DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf

上传人:visitstep340 文档编号:688771 上传时间:2018-12-30 格式:PDF 页数:6 大小:307.46KB
下载 相关 举报
DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf_第1页
第1页 / 共6页
DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf_第2页
第2页 / 共6页
DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf_第3页
第3页 / 共6页
DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf_第4页
第4页 / 共6页
DLA DSCC-DWG-84148 REV E-2005 CONNECTORS PLUGS AND RECEPTACLES ELECTRICAL COAXIAL TWINAXIAL AND TRIAXIAL RADIO FREQUENCY《射频的 双轴和三轴电缆的电子储器和插头的连接器》.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、REV STATUS CHECKED BY Clarence Brezius APPROVEDBY L. Olzsewski SIZE CAGE CODE 03723 REV E A I TITLE CONNECTORS, PLUGS AND RECEPTACLES, ELECTRICAL, COAXIAL, TWINAXIAL AND TRIAXIAL, RADIO FREQUENCY 841 48 DWG. NO. PAGE 1 OF 6 Original date of drawing 5 November 1984 PREPARED BY Ron Gary DEFENSE SUPPLY

2、 CENTER, COLUMBUS 1 COLUMBUS, OHIO 43218-3990 AMSC NIA 5935-E753 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1 .I Scope. This drawing covers the general requirements and tests for radio frequency connectors used with flexible RF cables and certai

3、n other types of coaxial transmission lines. 1.2 Part or Identifvinci Number (PIN). The complete PIN shall be as specified on the requirements drawing and constructed using the following format: xxxxx IL DSCC Connector Material i Finish 4 Cable requirement series (1.2.3) (1.2.4) accommodation s draw

4、ing (1.2.2) (1.2.5) (1.2.1) 1.2.1 DSCC requirements drawing. The DSCC requirements drawing shall state the requirement values and design modifications required of the connectors to be procured by the Government. 1.2.2 Connector series. The connector series shall be identified in the following manner

5、: (Interfaces shall be in accordance with MIL-STD-348.) Desiqnation Series N N C C B BNC T TNC M SMB D SMC S SMA Z Defined on the requirements drawing 1.2.3 Material. Connector body material shall be identified in the following manner: I .2.4 Finish. Connector body finish material shall be identifie

6、d in the following manner: CAGE CODE DWG NO. 03723 841 48 A DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 4321 8-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1 1.2.5 Cable accommodation. Connectors shall accommodate cables as specified in the

7、requirements drawing. Accommodations shall be identified in the following manner: Example: A - -_ MI 7/133-RG405 B - -_-_ M 17/113-RG316 2. APPLICABLE DOCUMENTS 2.1 Government document. 2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part o

8、f this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-3655 MIL-PRF-39012 - Connectors, Coaxial, Radio Frequency, General Specification For. MIL-PRF-49142

9、- Connectors, Triaxial, Radio Frequency, General Specification For. MIL-C-83517 - Connectors, Plug and Receptacle, Electrical (Coaxial Series Twin) and Associated Fittings, General Specification For. - Connector, Coaxial, Radio Frequency for Coaxial, Strip or Microstrip Transmission Line, General Sp

10、ecification For. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Test Methods for Electronic and Electrical Component Parts. MIL-STD-348 - Interface standard, Radio Frequency, Connector, Interfaces For. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/

11、assist.daps.dla.mil or from the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11-5094.) 3. REQUIREMENTS 3.1 DSCC requirements drawing. The individual item requirements shall be in accordance with the applicable specification listed in 2.1, except as spec

12、ified in the requirements drawing and herein. In case of conflict between this drawing and the requirements drawing, the latter shall govern. 3.2 Desiqn, construction. and physical dimensions. The design, construction, and physical dimensions shall be as specified in the applicable specification lis

13、ted in 2.1, except as specified in the requirements drawing and herein. 3.2.1 Desiqn documentation. The design documentation shall be in accordance with the applicable specification listed in 2.1, and unless otherwise specified in the acquisition document, shall be retained by the manufacturer but b

14、e available for review by the contracting activity or contractor upon request. 3.3 Electrical Derformance characteristics. The electrical performance characteristics are as specified in table I and the requirements drawing and apply over the entire operating temperature, unless otherwise specified.

15、3.4 Marking. Marking shall be in accordance with the applicable specification listed in 2.1, except the PIN shall be in accordance with 1.2 herein. CAGE CODE DWG NO. A DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without

16、 license from IHS-,-,-3.5 Quality assurance requirements. Connectors furnished under this drawing shall have been subjected to, and passed all the requirements, tests, and inspections detailed herein including quality conformance inspections. TABLE I. Electrical performance characteristics. Examinat

17、ion or test Examination or test I Requirements value IR Ilnsulation resistance) I 5.000 meaohms Requirement value 3.6 Environmental and mechanical performance characteristics. The environmental and mechanical performance characteristics are as specified in table II. TABLE II. Environmental and mecha

18、nical performance characteristics. Corrosion Durability 48 hrs, 5% salt solution (MIL-STD-202, method 101) 500 cycles 3.7 Qualification. Qualification inspection for connectors specified herein shall not be required. 3.7.1 Qualitv conformance inspection. Quality conformance inspection shall be in ac

19、cordance with the applicable specification listed in 2.1 and 4.3 herein. 3.8 Certification as an approved source of supply. In order to be listed as an approved source of supply for connectors manufactured to this drawing, a manufacturer shall: a. Agree to make available to DSCC, upon request, all p

20、ertinent test data on its production of the subject part. b. Provide to DSCC-VAI or its designated agent, upon request, free of change and without obligation, a current production sample from its production of the subject part. c. Meet one of the following criteria: (1) Currently possess part I list

21、ing on the Qualified Products List for the applicable specification listed in section 2.1, for at least one connector series (not necessarily the one for which the acquisition of this drawing is to apply). (2) Be in current production of the subject part. 3.9 Certificate of compliance. A certificate

22、 of compliance shall be required from a manufacturer in order to be listed as an approved source of supply (see 6.6). CAGE CODE DWG NO. 03723 841 48 A DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS

23、-,-,-4. VERIFICATION 4.1 SamDlinq and inspection. Sampling and inspection procedures shall be in accordance with the applicable specification listed in 2.1, except as modified herein. 4.2 Qualification inspection. Qualification inspection for connectors specified herein shall not be required. 4.3 Qu

24、ality conformance inspection. Quality conformance inspection shall be in accordance with the applicable I specification (see 2.1). Groups A and B inspections shall be performed on each inspection lot. Group C shall be performed on a periodic basis in accordance with the applicable specification. Gen

25、eric test data (see 6.4) may be used to satisfy the requirements for group C inspection. Manufacturers shall keep lot records for 3 years (minimum), monitor for compliance to the prescribed procedures, and observe that satisfactory manufacturing conditions and records on lots are maintained for thes

26、e connectors. The records, including as a minimum an attributes summary of all quality conformance inspections conducted on each lot, shall be available for review by customers at all times. 4.4 Group A inspection. Group A inspection shall consist of the tests shown in section 4 of the applicable sp

27、ecification (see 2.1) with values specified in this drawing and the item requirements drawing, as applicable. 4.4.1 Group B inspection. Group B inspection shall consist of the tests shown in section 4 of the applicable specification (see 2.1) with values specified in this drawing and the item requir

28、ements drawing, as applicable. 4.4.2 Grow C inspection. Group C inspection shall consist of the tests shown in section 4 of the applicable specification (see 2.1) with values specified in this drawing and the item requirements drawing, as applicable. 5. PACKAGING 5.1 Packaqing. For acquisition purpo

29、ses, the packaging requirements shall be as specified in the contract or order (see 6.2). When actual packaging of materiel is to be performed by DoD or in- house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging r

30、equirements are maintained by the Inventory Control Points packaging activities within the Military Service or Defense Agency, or within the Military Service System Commands. Packaging data retrieval is available from the managing Military Departments or Defense Agencys automated packaging files, CD

31、-ROM products, or by contacting the responsible packaging activity. 6. NOTES 6.1 Intended use. Connectors conforming to this drawing are intended for use when defense specifications do not exist and qualified military connectors that will perform the required function are not available for OEM appli

32、cations. This drawing is intended exclusively to prevent the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a defense specification exists and the product covered by this drawing has been qualified for listing on the applicable QPL, this drawing wil

33、l be inactivated and will not be used for new design. The qualified product shall be the preferred item for all applications. 6.2 Acquisition requirements. The acquisition document should specify the following: a. Complete PIN (see 1.2). b. Requirements for delivery of one copy of the quality confor

34、mance inspection data pertinent to the connector inspection lot to be supplied with each shipment by the connector manufacturer, if applicable. c. Requirements for certificate of compliance, if applicable. d. Requirements for notification of change of product or process to the contracting activity,

35、if applicable. CAGE CODE DWG NO. 03723 . 841 48 A DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-e. Requirements for packaging and packing. f. Requirements for assembly and assembly tools. 6.3

36、Replaceability. Replaceability is determined as follows: a. Connectors covered by this drawing will replace the same generic connectors covered by a contractor-prepared specification or drawing. b. When a QPL source is established, the part numbered connector specified in the requirement drawing wil

37、l be replaced by the connector in the requirement supersession table. 6.4 Generic test data. Generic test data may be used to satisfy the requirements of 4.4.2. Group C generic test data shall be on date codes no more than one year old, with the same material, design, and manufacturing process. The

38、vendor is required to retain the generic data for a period of not less than 36 months from the date of shipment. 6.5 Comments. Comments on this drawing should be directed to DSCC-VAI, P.O. Box 3990, Columbus, Ohio 43218-3990 or email RFConnectorsdscc.dla.mil or telephone (614) 692-0568, facsimilie (

39、614) 692-6940. 6.6 Certificate of compliance. The certificate of compliance submitted to DSCC-VAI, prior to listing as an approved source of supply, shall state that the manufacturers product meets the requirements of the applicable DSCC requirements drawing and as stated herein. 6.7 Requirement dra

40、winus. Requirement drawings associated with this drawing, upon their next revision, shall have the CAGE code and the address changed to reflect DSCC. Existing requirements drawing referencing DESC are to be used in the interim. CAGE CODE DWG NO. 03723 84148 A DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-