1、Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: Defense Supply Center, Columbus, ATTN: DSCC-VAT, P.O. Box 3990, Columbus, OH 43218-3990, or email to mailto:CircuitProtectdscc.dla.mil. Since contact info

2、rmation can change you may want to verify the currency of the address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 5925 INCH-POUND A-A-55460D 30 January 2009 SUPERSEDING A-A-55460C October 1, 2003 COMMERCIAL ITEM DESCRIPTION INTERRUPTER, GROUND FAULT, TWO-P

3、OLE, THREE-WIRE HOSPITAL GRADE, 15-AMPERE The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This commercial item description (CID) covers the general requirements for a 15-ampere hospital grade ground fault interrupter.

4、 Ground fault interrupters covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION/PART OR IDENTIFICATION NUMBER (PIN). This CID uses a classification system that is included in the PIN as shown in the following example (see 7.1). AA55460 - S B I CID number Termina

5、tion style (see table I) (S) for screw terminals. (W) for wire leads. Color code (B) Brown (I) Ivory (R) Red (G) Gray (W) White Indicator light (I) for indicator light. Blank for no indicator light. 3. SALIENT CHARACTERISTICS. 3.1 Interface and physical dimensions. Ground fault interrupters supplied

6、 to this CID shall be as specified herein and shall meet the requirements of UL 943 for class A ground fault interrupters and the hospital grade requirements as called out in UL 498 (see figure 1). 3.2. Ampere rating. The ampere rating shall be 15 amperes maximum. 3.3 Voltage rating. The voltage rat

7、ing shall be 125 V ac maximum. 3.4 Frequency rating. The frequency rating shall be 60 Hz. 3.5 Trip threshold. This ground fault interrupter shall trip when a fault current to ground is 4-6 mA minimum. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A

8、-A-55460D 2 NOTES: 1. Dimensions are in inches. 2. Unless otherwise specified, tolerance is .005 inch (0.13 mm). 3. Location of test and/or reset buttons optional and the indicator light is optional. FIGURE 1. Configuration and dimensions. Inches mm 1.229 31.22 1.800 45.72 2.780 70.61 3.280 83.33 3.

9、812 96.82 4.200 106.68 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55460D 3 3.6 Dimensions. Dimensions shall conform to NEMA standard WD 6 (reference NEMA configuration 5-15R) (see figure 1). 3.7 Termination style. The termination style shall

10、 be either screw terminals or wire leads. 3.8 Wire size. The maximum wire size the screw terminal connectors shall accept is number 10 American Wire Gauge (AWG). The minimum wire size of the wire shall be number 14 AWG. 3.9 Wire lead length. The free length of the wire leads shall be 4 inches (101.6

11、 millimeters) minimum. The free length of the ground lead shall be 6 inches (152.4 millimeters) minimum. 3.10 Indicator light. If a yellow indicator light is provided, when lighted it shall indicate the “tripped” condition of the circuit interrupter; when unlighted it shall indicate power availabili

12、ty to the receptacle. 3.11 Marking. Ground fault interrupters or their unit package supplied to this CID shall be marked with the manufacturers (MFRs) standard commercial PIN and the ground fault interrupters shall bear the appropriate UL listing mark. (NOTE: The part number marked on the unit pack

13、shall be the CID PIN.) 3.12 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes

14、economically advantageous life cycle costs. 3.13 Workmanship. Ground fault interrupters shall be processed in such a manner as to be uniform in quality and shall be free from other defects that will affect life, serviceability, or appearance. 4. REGULATORY REQUIREMENTS. The offeror/contractor is enc

15、ouraged to use recovered materials to the maximum extent practicable, in accordance with 23.403 of the Federal Acquisition Regulation (FAR). 5. PRODUCT CONFORMANCE PROVISIONS. 5.1 Product conformance. The products provided shall meet the salient characteristics of this CID, conform to the producers

16、own drawings, specifications, standards, and quality assurance practices, and be the same product offered for sale in the commercial market. The Government reserves the right to require proof of such conformance. 5.2 Market acceptance. The following market acceptance criteria are necessary to docume

17、nt the quality of the product to be provided under this CID: a. The company producing the item must have been producing a product meeting the requirements of this CID for at least 2 years. b. The company must have sold 1,000 units meeting this CID in the commercial marketplace over the past 2 years.

18、 6. PACKAGING. Preservation, packing, and marking shall be as specified in the contract or order. 7. NOTES. 7.1 PIN. The PIN should be used for Government purposes to buy commercial products to this CID. See section 2 for PIN format example. 7.2 Environmentally preferable material. Environmentally p

19、referable materials should be used to the maximum extent possible to meet the requirements of this specification. As of the dating of this document, the U.S. Environmentally Protection Agency (EPA) is focusing efforts on reducing 31 priority chemicals. The list of chemicals is available on their web

20、site at http:/www.epa.gov/osw/hazard/wastemin/priority.htm. Use of these materials on the list should be minimized or eliminated unless needed to meet the requirements specified herein (see Section 3). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

21、A-A-55460D 4 7.3 Commercial and Government Entity (CAGE) code. For ordering purposes, inventory control, and submission of these protectors to DSCC under the Military Parts Control Advisory Group (MPCAG) evaluation program, CAGE code 58536 should be used. 7.4 Source of documents. FEDERAL REGULATIONS

22、 FAR - Federal Acquisition Regulations (FAR). (Copies of this document is available online at http:/www.acquisition.gov/comp/far/index.html from the U.S. Government Printing Office, 732 North Capital Street, NW, Washington D.C. 20401-0001.) Other Publications NATIONAL ELECTRICAL MANUFACTURERS ASSOCI

23、ATION (NEMA) NEMA WD 6 - Wiring Devices - Dimensional Requirements. (Copies of this document are available online at http:/www.nema.org/ or from the National Electrical Manufacturers Association, 1300 North 17THStreet, Suite 1752, Rosslyn, VA 22209-3801.) UNDERWRITERS LABORATORIES, INCORPORATED (UL)

24、 UL 943 - Ground-Fault Circuit-Interrupters, Standard for Safety. (Copies of this document are available online at http:/ or from the Underwriters Laboratories, Incorporated, 333 Pfingsten Road, Northbrook, IL 60062-2096.) (Industry association specifications and standards are generally available fo

25、r reference from libraries. They are also distributed among technical groups and using Federal agencies.) 7.5 Ordering data. The contract or order should specify the following: a. CID document number, revision, and CID PIN. b. Product conformance provisions. c. Packaging requirements. 7.6 Commercial

26、 products. As part of the market analysis and research effort, this CID was coordinated with the following manufacturers of commercial products. At the time of CID preparation and coordination, these manufacturers were known to have commercial products that would meet the requirements of this CID. (

27、NOTE: This information should not be considered as a list of approved manufacturers or be used to restrict procurement to only the manufacturers shown.) MFRs CAGE MFRs name and address 04009 Cooper Industries, Incorporated Cooper Wiring Devices 203 Cooper Circle Peachtree City, GA 30269-3075 Phone n

28、umber: (770) 632-2227 Facsimile number: (770) 632-2268 E-mail: mailto: Uniform Resource Locator (URL): 7.7 Part number (P/N) supersession data. These CID PINs supersede the following MFRs P/Ns as shown. This information is being provided to assist in reducing proliferation in the Government invento

29、ry system. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55460D 5 TABLE II. P/N supersession data. CID dash number AA55460- MFRs CAGE MFRs P/N 1/ SB 04009 N/A SI 04009 N/A SR 04009 N/A SG 04009 N/A SW 04009 N/A SBI 04009 VGFH15B SII 04009 VGFH1

30、5V SRI 04009 VGFH15RD SGI 04009 VGFH15GY SWI 04009 VGFH15WWB 04009 N/A WI 04009 N/A WR 04009 N/A WG 04009 N/A WW 04009 N/A 1/ The manufacturers P/N shall not be used for procurement to the requirements of this CID. At the time of preparation of this CID, the aforementioned commercial products were r

31、eviewed and could be replaced by the CID PIN shown. For actual part marking requirements see 3.10. 7.8 Government users. To acquire information on obtaining these protectors from the Government inventory system, contact Defense Supply Center, Columbus, ATTN: DSCC-FMX, Post Office Box 3990, Columbus,

32、 OH 43218-3990, or telephone (614) 692-3677. 7.9 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extensiveness of the changes. Provided by IHSNot for ResaleNo reproduction or networking permitted without

33、license from IHS-,-,-A-A-55460D 6 MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITY: GSA - FSS Custodians: Navy - EC Preparing activity: DLA - CC DLA-CC Project 5925-2008-004 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-