1、 REVISIONS LTR DESCRIPTION DATE APPROVED A Modify manufacturers eligibility. 20 January 1987 R. Marbais B Reference update. 17 December 1999 Robert M. Heber C Reference update. 3 November 2005 Richard Taylor Prepared in accordance with ASME-Y14.100REV PAGE REV C C C C C REV STATUS OF PAGES PAGE 1 2
2、3 4 5 PREPARED BY PMIC C Ron Gary DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 CHECKED BY TITLE Jeffrey Bohannon APPROVED BY R. Marbais CABLE, ELECTRICAL, RADIO FREQUENCY, COAXIAL, TWINAXIAL AND TRIAXIAL SIZE CAGE CODE 037Z3 DWG. NO. 86045 Original date of drawing 8 August 1986 A REV C
3、PAGE 1 OF 5 AMSC N/A 6145-E073-000 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 1. SCOPE 1.1 Scope. This drawing covers the general requirements and tests for radio frequency cable used the various types of connectors. 1.2 P
4、art or Identifying Number (PIN). The complete PIN shall be as specified on the item requirements drawing and constructed using the following format: XXXXX XX X XX 1.2.1 DSCC requirements drawing. The DSCC requirements drawing shall state the requirement values and design modification required of the
5、 cable to be procured by the Government. 1.2.2 Cable type. The cable type shall be identified in the following manner: Designation TypeCF Coaxial, flexible DF Twinaxial, flexible TF Triaxial, flexible CS Coaxial, semirigid TS Triaxial, semirigid XX To be defined on requirements drawing 1.2.3 Impedan
6、ce. Cable impedance (in ohms) shall be identified in the following manner: 50, 78, 125, etc. 1.2.4 Jacket material. Cable jacket material shall be identified in the following manner: Designations Jacket materia (type in accordance with MIL-DTL-17)PV Polyvinylchloride (type IIa) PR Polychloroprene ru
7、bber (IV) FB Fiberglass braids (V) SR Silicone rubber (VI) PT PTFE (VI) EP Extruded PTFE (VIIa) TP PTFE tape (VIIb) FE Extruded FEP (IX) ET ETFE (X) PU Polyurethane (XII) PF PFA (XIII) XX To be defined on requirements drawing 037Z3 86045 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVC
8、 PAGE2 DSCC requirements drawing (1.2.1) Cable type (1.2.2) Impedance (1.2.3) Jacket material (1.2.4) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. 2. APPLICABLE DOCUMENTS 2.1 Government Document. 2.1.1 Specifications, standa
9、rds, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-17 - Cables,
10、 Radio Frequency, Flexible and Semirigid, General Specification For. MIL-DTL-28830 - Cable, Radio Frequency, Coaxial, Semirigid, Corrugated Outer Conductor, General Specification For. (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or http:/assist.daps.dla.m
11、il or from the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 3. REQUIREMENTS 3.1 DSCC requirements drawing. The individual item requirements shall be in accordance with MIL-DTL-17 or MIL-DTL-28830 (as applicable), except as specified in the requ
12、irements drawing and herein. In case of conflict between this drawing and the requirements drawing, the latter shall govern. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-DTL-17 or MIL-DTL-28830 (as applicable), exce
13、pt as specified in the requirements drawing (see 3.1) and herein. 3.2.1 Design documentation. The design documentation shall be in accordance with MIL-DTL-17 or MIL-DTL-28830 (as applicable) and, unless otherwise specified in the acquisition document, shall be retained by the manufacturer but be ava
14、ilable for review by the contracting activity or contractor upon request. 3.3 Electrical performance and environmental/mechanical characteristics. Unless otherwise specified, the electrical performance and environmental/mechanical characteristics are as specified in the requirements drawing (see 3.1
15、) and apply over the entire operating temperature. 3.4 Marking. Marking shall be in accordance with MIL-DTL-17 or MIL-DTL-28830 (as applicable), except the PIN shall be in accordance with 1.2 herein. 3.5 Quality assurance requirements. Cables furnished under this drawing shall have been subjected to
16、, and passed all the requirements, tests, and inspections detailed herein including quality conformance inspections. 3.6 Qualification. Qualification inspection for cables specified herein shall not be required. 3.6.1 Conformance inspection. Conformance inspection shall be in accordance with MIL-DTL
17、-17 or MIL-DTL-28830 (as applicable), and 4.3 herein. 3.7 Certification as an approved source of supply. In order to be listed as an approved source of supply for cables manufactured to DSCC drawings, a manufacturer shall: a. Agree to make available to DSCC, upon request, all pertinent test data on
18、its production of the subject part. 037Z3 86045 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVC PAGE3 b. Provide to DSCC-VAI, or its designated agent, upon request, free of change and without obligation, a current production sample from its production of the subject part. Provided by
19、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. c. Meet one of the following criteria: (1) Currently possess part I listing on Qualified Products List QPL-M17 for at least one cable series (not necessarily the one for which the procurement
20、 of this drawing is to apply); or (2) Be in current production of the subject part. 3.8 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of supply (see 6.6). 4. QUALITY ASSURANCE PROVISIONS 4.1 Sampling and inspe
21、ction. Sampling and inspection procedures shall be in accordance with MIL-DTL-17 or MIL-DTL-28830 (as applicable), except as modified herein. 4.2 Qualification inspection. Qualification inspection for cables specified herein shall not be required. 4.3 Conformance inspection. Conformance inspection s
22、hall be in accordance with MIL-DTL-17 or MIL-DTL-28830 (as applicable). Groups A and B inspections shall be performed on each inspection lot. Group C shall be performed on a periodic basis in accordance with MIL-DTL-17 or MIL-DTL-28830 (as applicable). Generic test data (see 6.4) may be used to sati
23、sfy the requirements for group C inspection. Manufacturers shall keep lot records for 3 years (minimum), monitor for compliance to the prescribed procedures, and observe that satisfactory manufacturing conditions and records on lots are maintained for these cables. The records, including as a minimu
24、m an attributes summary of all conformance inspections conducted on each lot, shall be available for review by customers at all times (see 3.6.1). 4.4 Group A inspection. Group A inspection shall consist of the tests shown in the appropriate table of MIL-DTL-17 or MIL-DTL-28830 (as applicable) with
25、values specified in this drawing and the item requirements drawing, (see 3.1), as applicable. 4.4.1 Group B inspection. Group B inspection shall consist of the tests shown in the appropriate table of MIL-DTL-17 or MIL-DTL-28830 (as applicable) with values specified in this drawing and the item requi
26、rements drawing, (see 3.1), as applicable. 4.4.2 Group C inspection. Group C inspection shall consist of the tests shown in the appropriate table of MIL-DTL-17 or MIL-DTL-28830 (as applicable) with values specified in this drawing and the item requirements drawing, (see 3.1), as applicable (see 6.4)
27、. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-DTL-17. 6. NOTES 6.1 Intended use. Cables conforming to DSCC drawings are intended for use when defense specifications do not exist and qualified military cables that will perform the required f
28、unction are not available for OEM applications. This drawing is intended exclusively to prevent the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a defense specification exists and the product covered by this drawing has been qualified for listing
29、on QPL this drawing will be inactivated and will not be used for new design. The QPL product shall be the preferred item for all applications. 037Z3 86045 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVC PAGE4 Provided by IHSNot for ResaleNo reproduction or networking permitted without
30、 license from IHS-,-,-SIZE CAGE CODE DWG NO. 6.2 Acquisition requirements. The acquisition document should specify the following: a. Complete PIN (see 1.2). b. Requirements for delivery of one copy of the conformance inspection data pertinent to the cable inspection lot to be supplied with each ship
31、ment by the cable manufacturer, if applicable (see 3.6.1). c. Requirements for certificate of compliance, if applicable (see 3.8). d. Requirements for notification of change of product or process to the contracting activity, if applicable. e. Requirements for packaging and packing (see 5.1). 6.3 Rep
32、laceability. Replaceability is determined as follows: a. Cables covered by DSCC drawings will replace the same generic cables covered by a contractor-prepared specification or drawing. b. When a QPL source is established, the PIN cable specified in the requirement drawing will be replaced by the cab
33、le in the requirement drawing supersession table. 6.4 Generic test data. Generic test data may be used to satisfy the requirements of 4.4.2. Group C generic test data shall be on date codes no more than one year old, with the same material, design, and manufacturing process. The vendor is required t
34、o retain the generic data for a period of not less than 36 months from the date of shipment. 6.5 Comments. Comments on this drawing should be directed to http:/RFConnectorsdscc.dla.mil or DSCC-VAI, P.O. Box 3990, Columbus, Ohio 43218-3990 or telephone (614) 692-0568, faxcimile (614) 692-6940. 6.6 Ce
35、rtificate of compliance. The certificate of compliance submitted to DSCC-VAI, prior to listing as an approved source of supply, shall state that the manufacturers product meets the requirements of the applicable DSCC requirements drawing and as stated herein. 037Z3 86045 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVC PAGE5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-