DLA DSCC-DWG-13011-2013 FILTER EMI HYBRID 28 V dc.pdf

上传人:fuellot230 文档编号:688740 上传时间:2018-12-30 格式:PDF 页数:8 大小:113.57KB
下载 相关 举报
DLA DSCC-DWG-13011-2013 FILTER EMI HYBRID 28 V dc.pdf_第1页
第1页 / 共8页
DLA DSCC-DWG-13011-2013 FILTER EMI HYBRID 28 V dc.pdf_第2页
第2页 / 共8页
DLA DSCC-DWG-13011-2013 FILTER EMI HYBRID 28 V dc.pdf_第3页
第3页 / 共8页
DLA DSCC-DWG-13011-2013 FILTER EMI HYBRID 28 V dc.pdf_第4页
第4页 / 共8页
DLA DSCC-DWG-13011-2013 FILTER EMI HYBRID 28 V dc.pdf_第5页
第5页 / 共8页
点击查看更多>>
资源描述

1、 REVISIONS LTR DESCRIPTION DATE APPROVED Prepared in accordance with ASME Y14.100 REV STATUS REV OF PAGES PAGES 1 2 3 4 5 6 7 8 PMIC N/A PREPARED BY John Bonitatibus DESIGN ACTIVITY DLA LAND AND MARITIME COLUMBUS, OH 43218-3990 Original date of drawing 20 June 2013 CHECKED BY Andrew R. Ernst TITLE F

2、ILTER, EMI, HYBRID, 28 V dc APPROVED BY Michael A. Radecki SIZE A CODE IDENT. NO. 037Z3 DWG NO. 13011 SCALE N/A REV PAGE 1 OF 8 AMSC N/A 5915-2013-E04 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE ID

3、ENT NO. 037Z3 DWG NO. 13011 REV PAGE 2 1. SCOPE 1.1 Scope. This drawing describes the requirements for hybrid microcircuit electromagnetic interference (EMI) suppression filters to be processed in accordance with MIL-PRF-38534. Two product assurance classes consisting of class H (military high relia

4、bility) and class K (space application) and a choice of case outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance (RHA) levels is reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the fo

5、llowing example: 13011 - 01 H X X Drawing RHA Device Device class Case Lead number designator type designator outline finish (see 1.2.1) (see 1.2.2) (see 1.2.3) (see 1.2.4) (see 1.2.5) 1.2.1 Radiation hardness assurance (RHA) designator. Device classes H and K RHA marked devices shall meet the MIL-P

6、RF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device types. The device type identifies the circuit function as follows: Device type Generic number Circuit function 01 SVRMH28, SVRMH28F EMI filter, 28V dc, 2.0 A 1.2

7、.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level as follows: Device class Device requirements documentation K Highest reliability class available. This level is intended for use in space applications. Certification and qualific

8、ation to MIL-PRF-38534 is required. H Standard military reliability level. This level is intended for use in applications where non-space high reliability devices are required. Certification and qualification to MIL-PRF-38534 is required. 1.2.4 Case outline. The case outline shall be as designated i

9、n MIL-STD-1835, and as follows: Outline letter Case outline X 1.460” x 1.130” x .330” (see figure 1) Y 2.000” x 1.130” x .355” (see figure 2) 1.2.5 Lead finish. The lead finish shall be as specified in MIL-PRF-38534 for classes H and K. Finish letter “X“ will not be marked on the filter or its packa

10、ging. The “X“ designation is for use when lead finishes A, B, or C are considered acceptable and interchangeable without preference. 1.3 Absolute maximum ratings. 1/ Input voltage (continuous) - +37.5V dc Input voltage (transient, 1 second) -+50V dc Input current - 2.0 A Power dissipation (Tc = +125

11、C) - 1.0 W Lead temperature (soldering, 10 seconds) - +300 C Storage temperature - -65 C to +150 C 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. Provided by IHSNot for R

12、esaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13011 REV PAGE 3 1.4 Recommended operating conditions. Input voltage - 0V dc to +37.5V dc Case operating temperature range - -55 C to +125 C 2. APPLICABL

13、E DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this drawing. This section does not include documents cited in other sections of this drawing or recommended for additional information or as examples. While every effort has been made to ensure the co

14、mpleteness of this list, document users are cautioned that they must meet all specified requirements of documents in sections 3 and 4 of this drawing, whether or not they are listed here. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standard

15、s, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for. DEP

16、ARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Methods and Procedures for Microelectronics. (Copies of these documents are available online at http:/quicksearch.dla.mil/ or from the Standardization Document Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) 2.3 Order of prec

17、edence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing shall take precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemp

18、tion has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38534 and as specified herein. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-385

19、34 and as specified herein. 3.2.1 Case outline. The case outline shall be in accordance with 1.2.4 herein and figure 1 and figure 2. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1 and figure 2. 3.3 Pure tin prohibition. The use of pure tin as an underplate or

20、final finish in the internal or external construction of the filter and the terminations is prohibited. This includes the discrete devices and solders used internal to the case. Tin shall be alloyed with a minimum of 3 percent lead, by mass. The use of tin alloys other than lead is permissible as sp

21、ecified in appendix E of MIL-PRF-38534. 3.4 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full specified operating temperature range. 3.5 Electrical test requirements. The ele

22、ctrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are defined in table I. 3.6 Marking. Marking shall be in accordance with MIL-PRF-38534. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may al

23、so be marked as listed on QML-38534. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13011 REV PAGE 4 3.7 Manufacturer eligibility. To be eligible for listing as an approved sou

24、rce of supply, the manufacturer shall be certified and qualified to MIL-PRF-38534. In addition to the general requirements of MIL-PRF-38534, the manufacturer of the part described herein shall maintain the electrical test data (variables format) from the initial quality conformance inspection group

25、A lot sample, produced on the certified line, for each device type listed herein. The data should also include a summary of all parameters manually tested, and for those which, if any, are guaranteed. This data shall be maintained under document revision level control by the manufacturer and be made

26、 available to the preparing activity (DLA Land and Maritime-VA) upon request. 3.8 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to supply to this drawing. The certificate of compliance submitted to DLA Land and Maritime-VA shall affirm that the

27、 manufacturers product meets the requirements of MIL-PRF-38534 and the requirements herein. 3.9 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38534 shall be provided with each lot of filters delivered to this drawing. 3.10 Recycled, recovered, or environmentally pre

28、ferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.11 Workmanship. Filters s

29、hall be processed in such a manner as to be uniform in quality and shall be free from cold soldering, corrosion, pits, dents, cracks, rough or sharp edges, misalignments and other defects that will affect life, serviceability, or appearance. TABLE I. Electrical performance characteristics. Test Symb

30、ol Conditions -55C Tc 125C unless otherwise specified Group A subgroup Device types Limits Units Min Max Noise reduction NO f = 500 kHz 1, 2, 3 01 55 - dB DC resistance Rdc1, 2, 3 01 - 250 m Isolation ISO Any pin to case, 500 V dc 1 01 100 - M Capacitance CAP Any pin to case 1, 2, 3 01 10 30 nF Prov

31、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13011 REV PAGE 5 Case outline X Symbol Inches Millimeters Min Max Min Max A - 1.460 - 37.08 B - 1.130 - 28.70 C - .330 - 8.38 D .235

32、.265 5.97 6.73 E .995 1.005 25.27 25.53 F .395 .405 10.03 10.29 G .200 .210 5.08 5.33 J .240 .250 6.10 6.35 K .155 .165 3.94 4.19 H .028 .032 0.71 0.81 NOTES: 1. The case was originally designed using inch-pound units of measurement; in the event of conflict between the metric and inch-pound units,

33、the inch-pound shall take precedence. 2. Device weight: 24 grams maximum. FIGURE 1. Case outline X configuration, dimensions, and terminal connections. Terminal number Function 1 + 28V IN 2 + 28V OUT 3 CASE GROUND 4 OUTPUT COMMON 5 INPUT COMMON Provided by IHSNot for ResaleNo reproduction or network

34、ing permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13011 REV PAGE 6 Case outline Y Symbol Inches Millimeters Min Max Min Max A - 2.000 50.8 B - 1.130 - 28.70 C - .355 - 9.02 D .235 .265 5.97 6.73 E .995 1.005 25.27 25.53 F .395 .405 10

35、.03 10.29 G .200 .210 5.08 5.33 J .240 .250 6.10 6.35 K .155 .165 3.94 4.19 L 1.725 1.735 43.82 44.07 M - 1.460 - 37.08 N .042 .050 1.07 1.27 R .555 .565 14.10 14.35 H .028 .032 0.71 0.81 P .123 .133 3.12 3.38 NOTES: 1. The case was originally designed using inch-pound units of measurement; in the e

36、vent of conflict between the metric and inch-pound units, the inch-pound shall take precedence. 2. Device weight: 29 grams maximum. FIGURE 2. Case outline Y configuration, dimensions, and terminal connections. Terminal number Function 1 + 28V IN 2 + 28V OUT 3 CASE GROUND 4 OUTPUT COMMON 5 INPUT COMM

37、ON Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13011 REV PAGE 7 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with M

38、IL-PRF-38534. 4.2 Screening. Screening shall be in accordance with MIL-PRF-38534. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level contr

39、ol and shall be made available to DLA Land and Maritime-VA or the acquiring activity upon request. Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method 1015 of MIL-STD-883. (2) TAas specified in

40、 accordance with table I of method 1015 of MIL-STD-883. b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. c. PIND testing, method 2020, condition A,

41、of MIL-STD-883. TABLE II. Electrical test requirements MIL-PRF-38534 test requirements Subgroups (in accordance with MIL-PRF-38534, group A test table) Interim electrical parameters Final electrical parameters 1, 2, 3 1/ Group A test requirements 1, 2, 3 Group C end-point electrical parameters 1, 2,

42、 3 End-point electrical parameters for RHA devices Not Applicable 1/ PDA applies to subgroup 1. 4.3 Conformance inspection. Conformance inspection (CI) and periodic inspection (PI) shall be in accordance with MIL-PRF-38534 and as specified herein. 4.3.1 Group A inspection (CI). Group A inspection sh

43、all be in accordance with MIL-PRF-38534 and as follows: a. Tests shall be as specified in table II herein. b. Subgroups 4, 5, 6, 7, 8, 9, 10, and 11 of MIL-PRF-38534, group A shall be omitted. 4.3.2 Group B inspection (PI). Group B inspection shall be in accordance with MIL-PRF-38534. 4.3.3 Group C

44、inspection (PI). Group C inspection shall be in accordance with MIL-PRF-38534 and as follows: a. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test conditions, method 1005 of MIL-STD-883. (1) Test conditions A, B, C, or D. The test circuit shall be ma

45、intained by the manufacturer under document revision level control and shall be made available to DLA Land and Maritime-VA or the acquiring activity upon request. Also, the test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent spe

46、cified in test method 1005 of MIL-STD-883. (2) TAas specified in accordance with table I of method 1005 of MIL-STD-883. (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,

47、-DLA LAND AND MARITIME COLUMBUS, OHIO SIZE A CODE IDENT NO. 037Z3 DWG NO. 13011 REV PAGE 8 4.3.4 Group D inspection (PI). Group D inspection shall be in accordance with MIL-PRF-38534. 4.3.5 Radiation Hardness Assurance (RHA). RHA inspection is not currently applicable to this drawing. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38534. 6. NOTES (This section contains information of a general or explanatory n