DIN EN 179-2008 Building hardware - Emergency exit devices operated by a lever handle or push pad for use on escape routes - Requirements and test methods English version of DIN EN.pdf

上传人:progressking105 文档编号:668715 上传时间:2018-12-25 格式:PDF 页数:63 大小:1.03MB
下载 相关 举报
DIN EN 179-2008 Building hardware - Emergency exit devices operated by a lever handle or push pad for use on escape routes - Requirements and test methods English version of DIN EN.pdf_第1页
第1页 / 共63页
DIN EN 179-2008 Building hardware - Emergency exit devices operated by a lever handle or push pad for use on escape routes - Requirements and test methods English version of DIN EN.pdf_第2页
第2页 / 共63页
DIN EN 179-2008 Building hardware - Emergency exit devices operated by a lever handle or push pad for use on escape routes - Requirements and test methods English version of DIN EN.pdf_第3页
第3页 / 共63页
DIN EN 179-2008 Building hardware - Emergency exit devices operated by a lever handle or push pad for use on escape routes - Requirements and test methods English version of DIN EN.pdf_第4页
第4页 / 共63页
DIN EN 179-2008 Building hardware - Emergency exit devices operated by a lever handle or push pad for use on escape routes - Requirements and test methods English version of DIN EN.pdf_第5页
第5页 / 共63页
点击查看更多>>
资源描述

1、April 2008DEUTSCHE NORM English price group 22No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.190!$NBO“1433144www.d

2、in.deDDIN EN 179Building hardware Emergency exit devices operated by a lever handle or push pad, for useon escape routes Requirements and test methodsEnglish version of DIN EN 179:2008-04Schlsser und Baubeschlge Notausgangsverschlsse mit Drcker oder Stoplatte fr Tren in Rettungswegen Anforderungen u

3、nd PrfverfahrenEnglische Fassung DIN EN 179:2008-04SupersedesDIN EN 179:2002-06www.beuth.deDocument comprises 63 pagesDIN EN 179:2008-04 2 National foreword This standard has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling” (Secretariat

4、: AFNOR, France), Working Group WG 4 “Building hardware” (Secretariat: BSI, United Kingdom). The responsible German body involved in its preparation was the Normenausschuss Bauwesen (Building and Civil Engineering Standards Committee), Technical Committee NA 005-09-50 AA Paniktr- und Notausgangs-ver

5、schlsse. Explanatory note Paragraph 3 of 1 Scope reads as follows: This European Standard covers emergency exit devices, which are either manufactured and placed on the market in their entirety by one producer, or produced by more than one producer and subsequently placed on the market as a kit in a

6、 single transaction. The expression “placed on the market as a kit in a single transaction” refers for instance to the fact that a manufacturer of an emergency exit device can instruct building hardware dealers or door manufacturers in such a manner that the latter can select an exit device and a su

7、itable (permissible) fitting themselves, using as a basis documentation provided by the emergency exit device manufacturer. Amendments This standard differs from DIN EN 179:2002-06 as follows: a) Parts of the scope have been included in the introduction. b) Clause 3 “Terms and definitions” has been

8、extended. c) Figures 3, 7, 8 have been revised and Figure A.1 has been added. d) Tables 1, 3, 4 and 5 have been added. e) Clause 7 “Classification” has been extended. f) Annex D “Flow chart of test procedure” has been revised. g) The bibliography has been extended. Previous editions DIN EN 179: 1997

9、-11, 2002-06 EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 179January 2008ICS 91.190 Supersedes EN 179:1997 English VersionBuilding hardware - Emergency exit devices operated by a leverhandle or push pad, for use on escape routes - Requirementsand test methodsQuincaillerie pour le btiment - Ferm

10、etures durgence pourissues de secours manuvres par une bquille ou uneplaque de pousse, destines tre utilises sur des voiesdvacuation - Exigences et mthodes dessaiSchlsser und Baubeschlge - Notausgangsverschlssemit Drcker oder Stoplatte fr Tren in Rettungswegen -Anforderungen und PrfverfahrenThis Eur

11、opean Standard was approved by CEN on 30 November 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references c

12、oncerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its o

13、wn language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuani

14、a, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All

15、 rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 179:2008: EEN 179:2008 (E) 2 Contents Page Foreword. 4 Introduction 5 1 Scope 7 2 Normative references . 7 3 Terms and definitions. 7 4 Requirements 11 4.1 Design requirements 11 4.2 Performan

16、ce requirements 19 4.3 Requirements for product information. 24 5 Tests General and test apparatus 25 5.1 General. 25 5.2 Test apparatus. 26 6 Test methods Procedures. 28 6.1 General. 28 6.2 Test procedure Test sample A Environmental tests. 28 6.3 Test procedure Test sample B Design and performance

17、tests 30 7 Classification. 36 7.1 Category of use (1st character) . 36 7.2 Durability (2nd character) 36 7.3 Door mass (3rd character) . 36 7.4 Suitability for use on fire/smoke doors (4th character) 37 7.5 Safety (5th character) . 37 7.6 Corrosion resistance (6th character) 37 7.7 Security (7th cha

18、racter) 37 7.8 Projection of operating element (8th character) 37 7.9 Type of operation (9th character) 38 7.10 Field of door application (10th character) 38 7.11 Example of classification . 38 8 Marking 39 8.1 On the product 39 8.2 On the packaging 39 8.3 On the installation instructions . 39 8.4 M

19、ortise lock combined with a separate operating element 40 9 Evaluation of conformity 40 DIN EN 179:2008-04 EN 179:2008 (E) 3 9.1 Initial type test . 40 9.2 Sampling, testing and conformity criteria 41 9.3 Factory production control 42 9.4 Periodic testing (for all products) . 46 9.5 Annual testing (

20、for all products) . 47 Annex A (normative) Installation and fixing instructions 48 Annex B (normative) Additional requirements for emergency exit devices intended for use on smoke/fire resisting door assemblies .51 Annex C (normative) Maintenance instructions 53 Annex D (normative) Flow chart of tes

21、t procedure. 54 Annex E (informative) Guidance for choosing relevant product standards for particular exit door applications. 55 Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EU Directive 89/106/EEC, EU Construction Products Directive . 56 Bibli

22、ography . 61 DIN EN 179:2008-04 EN 179:2008 (E) 4 Foreword This document (EN 179:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of

23、a national standard, either by publication of an identical text or by endorsement, at the latest by July 2008, and conflicting national standards shall be withdrawn at the latest by July 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of pate

24、nt rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 179:1997. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential req

25、uirements of EU Directive(s). For relationship with EU Directive 89/106/EEC, see informative Annex ZA which is an integral part of this document. It has been revised to incorporate clarification of the definitions, safety requirements and test procedures, in particular for emergency exit devices int

26、ended for use on double leaf doorsets, in order to allow for more reproducible test methods. It incorporates extension of the classification to avoid misuse of the products, extension of the limits of door mass and dimensions as well as extension of the field of application to cover products already

27、 available on the market, which were not covered by the 1997 edition of this European Standard. It incorporates additional requirements for emergency exit devices intended for use on inwardly opening single leaf exit doors, which are required by the market. However, no other modifications have been

28、made to the original concept and main requirements. A full contribution to the preparation of this European Standard has been made by The European Federation of Associations of Lock and Builders Hardware Manufacturers (ARGE). This European Standard is part of a group of standards dedicated to buildi

29、ng hardware products. It is one of a group of standards for exit devices and exit systems developed by Technical Committee CEN/TC 33. Wherever reference is made to classes, they are considered to be technical classes and not classes according to Article 3(2) of the Construction Products Directive (8

30、9/106/EEC). Verification or tests performed by mechanical test laboratory and fire test laboratory are listed in Table 1 summarizing performance characteristics and compliance criteria. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries

31、 are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, S

32、weden, Switzerland and the United Kingdom. DIN EN 179:2008-04 EN 179:2008 (E) 5 Introduction Experience relating to escape from buildings, fire and/or smoke hazards and general safety has made it desirable that doors in circulation areas, or those that have to be operated in an emergency situation,

33、be fitted with emergency exit devices to common European Standard specifications. The main purpose of the performance requirements contained in this European Standard is to give safe and effective escape through a doorway with one single operation to release the emergency exit device, although this

34、might require prior knowledge of the door situation (e.g. inwardly opening). The performance tests incorporated in this European Standard are considered to be reproducible and, as such, will provide a consistent and objective assessment of the performance of these emergency exit devices. Where panic

35、 situations are foreseen, reference should be made to EN 1125, covering panic exit devices operated by a horizontal bar. See definition 3.18. Where additional security is required for exit doors, reference should be made to prEN 13633 covering electrically controlled panic exit systems, or to prEN 1

36、3637 covering electrically controlled exit systems for use on escape routes. See Bibliography. Due to the wide range of emergency exit devices, the reader is advised to refer to the scope and the detailed contents of this European Standard for coverage but, for information and general guide, this re

37、vised European Standard now deals with: emergency exit devices designed to be used in emergency situations, where people are familiar with the exit and its hardware and therefore a panic situation is most unlikely to develop; emergency exit devices for use on hinged or pivoted door leaves only; rang

38、e of emergency exit devices including those for use on double doorsets (see 7.10); two specific types of operation: emergency exit devices with “lever handle” operation, type A (see 3.9, see Figures 1 and 3) and emergency exit devices with “push pad” operation, type B (see 3.15, see Figures 2 and 4)

39、; two categories of emergency exit device projection in order to maximize the width of the escape route, and minimize the projection from the door face where either or both of these criteria are of importance (see 4.1.12); exceptional case of emergency exit devices intended for use on single leaf in

40、wardly opening exit doors. It is assumed throughout this European Standard that emergency exit doors generally open towards the outside in order to assure safe escape. However, there are cases such as hospital or hotel bedroom doors, classroom doors, etc. where local building regulations allow, by w

41、ay of exception, the exit door to open against the direction of exit; double doorset emergency exit devices of which the first opening leaf is equipped with a panic exit device conforming to EN 1125 and the second opening leaf is equipped with an emergency exit device conforming to EN 179. It is ess

42、ential that this combination undergoes an additional test for approval (see 4.2.4). This European Standard does not cover the following: DIN EN 179:2008-04 EN 179:2008 (E) 6 any particular design of emergency exit devices and only such dimensions as are required for safety reasons are specified; spe

43、cific emergency exit devices intended for use on inwardly opening double doorsets; specific emergency exit devices intended for use by the severely disabled (due to the wide range of disabilities, such emergency exit devices and their performances should be agreed between specifier and producer); pa

44、nic exit devices operated by a horizontal bar (see EN 1125) or electrically controlled panic exit systems or electrically controlled exit systems (see prEN 13633 and prEN 13637). DIN EN 179:2008-04 EN 179:2008 (E) 7 1 Scope This European Standard specifies requirements for the manufacture, performan

45、ce and testing of emergency exit devices mechanically operated by either a lever handle or a push pad for the purpose of achieving a safe exit under an emergency situation on escape routes. The suitability of an emergency exit device for use on smoke/fire-resisting door assemblies is determined by f

46、ire performance tests conducted in addition to the performance tests required by this European Standard. Annex B indicates additional requirements for these products. This European Standard covers emergency exit devices, which are either manufactured and placed on the market in their entirety by one

47、 producer, or produced by more than one producer and subsequently placed on the market as a kit in a single transaction. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated

48、 references, the latest edition of the referenced document (including any amendments) applies. EN 1125, Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods EN 1634-1, Fire resistance and smoke control tests for door and shutte

49、r assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for doors and shutter assemblies and openable windows EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies EN 1670:2007, Building hardware - Corrosion resistance - Requirements and test methods EN ISO 9001:2000, Quality management systems - Requirements (ISO 9001:2000) 3 Te

展开阅读全文
相关资源
  • DIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdfDIN EN 818-7-2008 Short link chain for lifting purposes - Safety - Part 7 Fine tolerance hoist chain Grade T (Types T DAT and DT)(includes Amendment A1 2008) Ge.pdf
  • DIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdfDIN EN 1677-3-2008 Components for slings - Safety - Part 3 Forged steel self-locking hooks Grade 8(includes Amendment A1 2008) English version of DIN EN 1677-3 .pdf
  • DIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdfDIN EN 1677-2-2008 Components for slings - Safety - Part 2 Forged steel lifting hooks with latch Grade 8(includes Amendment A1 2008) English version of DIN EN 1.pdf
  • DIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdfDIN EN 1670-2007 Building hardware - Corrosion resistance - Requirements and test methods English version of DIN EN 1670 2007-06《建筑五金器具 耐腐蚀 要求和试验方法》.pdf
  • DIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdfDIN EN 1656-2010 Chemical disinfectants and antiseptics - Quantitative suspension test for the evaluation of bactericidal activity of chemical disinfectants and.pdf
  • DIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdfDIN EN 1230-2-2018 Paper and board intended to come into contact with foodstuffs - Sensory analysis - Part 2 Off-flavour (taint) German version EN 1230-2 2009《用.pdf
  • DIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdfDIN EN 1176-7-2008 Playground equipment and surfacing - Part 7 Guidance on installation inspection maintenance and operation English version of DIN EN 1176-7 20.pdf
  • DIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdfDIN EN 1176-5-2008 Playground equipment and surfacing - Part 5 Additional specific safety requirements and test methods for carousels English version of DIN EN .pdf
  • DIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdfDIN EN 1159-1-2007 Advanced technical ceramics - Ceramic composites - Thermophysical properties - Part 1 Determination of thermal expansion (includes Corrigendu.pdf
  • DIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdfDIN EN 1093-4-2008 Safety of machinery - Evaluation of the emission of airborne hazardous substances - Part 4 Capture efficiency of an exhaust system - Tracer m.pdf