dfinitions, prescriptions, matrise de la qualit et EVCP Partie 8: Matrise de la qualit et valuation et vrification de la constance des performances (EVCP);Version anglaise EN 1504-8:2016,Traduction anglaise de DIN E
5、N 1504-8:2016-08SupersedesDIN EN 1504-8:2005-02See start of applicationwww.beuth.deDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.Document comprises 17 pages 07.16 2 A comma is used as the decimal marker. Start of application The s
6、tart of application of this standard is 2016-08-01. For DIN 1504-8:2005-02 there is a transition period ending on 2018-02-28. National foreword This document (EN 1504-8:2016) has been prepared by Technical Committee CEN/TC 104 “Concrete and related products” (Secretariat: DIN, Germany). The responsi
7、ble German body involved in its preparation was DIN-Normenausschuss Bauwesen (DIN Standards Committee Building and Civil Engineering), Working Committee NA 005-07-06 AA Schutz, Instandsetzung und Verstrkung (SpA zu CEN/TC 104/SC 8). Amendments This standard differs from DIN EN 1504-8:2005-02 as foll
8、ows: a) the terminology has been brought in line with the Construction Products Regulation (Regulation (EU) No 305/2011). Previous editions DIN EN 1504-8: 2005-02 DIN EN 1504-8:2016-08 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1504-8 May 2016 ICS 91.080.40 Supersedes EN 1504-8:2004English
9、 Version Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality control and AVCP - Part 8: Quality control and Assessment and verification of the constancy of performance (AVCP) Produits et systmes pour la protection et la rparationde structure
10、s en bton - Dfinitions, prescriptions, matrise de la qualit et EVCP - Partie 8 : Matrise de la qualit et valuation et vrification de la constance des performances (EVCP) Produkte und Systeme fr den Schutz und die Instandsetzung von Betontragwerken - Definitionen, Anforderungen, Qualittskontrolle und
11、 AVCP - Teil 8: Qualittskontrolle und Bewertung und berprfung der Leistungsbestndigkeit (AVCP) This European Standard was approved by CEN on 12 March 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the s
12、tatus of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French,
13、 German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cr
14、oatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
15、 United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No
16、. EN 1504-8:2016 EEN 1504-8:2016 (E) 2 Contents Page European foreword . 3 1 Scope 4 2 Normative references 4 3 Terms and definitions . 4 4 Sampling . 5 4.1 General 5 4.2 Record . 5 4.3 Frequency of sampling 5 5 Assessment and verification of the constancy of performance (AVCP) . 6 5.1 General 6 5.2
17、 Type testing . 6 5.2.1 General 6 5.2.2 Test samples, testing and compliance criteria . 7 5.2.3 Test reports . 7 5.2.4 Shared other party results . 7 5.2.5 Cascading determination of the product-type result . 8 5.3 Factory Production Control (FPC) . 9 5.3.1 General 9 5.3.2 Requirements . 9 5.3.3 Pro
18、duct specific requirements 11 5.3.4 Initial inspection of factory and of FPC 12 5.3.5 Continuous surveillance of FPC only for products covered by AVCP system 1+, 1 and 2+ 12 5.3.6 Procedure for modification 13 5.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in
19、 very low quantity . 13 6 Marking and labelling . 14 Bibliography . 15 DINEN1504-8:2016-08EN 1504-8:2016 (E) 3 European foreword This document (EN 1504-8:2016) has been prepared by Technical Committee CEN/TC 104 “Concrete and related products”, the secretariat of which is held by DIN. This European
20、Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by November 2016, and conflicting national standards shall be withdrawn at the latest by February 2018. Attention is drawn to the possibility that some of the elemen
21、ts of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1504-8:2004. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Assoc
22、iation. The main changes that have been made in this new edition are as follows: The wording has been adapted to the CPR (Regulation (EU) No. 305/2011). EN 1504 consists of the following parts under the general title Products and systems for the protection and repair of concrete structures Definitio
23、ns, requirements, quality control and AVCP. Part 1: Definitions Part 2: Surface protection systems for concrete Part 3: Repair concrete and mortars Part 4: Structural bonding Part 5: Concrete injection Part 6: Anchoring of reinforcing steel bar Part 7: Reinforcement corrosion protection Part 9: Gene
24、ral principles for the use of products and systems Part 10: Site application of products and systems and quality control of the works According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Aust
25、ria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Swede
26、n, Switzerland, Turkey and the United Kingdom. DIN EN 1504-8:2016-08 EN 1504-8:2016 (E) 4 1 Scope This Part of EN 1504 specifies procedures for sampling, quality control, assessment and verification of the constancy of performance (AVCP) including marking and labelling of products and systems for th
27、e protection and repair of concrete according to EN 1504-2 to EN 1504-7. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated refer
28、ences, the latest edition of the referenced document (including any amendments) applies. EN 1504-1, Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality control and evaluation of conformity - Part 1: Definitions EN 1504-2, Products and system
29、s for the protection and repair of concrete structures - Definitions, requirements, quality control and evaluation of conformity - Part 2: Surface protection systems for concrete EN 1504-3, Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality
30、 control and evaluation of conformity - Part 3: Structural and non-structural repair EN 1504-4, Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality control and evaluation of conformity - Part 4: Structural bonding EN 1504-5, Products and sys
31、tems for the protection and repair of concrete structures - Definitions, requirements, quality control and evaluation of conformity - Part 5: Concrete injection EN 1504-6, Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality control and evalu
32、ation of conformity - Part 6: Anchoring of reinforcing steel bar EN 1504-7, Products and systems for the protection and repair of concrete structures - Definitions, requirements, quality control and evaluation of conformity - Part 7: Reinforcement corrosion protection 3 Terms and definitions For the
33、 purposes of this document, the terms and definitions given in EN 1504-1 and the following apply. 3.1 batch quantity of material made in a single operation, or in the case of continuous production for a defined quantity (in tonnes) which shall be demonstrated by the producer to have a uniform compos
34、ition and shall not exceed one days production 3.2 identification test test carried out to verify a declared value of the composition or property of the product or system in terms of consistency of the production Note 1 to entry: This is to ensure that the product or system being tested corresponds
35、to the product or system subjected to the initial type test, within the permitted tolerances. DIN EN 1504-8:2016-08 EN 1504-8:2016 (E) 5 3.3 performance test test carried out to verify a value for essential characteristics of the product or system in terms of its specified performance during applica
36、tion and use Note 1 to entry: This is to ensure that the product or system conforms to its specified performance characteristics. 3.4 declared value value declared and documented by the manufacturer for identification or essential characteristics 4 Sampling 4.1 General Sampling shall be carried out
37、in such a way that the resulting sample is homogeneous and representative of the batch or product to be inspected. Samples shall be clearly labelled to uniquely identify the source, location and time of sampling. The sample size shall be sufficient for all the required testing in accordance with the
38、 relevant test method standards. A part of the sample should be retained for future reference until the use by date. 4.2 Record All information relevant to the sampling shall be recorded, including in particular: a) date of manufacture and sampling; b) unique identification of the product and of the
39、 sample(s); c) type of material and quantity of sample(s); d) name of the manufacturer; e) manufacturers batch identification number; f) quantity of batch or product represented by the sample; g) physical state; h) colour or appearance; i) name(s) of the person(s) responsible for sampling; j) method
40、 of sampling. 4.3 Frequency of sampling For frequency of sampling see frequency of testing in EN 15042 to EN 15047. DIN EN 1504-8:2016-08 EN 1504-8:2016 (E) 6 5 Assessment and verification of the constancy of performance (AVCP) 5.1 General The compliance of the products and systems for the protectio
41、n and repair of concrete structures with the requirement of this standard and with the performances declared by the manufacturer in the DoP shall be demonstrated by: determination of the product-type; factory production control by the manufacturer, including product assessment. The manufacturer shal
42、l always retain the overall control and shall have the necessary means to take responsibility for the conformity of the product with its declared performance(s). NOTE The assignment of tasks to the notified bodies and the manufacturer is shown in the Annexes ZA (Table ZA.3 and following Tables) of t
43、he relevant part of the EN 1504 series. 5.2 Type testing 5.2.1 General All performances related to characteristics included in this standard shall be determined when the manufacturer intends to declare the respective performances unless the standard gives provisions for declaring them without perfor
44、ming tests. (e.g. use of previously existing data, CWFT and conventionally accepted performance). Assessment previously performed in accordance with the provisions of this standard, may be taken into account provided that they were made to the same or a more rigorous test method, under the same AVCP
45、 system on the same product or products of similar design, construction and functionality, such that the results are applicable to the product in question. NOTE 1 Same AVCP system means testing by an independent third party only for products covered by system 1+, 1 and 3, under the responsibility of
46、 a notified product certification body only for products covered by system 1+ and 1. For the purposes of assessment, the manufacturers products may be grouped into families, where it is considered that the results for one or more characteristics from any one product within the family are representat
47、ive for that same characteristics for all products within that same family NOTE 2 Products may be grouped in different families for different characteristics. Reference to the assessment method standards should be made to allow the selection of a suitable representative sample. In addition, the dete
48、rmination of the product-type shall be performed for all characteristics included in the standard for which the manufacturer declares the performance: at the beginning of the production of a new or modified product or system for the protection and repair of concrete structures (unless a member of th
49、e same product range), or at the beginning of a new or modified method of production (where this may affect the stated properties); or they shall be repeated for the appropriate characteristic(s), whenever a change occurs in the product or system for the protection and repair of concrete structures design, in the raw material or in the supplier of the components, or in the method of production (subject to the definition of a