1、AMSC N/A FSC 4940 A-A-59436A 5 October 2011 SUPERSEDING A-A-59436 17 September 1999 COMMERCIAL ITEM DESCRIPTION SEPARATORS, OIL AND WATER, COMPRESSED AIR, WALL MOUNTED The General Services Administration has authorized the use of this commercial item description for all federal agencies. 1. SCOPE. T

2、his commercial item description (CID) covers the general requirements for separators, oil and water, compressed air, wall mounted. Separators, oil and water, compressed air, wall mounted covered by this CID are intended for commercial/industrial applications. 2. CLASSIFICATION/PART IDENTIFICATION NU

3、MBER (PIN). This CID uses a classification system which is included in the PIN as shown in the following example (see 7.1). A-A-59436 - 01 CID Number Example: PIN denotes A-A-59436-01 wall mounted oil water, class 1 (one regulator and two air outlets.) TABLE I. Class and configuration. Designator Cl

4、ass Separator configuration -01 Class I One regulator and two air outlets -02 Class II Two regulators and four air outlets Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data that may improve this document should be sent to: DLA Land and Maritime, ATTN: VAI

5、, P.O. Box 3990, Columbus OH 43218-3990, or email FluidFlowdla.mil. Since contact information can change you may want to verify the currency of the address information using the ASSIST Online database at https:/assist.daps.dla.mil/. INCH-POUND Class (see table I). Provided by IHSNot for ResaleNo rep

6、roduction or networking permitted without license from IHS-,-,-A-A-59436A 2 3. SALIENT CHARACTERISTICS 3.1 Interface and physical dimensions. Separators, oil and water, compressed air, wall mounted supplied to this CID shall be as specified herein. 3.2 Components. a. Class I separator shall be a hea

7、d, a filtering unit, a reservoir, a drain valve, a pressure regulator, a regulated air pressure gauge, at least one regulated filtered air outlet valve, an unregulated air pressure gauge, and one supply line pressure filtered air outlet valve with necessary fittings. b. Class II separator shall have

8、 two pressure regulators, two regulated air pressure gauges, one unregulated air pressure gauge, a minimum of four air outlet valves (at least two of which will be for regulated filtered air and at least one of which will be for supply line pressure, filtered air), and the necessary fittings. 3.2.1

9、Filtering unit. The filtering unit shall be made of corrosion-resistant material. The filter shall be the cleanable or replaceable type capable of removing 10 micron or finer particle contamination. 3.2.2 Separator reservoir. The reservoir shall be made of corrosion-resistant material, shall have at

10、 least a one third (1/3) pint capacity, and shall have a valve for removing collected oil and/or water. 3.2.3 Pressure gauges. The pressure gauges shall be in accordance with ANSI B40.100, accuracy grade B. 3.2.4 Inlet and outlet fittings. The separator shall be provided with a female air inlet with

11、 inch NPT thread. All outlet valves shall have -18 NPSH thread, with a tapered seat having a 60 angle included for a female connection. 3.3 Capacity and performance. The capacity and performance requirements stated herein apply to both class I and class II separators unless otherwise indicated. Thes

12、e requirements are summarized in table II. TABLE II. Components, capacity and performance requirements. Requirements Class I Class II Inlet air pressure - 200 psig maximum X X Working temperature - 160F maximum X X Filter element 10 microns X X Cleanable/replaceable filter X X Regulator(s) 1 2 Gauge

13、s 2 3 1/3 pint reservoir X X Drain Valve X X Air passage 20 CFM 60 psig X X Regulated filtered air outlets 1 2 Total number of air outlets 2 4 Inlet fitting inch NPT thread X X Outlet fitting -18NPSH thread X X Corrosion resistant materials X X Provided by IHSNot for ResaleNo reproduction or network

14、ing permitted without license from IHS-,-,-A-A-59436A 3 3.3.1 Class I separator. With an inlet pressure of 100 pound-force per square inch gauge (psig) and regulated pressure of 60 psig, the regulated air pressure gauge shall record a drop of not more than 11 psig when the regulated air outlet valve

15、 is opened to permit air passage at a rate of 20 cubic feet per minute (CFM) free air, for a period of 30 seconds. With the inlet and regulated pressures as stated above, the regulated air pressure gauge shall record a drop of not more than 6 psig when the regulated air outlet valve is opened to per

16、mit air passage at the rate of 11 CFM free air for a period of 30 seconds. 3.3.2 Class II separator. The performance requirements for the class II separator shall be the same as the requirements for the class I separator (3.2.1 above) except that the requirements shall apply to the two regulators, i

17、ndividually, while being operated simultaneously. 3.3.3 Working pressures. The separator assembly and its component parts shall be suitable for use with a maximum working pressure of 200 psig, at a maximum operating temperature of +160F. Each pressure regulator shall be adjustable for delivery of ai

18、r at any pressure from not less than 20 to 100 psig. The differential pressure shall not be more than 5 psig from inlet to outlet over the range of regulation. 3.3.4 Safety and health requirements. The separators shall comply with the general safety and health requirements promulgated under Title 29

19、, Code for Federal Regulations (CFR) Chapter XVII, Part 1910 (http:/www.osha.gov/), which are applicable to the separators themselves. 3.3.5 Protective plugs and caps. Protective plugs and caps shall be installed in the ports and over the threaded connections to prevent damage. 3.4 Marking. Separato

20、rs, oil and water, compressed air, wall mounted supplied to this CID shall be marked with the manufacturers (MFRs) standard commercial PIN. The PIN marked on the unit pack shall be the CID PIN. 3.5 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally

21、preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.6 Workmanship. Separators, oil and water, compressed air, wall mounted shall be proc

22、essed in such a manner as to be uniform in quality and shall be free from other defects that will affect life, serviceability, or appearance. 4. REGULATORY REQUIREMENTS. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with 23.403 of th

23、e Federal Acquisition Regulation (FAR). 5. PRODUCT CONFORMANCE PROVISIONS 5.1 Product conformance. The products provided shall meet the salient characteristics of this CID, conform to the producers own drawings, specifications, standards, and quality assurance practices, and be the same product offe

24、red for sale in the commercial market. The Government reserves the right to require proof of such conformance. 6. PACKAGING Preservation, packing, and marking shall be as specified in the contract or order. 7. NOTES 7.1 PIN. The PIN should be used for Government purposes to buy commercial products t

25、o this CID. See section 2 for PIN format example. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59436A 4 7.2 Environmentally preferable material. Environmentally preferable materials should be used to the maximum extent possible to meet the req

26、uirements of this specification. As of the dating of this document, the U.S. Environmental Protection Agency (EPA) is focusing efforts on reducing 31 priority chemicals. The list of chemicals is available on their website at http:/www.epa.gov/epawaste/hazard/wastemin/index.htm. Included in the EPA l

27、ist of 31 priority chemicals are cadmium, lead, and mercury. Use of the materials on the list should be minimized or eliminated unless needed to meet the requirements specified herein (see section 3). 7.3 Commercial and Government Entity (CAGE) code. For ordering purposes, inventory control, and sub

28、mission of these oil and water separators to DLA Land and Maritime under the Military Parts Control Advisory Group (MPCAG) evaluation program, CAGE code 58536 should be used. 7.4 Source of Documents FEDERAL REGULATION FAR - Federal Acquisition Regulations (FAR) (Copies of these documents are availab

29、le online at www.acquisition.gov/comp/far/index.html or from the U.S. Government Printing Office, 732 North Capital Street, NW, Washington D.C. 20401.) AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI B40.100 - Pressure Gauges and Gauge Attachments (Copies of these documents are available online at

30、 http:/www.ansi.org or from the American National Standard Institute, 25 West 43 Street, 4thFloor, New York, NY 10036.) 7.5 Ordering Data. The contract or order should specify the following: a. CID document number, revision, and CID PIN. b. Product conformance provisions. c. Packaging requirements.

31、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59436A 5 7.6 Commercial products. As part of the market analysis and research effort, this CID was coordinated with the following manufacturers of commercial products. At the time of CID preparation

32、 and coordination, these manufacturers were known to have commercial products that would meet the requirements of this CID. (NOTE: This information should not be considered as a list of approved manufacturers or be used to restrict acquisition to only the manufacturers shown.) Manufacturers name and

33、 address Manufacturers CAGE Fluid-Air Products Inc 12834 Gravois Rd Saint Louis, MO 63127-1713 Tel: (314) 729-7000 5S985 Sharpe Manufacturing Co 8750 Pioneer Blvd. Santa Fe Springs, CA 90670 (310) 908-6800 54360 7.7 Part number (P/N) supersession data. These CID PINs supersede the following MFRs P/N

34、s as shown. This information is being provided to assist in reducing proliferation in the Government inventory system. TABLE III. P/N supersession data. Dash number (see table I) A-A-59436 MFRs CAGE MFRs P/N 1/ MFRs CAGE MFRs P/N 1/ MFRs CAGE MFRs P/N 1/ -01 5S985 606B 17431 HFRL-511 and HAF-408 543

35、60 606B -02 5S985 606C 17431 54360 606C 1/ The manufacturers P/N shall not be used for acquisition to the requirements of this CID. At the time of preparation of this CID, the aforementioned commercial products were reviewed and could be replaced by the CID PIN shown. For actual part marking require

36、ments see 3.5. 7.8 Government users. To acquire information on obtaining these, oil and water, compressed air, wall mounted from the Government inventory system, contact DLA Land and Maritime, ATTN: VAI, P.O. Box 3990, Columbus, OH 432183990, or telephone (614) 692-0565. 7.8.1 National stock number

37、(NSN). The following is a list of NSNs assigned which correspond to this CID. The list is for information only and may not be indicative of all possible NSNs associated with the CID. For up to date information on assigned NSNs, please contact the aforementioned DLA Land and Maritime office (See 7.8)

38、. NSN Class CID PIN 4940-00-215-8496* I and II AA59436-01 and -02 4940-00-242-4100 I AA59436-01 4940-00-242-4101 II AA59436-02 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59436A 6 7.9 Subject term (key word) listing. 10 micron 1/3 pint 200 ps

39、i Drain valve Pressure gauge Life support equipment 7.10 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extensiveness of the changes. MILITARY INTERESTS: CIVIL AGENCY COORDINATING ACTIVITY: Custodians: G

40、SA - FAS Army - AR Navy - MC Preparing activity: Air Force - 99 DLA - CC DLA - CC (Project 4940-2011-003) Review activities: Army - AT Air Force - 84 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-