1、April 2009DEUTSCHE NORM English price group 12No part of this standard may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 13.040.20!$W%“1520259www
2、.din.deDDIN EN ISO 16000-15Indoor air (ISO 16000-15:2008)English version of DIN EN ISO 16000-15:2009-04Innenraumluftverunreinigungen Englische Fassung DIN EN ISO 16000-15:2009-04www.beuth.dePart 15: Sampling strategy for nitrogen dioxide (NO2)2This standard has been included in the VDI/DIN Handbook
3、on air quality, Volume 5.Document comprises 23 pagesTeil 15: Probenahmestrategie fr Stickstoffdioxid (NO ) (ISO 16000-15:2008)DIN EN ISO 16000-15:2009-04 2 National foreword International technical regulation pertaining to indoor air This standard has been prepared by Technical Committee ISO/TC 146
4、“Air quality”, Subcommittee SC 6 “Indoor air”, Working Group WG 7 “Measurement and sampling strategy of nitrogen dioxide (NO2)” (Secretariat: DIN, Germany), in collaboration with Technical Committee CEN/TC 264 “Air quality” (Secretariat: DIN, Germany). The responsible German body involved in its pre
5、paration was the Kommission Reinhaltung der Luft (KRdL) im VDI und DIN-Normenausschuss (Commission on Air Pollution Prevention of VDI and DIN Standards Committee), Section IV Umweltmesstechnik. The sampling strategy procedure described in this standard is based on Guideline VDI 4300 Blatt 5 and is i
6、dentical with this, except for the omissions relating to specific German provisions. The DIN Standard corresponding to the International Standard referred to in clause 2 of the EN is as follows: ISO 16000-1 DIN EN ISO 16000-1 National technical regulation pertaining to indoor air General conditions
7、and other aspects to be taken into consideration when planning indoor air measurements are described for individual substances and substance groups in the VDI 4300 series (see also “National Annex NA”). Many of these served as the sole basis for parts of the ISO 16000 series (e.g. ISO 16000-1, ISO 1
8、6000-2, ISO 16000-5, ISO 16000-7, ISO 16000-12 and ISO 16000-15). The specific procedures (sampling, analysis) are described in the VDI 4301 series for individual substances and substance groups. Methods which can be used for both indoor and ambient air measurements are described in further VDI guid
9、elines. Thus the following technical rules dealing with indoor air measurement are available: DIN ISO 16000 series and DIN EN ISO 16000 series: Standards which have been adopted at national level, and VDI 4300 series and VDI 4301 series: Guidelines which have been developed at national level. In add
10、ition to the legal units of measurement, this standard also uses the unit “ppm”. It is important to note that according to the German law on units in metrology, the use of the unit “ppm” is not permitted in official or business communications within Germany. Conversion: 1 mg/m3 = 0,53 ppm at 293 K a
11、nd 1,013 bar. DIN EN ISO 16000-15:2009-04 3 DIN ISO 16000 series and DIN EN ISO 16000 series consist of the following parts, under the general title Indoor air: DIN EN ISO 16000-1, General aspects of sampling strategy DIN EN ISO 16000-2, Sampling strategy for formaldehyde DIN ISO 16000-3, Determinat
12、ion of formaldehyde and other carbonyl compounds Active sampling method DIN ISO 16000-4, Determination of formaldehyde Diffusive sampling method DIN EN ISO 16000-5, Measurement strategy for volatile organic compounds (VOCs) DIN ISO 16000-6, Determination of volatile organic compounds in indoor and t
13、est chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID DIN EN ISO 16000-7, Sampling strategy for determination of airborne asbestos fibre concentrations DIN ISO 16000-8, Determination of local mean ages of air in buildings for characterizing ve
14、ntilation conditions DIN EN ISO 16000-9, Determination of the emission of volatile organic compounds from building products and furnishing Emission test chamber method DIN EN ISO 16000-10, Determination of the emission of volatile organic compounds from building products and furnishing Emission test
15、 cell method DIN EN ISO 16000-11, Determination of the emission of volatile organic compounds from building products and furnishing Sampling, storage of samples and preparation of test specimens DIN EN ISO 16000-12, Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-di
16、oxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs) DIN ISO 16000-13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls and polychlorinated dibenzo-p-dioxins/dibenzofurans Collection on sorbent-backed filters DIN ISO 16
17、000-14, Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) Extraction, clean-up and analysis by high-resolution gas chromatography/mass spectrometry DIN EN ISO 16000-15, Sampling strategy for
18、nitrogen dioxide (NO2) DIN ISO 16000-16, Detection and enumeration of moulds Sampling by filtration DIN ISO 16000-17, Detection and enumeration of moulds Culture-based method DIN ISO 16000-23, Performance test for evaluating the reduction of formaldehyde concentrations by sorptive building materials
19、 DIN ISO 16000-24, Performance test for evaluating the reduction of the concentrations of volatile organic compounds and carbonyl compounds (except formaldehyde) by sorptive building materials DIN ISO 16000-25, Determination of the emission of semi-volatile organic compounds by building products Mic
20、ro-chamber method DIN EN ISO 16000-15:2009-04 4 The following parts are under preparation: DIN ISO 16000-18, Detection and enumeration of moulds Sampling by impaction DIN ISO 16000-19, Sampling strategy for moulds DIN ISO 16000-27, Standard method for the quantitative analysis of asbestos fibres in
21、settled dust DIN ISO 16000-28, Sensory evaluation of emissions from building materials and products The following parts are at the planning stage: DIN ISO 16000-20, Detection and enumeration of moulds Determination of total spore count DIN ISO 16000-21, Detection and enumeration of moulds Sampling f
22、rom materials DIN ISO 16000-22, Detection and enumeration of moulds Molecular methods DIN EN ISO 16000-15:2009-04 5 National Annex NA (informative) Bibliography DIN ISO 12219-1, Indoor air Road vehicles Part 1: Whole vehicle test chamber Specification and method for the determination of volatile org
23、anic compounds in car interiors (under preparation) DIN ISO 12884, Ambient air Determination of total (gas and particle phase) polycyclic aromatic hydrocarbons Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analysis DIN V ENV 13005, Guide to the expression of uncert
24、ainty in measurement DIN EN 14412, Indoor air quality Diffusive samplers for the determination of concentrations of gases and vapours Guide for selection, use and maintenance DIN EN ISO 16017-1, Indoor, ambiant and workplace air Sampling and analysis of volatile organic compounds by sorbent tube/the
25、rmal desorption/capillary gas chromatography Part 1: Pumped sampling DIN EN ISO 16017-2, Indoor, ambient and workplace air Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Part 2: Diffusive sampling DIN ISO 16362, Ambient air Determi
26、nation of particle-phase polycyclic aromatic hydrocarbons by high performance liquid chromatography DIN EN ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories VDI 2464 Blatt 1, Ambient air measurement Indoor air measurement Measurement of polychlorinated bi
27、phynyls (PCBs); GC/MS method for PCB 28, 52, 101, 138, 153, 180 VDI 2464 Blatt 2, Ambient air measurement Indoor air measurement Measurement of polychlorinated biphenyls (PCBs); HR-GC/HR-MS method for coplanar PCBs VDI 3484 Blatt 1, Gaseous ambient air measurements Indoor-air pollution measurements
28、Test gases measurements; Measurement of the formaldehyde concentration with the sulfite pararosaniline method VDI 3484 Blatt 2, Gaseous ambient air measurements Indoor-air pollution measurements Measurement of the formaldehyde concentration with the acatylacetone method VDI 3498 Blatt 1, Ambient air
29、 measurement Indoor air measurement Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using large filters VDI 3498 Blatt 2, Ambient air measurement Indoor air measurement Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using small filters VDI 4300
30、Blatt 1, Indoor-air pollution measurement General aspects of measurement strategy VDI 4300 Blatt 2, Indoor-air pollution measurement Measurement strategy for polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated
31、bibhenyle (PCBs) VDI 4300 Blatt 4, Indoor air pollution measurement Measurement strategy for pentachlorophenol (PCP) and -hexachlorocyclohexane (lindane) in indoor air VDI 4300 Blatt 5, Indoor air pollution measurement Measurement strategy for nitrogen dioxide (NO2) DIN EN ISO 16000-15:2009-04 6 VDI
32、 4300 Blatt 6, Measurement of indoor air pollution Measurement strategy for volatile organic compounds (VOCs) VDI 4300 Blatt 7, Indoor-air pollution measurement Measurement of indoor air change rate VDI 4300 Blatt 8, Measurement of indoor air pollution Sampling of house dust VDI 4300 Blatt 9, Measur
33、ement of indoor air pollution Measurement strategy for carbon dioxide (CO2) VDI 4300 Blatt 10, Measurement of indoor air pollution Measurement strategies for determination of mould fungi in indoor environment VDI 4301 Blatt 1, Indoor air pollution measurement Determination of the concentration of ni
34、trogen dioxide Manual photometric method (Saltzman) VDI 4301 Blatt 2, Indoor air pollution measurement Measurement of pentaclorphenol (PCP) and -hexachlorcyclohexane (lindane) GC/MS-method VDI 4301 Blatt 3, Measurement of indoor air pollution Measurement pentaclorophenol (PCP) and -hexachlorcyclohex
35、ane (lindane) GC/ECD method VDI 4301 Blatt 4, Measurement of indoor air pollution Measurement of pyrethroids and piperonyl butoxide in air, house dust and solvent wipe samples VDI 4301 Blatt 5, Measurement of indoor air pollution Measurement of flame retardants and plasticizers based on phosphor org
36、anic compounds Phosphoric acid ester The following VDI Guidelines are under preparation: VDI 2464 Blatt 3, Messen von Immissionen Messen von Innenraumluft Messen von polybromierten Flammschutzmitteln VDI 4300 Blatt 11, Messen von Innenraumluftverunreinigungen Messstrategie fr Feinstaub VDI 4301 Blat
37、t 6, Messen von Innenraumluftverunreinigungen Messen von Phthalaten EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN ISO 16000-15July 2008ICS 13.040.20English VersionIndoor air - Part 15: Sampling strategy for nitrogen dioxideAir intrieur - Partie 15: Stratgie dchantillonnage du Innenraumluftverunr
38、einigungen - Teil 15:16000-15:2008)This European Standard was approved by CEN on 11 July 2008.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date
39、 lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the re
40、sponsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Ic
41、eland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de St
42、assart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN ISO 16000-15:2008: Edioxyde dazote (NO2) (ISO 16000-15:2008)2(NO2) (ISO 16000-15:2008)Probenahmestrategie fr Stickstoffdioxid (NO ) (ISOContents Page 1 2
43、 3 4 5 5.1 5.2 5.3 5.4 6 6.1 6.2 6.3 6.4 6.5 6.6 6.7 EN ISO 16000-15:2008 (E) 2DIN EN ISO 16000-15:2009-04 Scope 5 Normative references 5 Properties, origin and occurrence of nitrogen dioxide5 Regulations 6 Measurement technique7 Long-term measurements.7 General7 Short-term measurements 7 Measuremen
44、t objective and boundary conditions.8 Measurement planning8 Pre-testing 8 General8 Annex B (informative) Examples of screening tests .14 Bibliography 15 Annex A (informative) Information on diffusive samplers 13 Measurement time .10 Measurement location.11 Sampling period and measurement frequency 1
45、0 Measurement uncertainty and presentation of result11 Quality assurance11 Introduction 4 Foreword. 3 Foreword This document (EN ISO 16000-15:2008) has been prepared by Technical Committee ISO/TC 146 “Air quality“ in collaboration with Technical Committee CEN/TC 264 “Air quality” the secretariat of
46、which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2009, and conflicting national standards shall be withdrawn at the latest by January 2009. Attention is drawn to the p
47、ossibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countrie
48、s are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
49、Sweden, Switzerland and the United Kingdom. Endorsement notice The text of ISO 16000-15:2008 has been approved by CEN as a EN ISO 16000-15:2008 without any modification. EN ISO 16000-15:2008 (E) 3DIN EN ISO 16000-15:2009-04 Introduction In ISO 16000-1, general requirements relating to the measurement of indoor air pollutants and the important conditions to be observed before or during the sa