1、 AMSC N/A FSC 9150 Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to: STDZNMGTdla.mil or mailed to Defense Supply Center Richmond, ATTN: DSCR-VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616. Since

2、 contact information can change, you may want to verify the currency of this address information using the ASSIST database at http:/assist.daps.dla.mil. A-A-59173A 29 October 2009 SUPERSEDING A-A-59173 4 March 1998 COMMERCIAL ITEM DESCRIPTION GREASE, SILICONE The General Service Administration has a

3、uthorized the use of this commercial item description, for all federal agencies. 1. SCOPE. This commercial item description (CID) covers two types of silicone greases that are intended for application as a lubricant, a sealant, and as a preservative in missile systems. 2. CLASSIFICATION. The silicon

4、e grease shall conform to the following types and sizes: 2.1 Types. Type I Light consistency. Type II Medium consistency. 2.2 Sizes. Size A 8 ounce (oz) tube. Size B 10 pound (lb) can. Size C 5.3 oz tube. 3. SALIENT CHARACTERISTICS. 3.1 Material. The silicone grease shall have an unctuous (oily, soa

5、py) consistency that is free of lumps, crusts, or granular particles. METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59173A 2 3.2 Penetration. The grease shall have the following penetration when tested in accordance with ASTM D217: type

6、I penetration (tenths of a millimeter) range of 300-340; type II penetration (tenths of a millimeter) range of 260-300. 3.3 Foreign particles. The grease shall have the following foreign particle requirements when tested in accordance with FED-STD-791, Method 3005: a. There shall not be more than 75

7、00 particles that are of size 25 microns or greater per cubic centimeter in the grease. b. There shall not be more than 1600 particles that are of size 75 microns or greater per cubic centimeter in the grease. c. There shall not be any particles that are of size 125 microns or greater in the grease.

8、 3.4 Oxidation stability. The oxygen pressure shall not decrease more than 34.47 kilo-Pascals (kPa) during 50 hours of exposure of the material at a temperature of 150C (302F) when tested in accordance with ASTM D942 (an air bath may be substituted for the oil bath). 3.5 Dropping point. The grease s

9、hall have a dropping point greater than 190C (374F) when tested in accordance with ASTM D566 or ASTM D2265. 3.6 Evaporation. The grease shall not lose greater than 3.0 percent of its original weight by evaporation when tested in accordance with ASTM D2595. 3.7 Bleeding. Type I silicone grease shall

10、not lose greater than 5.0 percent of its original weight by bleeding. Type II silicone grease shall not lose greater than 4.0 percent of its original weight by bleeding. The percentage of bleeding of oil from the material shall be determined in accordance with ASTM D6184 except that the heating of t

11、he entire test assembly will be maintained at 150C (302F) for a duration of 24 hours. 3.8 Solidification. The material shall show no evidence of solidification after exposure for 24 hours at a temperature of -55C (-67F). Evidence of solidification shall be tested in accordance with the following tes

12、t procedure: Put 20 millimeters of grease in a 2.54 centimeter (1 in) diameter test tube. Immerse the test tube in a suitable bath and cool to -55C (-67F) for a period of 24 hours. Remove the sample from the test tube and examine for evidence of solidification such as lumps, crusts or granular parti

13、cles. 4. REGULATORY REQUIREMENTS. The offerer/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR). Feasibility of using recovered materials must be considered for silicone grease with r

14、espect to contamination purposes and meeting the salient characteristics of this commercial item description. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59173A 3 5. QUALITY ASSURANCE PROVISIONS. 5.1 Product conformance. The products provided

15、 shall meet the salient characteristics of this commercial item description, conform to the producers own drawings, specifications, standards, and quality assurance practices, and be the same product offered for sale in the commercial market. The Government reserves the right to require proof of suc

16、h conformance. 5.2 Market acceptability. The following market acceptability criteria are necessary to document the quality of the product provided under this CID. a. The company must have provided the silicone grease, meeting the salient characteristics of this CID, for at least 3 years. b. The comp

17、any must be able to show test data or lab results of meeting the salient characteristics of the silicone grease. c. The company must provide a warranty of replacing the defective items. 6. PACKAGING. Preservation, packing and marking shall be as specified in the contract or order. 7. NOTES. 7.1 Part

18、 identification number (PIN). The following part identification number procedure is for government purposes and does not constitute a requirement for the contractor. A-A-59173 1 A Size: A 8 oz tube B 10 lb can C 5.3 oz tube Type: I Light consistency II Medium consistency Commercial item description

19、number 7.2 Source of documents. 7.2.1 Copies of the Federal Acquisition Regulation (FAR) may be obtained from the U.S. Government Printing Office, 732 North Capital Street NW, Washington, DC 20401-0001 or electronically at www.gpo.gov. Provided by IHSNot for ResaleNo reproduction or networking permi

20、tted without license from IHS-,-,-A-A-59173A 4 7.2.2 Copies of federal standards are available online at http:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094. 7.2.3 Copies of ASTM documents are available

21、from ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 or electronically at www.astm.org. 7.3 Ordering data. Acquisition documents must specify the following: a. Title, number, and date of this document. b. Part identification number (PIN). c. Size of containers and quantit

22、y required. 7.4 National stock numbers (NSNs). The following is a list of NSNs assigned which correspond to this CID. This list may not be indicative of all possible NSNs associated with this document. NSN Type Container size 9150-00-145-0161 I 8 oz tube 9150-01-228-3389 II 5.3 oz tube Custodians: P

23、reparing Activity: Army MI DLA-GS3 Navy OS DLA GS Reviewers: (Project 9150-2009-003) Army CD DLA PS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN 14675 Bb 1-2014 Fire detection and fire alarm systems - Design and operation Supplement 1 Application Note《火灾探测和火警警报系统 设计和操作 补充件1 操作说明书》.pdf DIN 14675 Bb 1-2014 Fire detection and fire alarm systems - Design and operation Supplement 1 Application Note《火灾探测和火警警报系统 设计和操作 补充件1 操作说明书》.pdf
  • DIN 14676-2012 Smoke alarm devices for use in residential buildings apartments and rooms with similar purposes - Installation use and maintenance《居民住宅 公寓和类似用途房屋用烟雾报警探测器 安装 使用和维修》.pdf DIN 14676-2012 Smoke alarm devices for use in residential buildings apartments and rooms with similar purposes - Installation use and maintenance《居民住宅 公寓和类似用途房屋用烟雾报警探测器 安装 使用和维修》.pdf
  • DIN 14678-2008 Manual call point (type K) for use in potentially explosive operation rooms by gases or dust《潜在爆炸性气体或灰尘操作房间用手动报警按钮(K型)》.pdf DIN 14678-2008 Manual call point (type K) for use in potentially explosive operation rooms by gases or dust《潜在爆炸性气体或灰尘操作房间用手动报警按钮(K型)》.pdf
  • DIN 14679-2008 Firefighting purposes - Chargers for float charge of starter batteries and auxiliary batteries for special uses - Requirements and testing《消防 专用起动器电池和辅助电池的浮动充电用充电器 要.pdf DIN 14679-2008 Firefighting purposes - Chargers for float charge of starter batteries and auxiliary batteries for special uses - Requirements and testing《消防 专用起动器电池和辅助电池的浮动充电用充电器 要.pdf
  • DIN 14683-2015 Tripod - Collapsable with fixed pivot pin《带固定插销的可折叠三脚架》.pdf DIN 14683-2015 Tripod - Collapsable with fixed pivot pin《带固定插销的可折叠三脚架》.pdf
  • DIN 14685-1-2016 Firefighting and fire protection - Portable generator - Part 1 Generating set = 5kVA《灭火和防火 便携式发电机 第1部分 大于等于5 kVA的发电机组》.pdf DIN 14685-1-2016 Firefighting and fire protection - Portable generator - Part 1 Generating set = 5kVA《灭火和防火 便携式发电机 第1部分 大于等于5 kVA的发电机组》.pdf
  • DIN 14685-2-2016 Firefighting and fire protection - Portable generator - Part 2 Generating set  5 kVA《消防和防火 便携式发电机 第2部分 小于5 kVA的发电机组》.pdf DIN 14685-2-2016 Firefighting and fire protection - Portable generator - Part 2 Generating set 5 kVA《消防和防火 便携式发电机 第2部分 小于5 kVA的发电机组》.pdf
  • DIN 14685-3-2017 Firefighting and fire protection - Portable generator - Part 3 Generating set with inverter = 2 kVA《灭火和防火 便携式发电机 第3部分 带逆变器的发电机组 小于等于2 kVA》.pdf DIN 14685-3-2017 Firefighting and fire protection - Portable generator - Part 3 Generating set with inverter = 2 kVA《灭火和防火 便携式发电机 第3部分 带逆变器的发电机组 小于等于2 kVA》.pdf
  • DIN 14686-2015 Firefighting and fire protection - Switch cabinet for fixed generators (generating set) = 12 kVA in fire-brigade vehicles《灭火和防火 消防车使用大于等于12 kVA的固定发电机 (发电机组) 的开关柜》.pdf DIN 14686-2015 Firefighting and fire protection - Switch cabinet for fixed generators (generating set) = 12 kVA in fire-brigade vehicles《灭火和防火 消防车使用大于等于12 kVA的固定发电机 (发电机组) 的开关柜》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1