DLA A-A-55543 C-2011 GUN AIR BLOW (BLAST CLEANING).pdf

上传人:registerpick115 文档编号:686932 上传时间:2018-12-30 格式:PDF 页数:7 大小:47.84KB
下载 相关 举报
DLA A-A-55543 C-2011 GUN AIR BLOW (BLAST CLEANING).pdf_第1页
第1页 / 共7页
DLA A-A-55543 C-2011 GUN AIR BLOW (BLAST CLEANING).pdf_第2页
第2页 / 共7页
DLA A-A-55543 C-2011 GUN AIR BLOW (BLAST CLEANING).pdf_第3页
第3页 / 共7页
DLA A-A-55543 C-2011 GUN AIR BLOW (BLAST CLEANING).pdf_第4页
第4页 / 共7页
DLA A-A-55543 C-2011 GUN AIR BLOW (BLAST CLEANING).pdf_第5页
第5页 / 共7页
点击查看更多>>
资源描述

1、 COMMERCIAL ITEM DESCRIPTION GUN, AIR BLOW, (BLAST CLEANING) The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. This commercial item description (CID) covers the general requirements for gun, air blow, (blast cleaning).

2、Gun, air blow, (blast cleaning) covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION/PART OR IDENTIFICATION NUMBER (PIN). This CID uses a classification system which is included in the PIN as shown in the following example (see 7.1). AA55543 P 2 A T1 CID number

3、Type Class Style Thread size (see table I) (see table I) (see table I) (see table II) AMSC N/A FSC 4940 Comments, suggestions, or questions on this document should be addressed to DLA, Land and Maritime, ATTN: VAI, P.O. Box 3990, Columbus, OH 43218-3990, or email to FluidFlowdla.mil. Since contact i

4、nformation can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil. INCH-POUND A-A-55543C 19 October 2011 SUPERSEDING A-A-55543B 18 October 2005 Provided by IHSNot for ResaleNo reproduction or networking permitted wit

5、hout license from IHS-,-,-A-A-55543C 2 2.1 Classification. TABLE I. Air blow gun type, class, style. Type (see 3.2) Class (lever action) Style Thread size/fitting designator (see table II) L Lever action 1 lever, over A - with hanger B - without hanger T1 T2 T3 2 lever, under P Push-button action 1

6、pushbutton over 2 pushbutton, under G Pistol 3 pistol grip TABLE II. Thread size. Designator Thread Dimension in Inch Dimension in mm T1 1/4 - 18 NPT (internal thread) .250 6.35 T2 3/8 - 18 NPT (internal thread) .375 9.53 T3 1/2 - 18 NPT (external thread) .500 12.70 2.2 Design and construction. Each

7、 air blow gun shall consist of a body, a control valve, and a nozzle having an air opening. The air blow gun shall be capable of providing for the automatic reduction of air in the nozzle to a pressure less than 30 PSI (2.07 bar). The control valve, which shall be easily operable with one hand and a

8、 minimum of hand pressure, shall permit the delivery of air for cleaning purposes in short blasts or in a continuous flow with the valve fully opened. Unless otherwise specified (see 7.2), the nozzle shall be detachable. The air blow gun shall seal completely against the air flow at all operating pr

9、essures. For protection of the operator from chip fly-back, each air blow gun type shall have either a nozzle capable of providing a cone of around the main stream, or a shatter-proof, see-through chip guard attached near the tip (see 7.2). 3. SALIENT CHARACTERISTICS. 3.1 Interface and physical dime

10、nsions. Gun, air blow, (blast cleaning) supplied to this CID shall be as specified herein (see figures 1, 2, and 3). 3.2 Thread size. The air inlets of the guns shall be American Standard Taper Pipe Thread (National Pipe Tapered) (NPT) or Straight Pipe Thread (NPS) as specified on table II. Provided

11、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55543C 3 FIGURE 1. Type I, lever over. FIGURE 2. Type II, push button over. FIGURE 3. Type III, pistol grip design. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from

12、IHS-,-,-A-A-55543C 4 3.3 Type. The guns shall be of three types, as specified below, and as shown on figures 1, 2, and 3 and table I. Figures are for illustration only and are not meant to restrict other designs. 3.3.1 Type L, lever operated guns. 3.3.1.1 Lever over, shall be similar to figure 1. 3.

13、3.2 Type P, push-button operated guns. 3.3.2.1 Push button over, shall be similar to figure 2. 3.3.3 Type G, pistol operated design. 3.3.3.1 Pistol grip design, shall be similar to figure 3. 3.4 Threads. Threads shall be National Pipe Tapered (NPT) in accordance with ASME-B16.15. 3.5 Marking. The ai

14、r blow guns supplied to this CID shall be marked with the manufacturers (MFRs) standard commercial PIN. The part number marked on the unit pack shall be the CID PIN. 4. REGULATORY REQUIREMENTS. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in acco

15、rdance with 23.403 of the Federal Acquisition Regulation (FAR). 4.1 Safety and health requirements. Safety devices shall be provided for the air blow guns where safety hazards are possible. Except as otherwise specified by the procuring activity, the Gun, air blow, (blast cleaning) shall comply with

16、 OSHA 29CFR, standard number 1910.242, and instruction STD 01-13 001, directive #100-1. Exceptions and additional safety and health requirements shall be as specified (see 7.4). 5. PRODUCT CONFORMANCE PROVISIONS. 5.1 Product conformance. The products provided shall meet the salient characteristics o

17、f this CID, conform to the producers own drawings, specifications, standards and quality assurance practices, and be the same product offered for sale in the commercial market. The Government reserves the right to require proof of such conformance. 5.2 Market acceptance. The following market accepta

18、nce criteria are necessary to document the quality of the product to be provided under this CID: a. The company producing the item must have been producing a product meeting the requirements of this CID for at least 2 years. b. The company producing this item must have sold 1,000 units meeting this

19、CID in the commercial marketplace over the past 2 years. 6. PACKAGING. Preservation, packing, and marking shall be as specified in the contract or order. 7. NOTES. 7.1 PIN. The PIN should be used for Government purposes to buy commercial products to this CID. See section 2 for PIN format example. Pr

20、ovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55543C 5 7.2 Environmentally preferable material. Environmentally preferable materials should be used to the maximum extent possible to meet the requirements of this specification. As of the dating of

21、 this document, the U.S. Environmental Protection Agency (EPA) is focusing efforts on reducing 31 priority chemicals. The list of chemicals and additional information is available on their website http:/www.epa.gov/osw/hazard/wastemin/priority.htm. Included in the EPA list of 31 priority chemicals a

22、re cadmium, lead, and mercury. Use of these materials should be minimized or eliminated unless needed to meet the requirements specified herein (see Section 3). 7.3 Commercial and Government Entity (CAGE) code. For ordering purposes, inventory control, and submission of these Gun, air blow, (blast c

23、leaning) to DLA Land and Maritime under the Military Parts Control Advisory Group (MPCAG) evaluation program, CAGE code 58536 should be used. 7.4 Source of documents. FEDERAL REGULATIONS FAR Federal Acquisition Regulations (FAR) (Copies of these documents are available online at www.acquisition.gov/

24、far/current/pdf/far.pdf or from the U.S. Government Printing Office, 732 North Capital Street, NW, Washington D.C. 20401.) Occupational Safety and Health Act OSHA 29CFR - Hand and Portable Powered Tools and Equipment, General OSHA STD 01-13-001 - OSHA Program Directive #100-1, Reduction of Air Press

25、ure Below 30 PSI for Cleaning Purposes (The OSHA Program Directive and Instruction are available online at http:/www.osha.gov or from the Occupational Safety & Health Administration, 200 Constitution Avenue, NW, Washington, DC 20210.) Other Publications ASME INTERNATIONAL ASME-B16.15 - Fitting, Cast

26、 Bronze Threaded, Standard For (Copies of these documents are available online at http:/www.asme.org or from ASME International, Three Park Avenue, New York, NY 10016-5990.) 7.5 Ordering data. The contract or order should specify the following: a. CID document number, revision, and CID number. b. Pr

27、oduct conformance provisions. c. Packaging requirements. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55543C 6 7.6 Commercial products. As part of the market analysis and research effort, this CID was coordinated with the following manufacture

28、rs of commercial products. At the time of CID preparation and coordination, these manufacturers were known to have commercial products that would meet the requirements of this CID. (Note: This information should not be considered as a list of approved manufacturers or be used to restrict procurement

29、 to only the manufacturers shown.) MFRs CAGE MFRs name and address 58277 Coilhose Pneumatics 200 A-Clay Avenue P.O. Box 309 Middlesex, N.J. 08846 (732) 752-5000 14127 Foster MFG. Co., Inc. 2324 W. Battlefield Rd. Springfield, MO 65807-4004 (417) 881-6600 94894 Milton Industries, Inc. 4500 W. Cortlan

30、d Street Chicago, IL 60639-5105 (773) 235-9400 7.7 Part number (P/N) supersession data. These CID PINs supersede the following MFSs P/Ns as shown in table III. This information is being provided to assist in reducing proliferation in the Government inventory system. TABLE III. P/N supersession data.

31、 PIN MFRs CAGE MFRs P/N (PIN) 1/ AA55543-L1BT1 94894 131 AA55543-L1AT1 14127 BG2L-30T AA55543-G3AT1 94894 S160 AA55543- G3AT1 39428 5668K11 AA55543- L1AT1 (less tip) 18876 8455257 2/ 1/ The manufacturers P/N shall not be used for procurement to the requirements of this CID. At the time of preparatio

32、n of this CID, the aforementioned commercial products were reviewed and could be replaced by the CID PIN shown. For actual part marking requirements see 3.3. 2/ CAGE 18876 U.S. Army drawing which lists Foster MFG. (CAGE 14127) PIN BG2L-30T (less tip). 7.8 Government Users. To acquire information on

33、obtaining these air blow guns from the Government inventory system, contact DLA Land and Maritime, ATTN: FMU, P.O. Box 3990, Columbus, OH 43218-3990, or telephone (614) 692-8734. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55543C 7 7.8.1 Nati

34、onal stock number (NSN). The following table IV is a list of NSNs assigned which correspond to this CID. The list is for information only and may not be indicative of all possible NSNs associated with the CID. For up to date information on assigned NSNs, please contact the aforementioned DLA Land an

35、d Maritime office (see 7.8). TABLE IV. NSNs CID PIN PIN listed with NSN NSN AA55543-P-1-B-T2 A-A-55543-2-B 4940-00-223-8970 AA55543-P-1-A-T2 A-A-55543B P 1 A T2 4940-00-223-8972 AA55543-P-1-A-T1 A-A-55543TY 2 CL 1 ST A 4940-00-333-5541 AA55543-P-2-A-T1 A-A-55543-2-A 4940-01-040-7193 AA55543-L-1-A-T1

36、 (less tip) 8455257 4940-01-243-6484 7.9 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extensiveness of the changes. MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITY GSA-FAS Custodians: Army - AR

37、Navy - AS Preparing activity: Air Force - 99 DLA - CC DLA - CC (Project 4940-2011-001) Review activity: Air Force - 84 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN EN 300132-3-1-2013 Environmental Engineering (EE) - Power supply interface at the input to telecommunications and datacom (ICT) equipment - Part 3 Operated by rectified current.pdf DIN EN 300132-3-1-2013 Environmental Engineering (EE) - Power supply interface at the input to telecommunications and datacom (ICT) equipment - Part 3 Operated by rectified current.pdf
  • DIN EN 300132-3-2005 Environmental Engineering (EE) - Power supply interface at the input to telecommunications equipment - Part 3 Operated by rectified current source alternating .pdf DIN EN 300132-3-2005 Environmental Engineering (EE) - Power supply interface at the input to telecommunications equipment - Part 3 Operated by rectified current source alternating .pdf
  • DIN EN 300135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Citizens- Band (CB) radio equipment - Angle-modulated Citizens- Band rad.pdf DIN EN 300135-1-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Citizens- Band (CB) radio equipment - Angle-modulated Citizens- Band rad.pdf
  • DIN EN 300135-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Citizens- Band (CB) radio equipment - Angle-modulated Citizens- Band rad.pdf DIN EN 300135-2-2008 Electromagnetic compatibility and Radio spectrum Matters (ERM) - Land Mobile Service - Citizens- Band (CB) radio equipment - Angle-modulated Citizens- Band rad.pdf
  • DIN EN 300138-1-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service Digital Subscriber Signalling System No one (DSS1) protocol - Part 1.pdf DIN EN 300138-1-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service Digital Subscriber Signalling System No one (DSS1) protocol - Part 1.pdf
  • DIN EN 300138-2-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service - Digital Subscriber Signalling System No one (DSS1) protocol - Part.pdf DIN EN 300138-2-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service - Digital Subscriber Signalling System No one (DSS1) protocol - Part.pdf
  • DIN EN 300138-3-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service - Digital Subscriber Signalling System No one (DSS1) protocol - Part.pdf DIN EN 300138-3-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service - Digital Subscriber Signalling System No one (DSS1) protocol - Part.pdf
  • DIN EN 300138-4-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service Digital Subscriber Signalling System No one (DSS1) protocol - Part 4.pdf DIN EN 300138-4-2000 Integrated Services Digital Network (ISDN) - Closed User Group (CUG) supplementary service Digital Subscriber Signalling System No one (DSS1) protocol - Part 4.pdf
  • DIN EN 300138-5-2002 Integrated Services Digital Network (ISDN) - Digital Subscriber Signalling System No one (DSS1) protocol Closed User Group (CUG) supplementary service - Part 5.pdf DIN EN 300138-5-2002 Integrated Services Digital Network (ISDN) - Digital Subscriber Signalling System No one (DSS1) protocol Closed User Group (CUG) supplementary service - Part 5.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1