DLA DSCC-DWG-87093 REV A-2001 CONNECTOR RADIO FREQUENCY DUMMY STOWAGE VARIOUS SERIES《连接头 无线电频率(射频) 非装载 各种系列》.pdf

上传人:confusegate185 文档编号:688869 上传时间:2018-12-30 格式:PDF 页数:8 大小:63.53KB
下载 相关 举报
DLA DSCC-DWG-87093 REV A-2001 CONNECTOR RADIO FREQUENCY DUMMY STOWAGE VARIOUS SERIES《连接头 无线电频率(射频) 非装载 各种系列》.pdf_第1页
第1页 / 共8页
DLA DSCC-DWG-87093 REV A-2001 CONNECTOR RADIO FREQUENCY DUMMY STOWAGE VARIOUS SERIES《连接头 无线电频率(射频) 非装载 各种系列》.pdf_第2页
第2页 / 共8页
DLA DSCC-DWG-87093 REV A-2001 CONNECTOR RADIO FREQUENCY DUMMY STOWAGE VARIOUS SERIES《连接头 无线电频率(射频) 非装载 各种系列》.pdf_第3页
第3页 / 共8页
DLA DSCC-DWG-87093 REV A-2001 CONNECTOR RADIO FREQUENCY DUMMY STOWAGE VARIOUS SERIES《连接头 无线电频率(射频) 非装载 各种系列》.pdf_第4页
第4页 / 共8页
DLA DSCC-DWG-87093 REV A-2001 CONNECTOR RADIO FREQUENCY DUMMY STOWAGE VARIOUS SERIES《连接头 无线电频率(射频) 非装载 各种系列》.pdf_第5页
第5页 / 共8页
点击查看更多>>
资源描述

1、REVISIONSLTR DESCRIPTION DATE APPROVEDA Part number and source update. Editorial changes throughout. 14 June 2001 Robert HeberPrepared in accordance with MIL-STD-100REVPAGEREVAAAAAAAAREV STATUSOF PAGES PAGE 12345678PREPARED BYPMIC N/ARon GaryDEFENSE SUPPLY CENTER, COLUMBUSCOLUMBUS, OHIO 43216-5000CH

2、ECKED BY TITLEC. W. KoellerAPPROVED BYRichard MarbaisCONNECTOR, RADIO FREQUENCY, DUMMYSTOWAGE, VARIOUS SERIESSIZE CAGE CODE037Z3DWG. NO.87093Original date ofdrawing10 Aug 1987AREV A PAGE 1 OF 8AMSC N/A 5935-E641-02DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Provi

3、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZECAGE CODE DWG NO.037Z3 87093DEFENSE SUPPLY CENTER, COLUMBUSCOLUMBUS, OH 43216-5000AREVAPAGE2Inches mm Inches mm.015.06.230.2400.381.525.846.10.250.255.365.3756.356.489.279.53PIN A B C D E T (thread) Seri

4、es87093ZBS87093ZSP.99(25.15).96(24.38)1.07(27.18)1.01(25.65).510(12.95).490(12.45).700(17.78).680(17.27).125(3.18).4375-28-UNEF-2A TKNOTES:1. Dimensions are in inches.2. Metric equivalents are given for general information only.3. Metric equivalents are in parenthesis.FIGURE 1. Dummy stowage, series

5、 TK.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZECAGE CODE DWG NO.037Z3 87093DEFENSE SUPPLY CENTER, COLUMBUSCOLUMBUS, OH 43216-5000AREVAPAGE3PIN A B C D E T (thread) Series87093TBS87093TSP.630(16.00).540(13.70).725(18.42).625(15.88).504(12.88)

6、496(12.60).70(17.8).68(17.3).125(3.18).4375-28-UNEF-2A TNCNOTES:1. Dimensions are in inches.2. Metric equivalents are given for general information only.3. Metric equivalents are in parenthesis.FIGURE 2. Dummy stowage, series TNC.Provided by IHSNot for ResaleNo reproduction or networking permitted

7、without license from IHS-,-,-SIZECAGE CODE DWG NO.037Z3 87093DEFENSE SUPPLY CENTER, COLUMBUSCOLUMBUS, OH 43216-5000AREVAPAGE4PIN A B C D E T (thread) Series87093SSP87093SCG.340(8.64).310(7.87).415(10.54).365(9.27).342(8.69).338(8.59).510 max(12.95).102(2.59).250-36-UNS-2A SMANOTES:1. Dimensions are

8、in inches.2. Metric equivalents are given for general information only.3. Metric equivalents are in parenthesis.FIGURE 3. Dummy stowage, series SMA.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZECAGE CODE DWG NO.037Z3 87093DEFENSE SUPPLY CENTER,

9、 COLUMBUSCOLUMBUS, OH 43216-5000AREVAPAGE5PIN A B C D E T (thread) Series87093NBS87093NSP.671(17.04).641(16.28).756(19.20).716(18.19).723(18.36).713(18.11)1.00(25.40).985(25.02).125(3.18).625-24-UNEF-2A NNOTES:1. Dimensions are in inches.2. Metric equivalents are given for general information only.3

10、 Metric equivalents are in parenthesis.FIGURE 4. Dummy stowage, series N.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZECAGE CODE DWG NO.037Z3 87093DEFENSE SUPPLY CENTER, COLUMBUSCOLUMBUS, OH 43216-5000AREVAPAGE6NOTES:1. Dimensions are in inche

11、s.2. Metric equivalents are given for general information only.3. Metric equivalents are in parenthesis.4. Tolerances shall be .015 unless otherwise specified.PIN A B C D E T (thread) Series87093ZBS-187093ZSP-1.865(21.97).835(21.21).960(24.38).910(23.11).720(18.29).714(18.14)1.00(25.40).985(25.02).1

12、25(3.18).6875-24-UNEF-2A SCFIGURE 5. Dummy stowage, series SC.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZECAGE CODE DWG NO.037Z3 87093DEFENSE SUPPLY CENTER, COLUMBUSCOLUMBUS, OH 43216-5000AREVAPAGE7ENGINEERING DATA:Temperature rating: -65C to

13、 +260C.REQUIREMENTS:Dimensions and configurations: See figures 1 through 5.Insulation resistance: Not applicable.Corrosion (salt Spray): Method 101, test condition B, MIL-STD-202. The salt solution concentration shall be 5percent.Special detail: After exposure, hardware shall be washed, shaken, and

14、lightly brushed, as specified in method 101of MIL-STD-202, and then permitted to dry for 24 hours at 40C. Hardware shall then be examined for evidence ofcorrosion and pitting and ease of coupling.Part or Identifying Number (PIN): See table I.Approved sources of supply. Approved sources of supply are

15、 listed herein. Additional sources will be added as theybecome available. The vendors listed on the requirements drawing have agreed to this drawing and a certificate ofcompliance has been submitted to DSCC-VAI.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from

16、 IHS-,-,-SIZECAGE CODE DWG NO.037Z3 87093DEFENSE SUPPLY CENTER, COLUMBUSCOLUMBUS, OH 43216-5000AREVAPAGE8TABLE I. PINsDSCC drawingPIN1/VendorCAGEnumberVendorreferencePIN87093ZBS87093ZSP87093TBS87093TSP87093SSP87093SCG87093NBS87093NSP87093ZBS-187093ZSP-1007957163000A090-0027163000K090-0011263000A090-

17、0001263000K090-0011363000K050-0021363000G050-0011163000A330-0001163000K330-0021963000A330-0011963000K330-0021/ Parts must be purchased to this DSCC PIN to assure thatall performance requirements and tests are met.Vender CAGE Vendor namenumber and address00795 Delta Electronics416 Cabot StreetBeverly, MA 01915Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS EN 50123-7-3-2003 Railway applications - Fixed installations - d c switchgear - Measurement control and protection devices for specific use in d c traction systems - Isolating ve.pdf BS EN 50123-7-3-2003 Railway applications - Fixed installations - d c switchgear - Measurement control and protection devices for specific use in d c traction systems - Isolating ve.pdf
  • BS EN 50124-1-2017 Railway applications Insulation coordination Basic requirements Clearances and creepage distances for all electrical and electronic equipment《轨道交通 绝缘协调 基本要求 所有电气.pdf BS EN 50124-1-2017 Railway applications Insulation coordination Basic requirements Clearances and creepage distances for all electrical and electronic equipment《轨道交通 绝缘协调 基本要求 所有电气.pdf
  • BS EN 50124-2-2017 Railway applications Insulation coordination Overvoltages and related protection《轨道交通 绝缘协调 过电压和相应保护》.pdf BS EN 50124-2-2017 Railway applications Insulation coordination Overvoltages and related protection《轨道交通 绝缘协调 过电压和相应保护》.pdf
  • BS EN 50125-1-2014 Railway applications Environmental conditions for equipment Rolling stock and on-board equipment《轨道交通 设备的环境条件 车辆和车载设备》.pdf BS EN 50125-1-2014 Railway applications Environmental conditions for equipment Rolling stock and on-board equipment《轨道交通 设备的环境条件 车辆和车载设备》.pdf
  • BS EN 50125-3-2003 Railway applications  nEnvironmental nconditions for nequipment  nPart 3 Equipment for signalling and ntelecommunications《轨道交通 设备的环境条件 信号设备和电信设备》.pdf BS EN 50125-3-2003 Railway applications nEnvironmental nconditions for nequipment nPart 3 Equipment for signalling and ntelecommunications《轨道交通 设备的环境条件 信号设备和电信设备》.pdf
  • BS EN 50126-1999 Railway applications - The specification and demonstration of reliability availability maintainability and safety (RAMS)《轨道交通 可靠性、可用性、可维修性和安全性(RAMS)的规范和验证》.pdf BS EN 50126-1999 Railway applications - The specification and demonstration of reliability availability maintainability and safety (RAMS)《轨道交通 可靠性、可用性、可维修性和安全性(RAMS)的规范和验证》.pdf
  • BS EN 50128-2011 Railway applications Communication signalling and processing systems Software for railway control and protection systems《轨道交通 通信 信号和处理系统 铁路控制和保护系统软件》.pdf BS EN 50128-2011 Railway applications Communication signalling and processing systems Software for railway control and protection systems《轨道交通 通信 信号和处理系统 铁路控制和保护系统软件》.pdf
  • BS EN 50129-2003 Railway applications - Communication signalling and processing systems - Safety related electronic systems for signalling《轨道交通 通信、信号传输和处理系统 信号传输用与安全性相关的电子系统》.pdf BS EN 50129-2003 Railway applications - Communication signalling and processing systems - Safety related electronic systems for signalling《轨道交通 通信、信号传输和处理系统 信号传输用与安全性相关的电子系统》.pdf
  • BS EN 50130-4-2011 Alarm systems Electromagnetic compatibility Product family standard Immunity requirements for components of fire intruder hold up CCTV access control and social .pdf BS EN 50130-4-2011 Alarm systems Electromagnetic compatibility Product family standard Immunity requirements for components of fire intruder hold up CCTV access control and social .pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1