DLA DSCC-DWG-94008 REV K-2009 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY SOCKET CONTACT SERIES SMP FOR 047 AND 086 SEMIRIGID CABLES.pdf

上传人:syndromehi216 文档编号:689000 上传时间:2018-12-30 格式:PDF 页数:8 大小:119.23KB
下载 相关 举报
DLA DSCC-DWG-94008 REV K-2009 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY SOCKET CONTACT SERIES SMP FOR 047 AND 086 SEMIRIGID CABLES.pdf_第1页
第1页 / 共8页
DLA DSCC-DWG-94008 REV K-2009 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY SOCKET CONTACT SERIES SMP FOR 047 AND 086 SEMIRIGID CABLES.pdf_第2页
第2页 / 共8页
DLA DSCC-DWG-94008 REV K-2009 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY SOCKET CONTACT SERIES SMP FOR 047 AND 086 SEMIRIGID CABLES.pdf_第3页
第3页 / 共8页
DLA DSCC-DWG-94008 REV K-2009 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY SOCKET CONTACT SERIES SMP FOR 047 AND 086 SEMIRIGID CABLES.pdf_第4页
第4页 / 共8页
DLA DSCC-DWG-94008 REV K-2009 CONNECTOR ELECTRICAL COAXIAL RADIO FREQUENCY SOCKET CONTACT SERIES SMP FOR 047 AND 086 SEMIRIGID CABLES.pdf_第5页
第5页 / 共8页
点击查看更多>>
资源描述

1、REVISIONS LTR DESCRIPTION DATE APPROVED A Add CAGE 82316 as source of supply. 18 January 1995 Randy Larson B Add Dynawave in accordance with NOR 5935-R002-98. 2 December 1997 Robert Heber C Add new RT angle configuration. Increase force to disengage to 5 pounds on full detent. Delete interfaces. 18

2、February 1999 Robert Heber D Delete dimension “.131 DIA” and substitute “.135 DIA. MAX.” 3 May 1999 Robert Heber E PIN and source update. 3 August 2001 Robert Heber F Changes to NOR incorporated 10 September 2002 Robert Heber G Changes to NOR incorporated 17 January 2003 Robert Heber H PIN numbers f

3、or CAGE 00779 updated 18 August 2005 Richard Taylor J Changes to NOR incorporated 1 February 2007 Richard Taylor K Add test pin requirements and reformat. Add source 95077 21 May 2009 Abdonasser M. Abdouni THE ORIGINAL FIRST PAGE OF THIS DRAWING HAS BEEN REPLACED Prepared in accordance with ASME Y10

4、0. REV PAGE REV STATUS OF PAGES REV K K K K K K K K PAGE 1 2 3 4 5 6 7 8 PMIC G PREPARED BY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 Ron Gary Original date of drawing 29 September 1994 CHECKED BY TITLE C. W. Koeller CONNECTOR, ELECTRICAL, COAXIAL, RADIO FREQUENCY, SOCKET CONTACT SER

5、IES SMP FOR .047 AND .086 SEMIRIGID CABLES APPROVED BY Randy Larson SIZE CAGE CODE DWG. NO. 94008 A 037Z3 REV K PAGE 1 OF 8 AMSC N/A 5935-E819-002 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990

6、 SIZE CAGE CODE DWG NO. A 037Z3 94008 REV K PAGE 2 Inches mm .015 0.38 .135 3.43 .265 6.73 PIN Cable accommodation Cable overall diameter 94008ZCG-1 M17/133-RG405 1/ .086 inch 94008ZCG-2 M17/151-00001 1/ .047 inch 1/ These connectors accept all cables listed on the reference specification sheet. NOT

7、ES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. All undimensioned pictorial configurations are for reference purposes only. 4. Special tools shall be required for assembly. Contact manufacturer. FIGURE 1. General configuration for -1 and -2.Provided by IHSNo

8、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 94008 REV K PAGE 3 Inches mm .135 3.43 .205 5.21 .245 6.22 .275 6.99 PIN Cable accommodation Cable overall diameter 94008ZCG-3 M17/1

9、33-RG405 1/ .086 inch 94008ZCG-4 M17/151-00001 1/ .047 inch 1/ These connectors accept all cables listed on the reference specification sheet. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. All undimensioned pictorial configurations are for reference pur

10、poses only. 4. Special tools shall be required for assembly. Contact manufacturer. FIGURE 2. General configuration for -3 and -4. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE D

11、WG NO. A 037Z3 94008 REV K PAGE 4 Inches mm .098 2.50 .131 3.30 .188 4.80 .265 6.70 PIN Cable accommodation Cable overall diameter 94008ZCG-5 M17/133-RG405 1/ .086 inch 94008ZCG-6 M17/151-00001 1/ .047 inch 1/ These connectors accept all cables listed on the reference specification sheet. NOTES: 1.

12、Dimensions are in inches. 2. Metric equivalents are given for information only. 3. All undimensioned pictorial configurations are for reference purposes only. 4. Special tools shall be required for assembly. Contact manufacturer. FIGURE 3. General configuration for -5 and -6. Provided by IHSNot for

13、ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 94008 REV K PAGE 5 ENGINEERING DATA Nominal impedance: 50 ohms Frequency range: DC to 40 GHz. DC to 26.5 GHz (right angle only). RF leakag

14、e: -80 dB to 3 GHz. -65 dB from 3 to 26.5 GHz minimum. Voltage rating: 335 V rms maximum at sea level: 65 V rms at 70,000 feet. Operating temperature: -65C to +165C. REQUIREMENTS (after assembly): (Requirements of drawing 84148 are applicable). Dimensions and configuration: See figures 1, 2, and 3.

15、Mating connector in accordance with figure 2 of 94007. Mating interface: In accordance with MIL-STD-348A. Force to engage: 15 pounds, maximum (full detent shroud in accordance with 94007). Force to disengage: 5 pounds, minimum (full detent shroud in accordance with 94007). Center contact inspection

16、conditions (after heat treat) Oversize test pin: Test pin diameter: .0165 inch +.0001/-.0000 inch. Insertion depth: .065 inch minimum, .070 inch maximum. Number of insertions: 10. Insertion force test: Test pin diameter: .0160 inch +.0001/-.0000 inch. Insertion force: 24 ounces, maximum. Insertion d

17、epth: .055 inch minimum, .065 inch maximum. Withdrawal force test: Test pin diameter: .0140 +0000/-.0001 inch. Withdrawal force: 0.5 ounce, minimum. Insertion depth: .055 inch minimum, .065 inch maximum. Radial misalignment: Not applicable. Axial misalignment: Not applicable. Coupling proof torque:

18、Not applicable. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 94008 REV K PAGE 6 Hermetic seal: Not applicable. Leakage (pressurized connectors): Not applicable.

19、 Center contact retention: 1.5 pounds minimum axial force (right angle only). Radial torque: Not applicable. Voltage standing wave ratio: DC to 18 gigahertz: 1.20:1 maximum. 18 to 26.5 gigahertz: 1.35:1 maximum. 26.5 to 40 gigahertz: 1.7:1 maximum. VSWR procedure. The VSWR shall be measured in accor

20、dance with the following procedure or a method acceptable to the Government. Part should be tested using a Network Analyzer with the Time Domain (TDR) option installed. The recommended network analyzer systems include Hewlett Packard HP 8510. Wiltron 360 or equivalent. The printer/plotter and the co

21、mputer should be any unit compatible to the system. Calibration of the system should be performed using the manufacturers calibration kits and the recommended calibration procedures. The frequency range shall be DC to 40 GHz for 94008ZCG-1 and -2: DC to 26.5 GHz for 94008ZCG -3, -4, -5, and -6. The

22、VSWR calibration test setup shall be verified using the manufacturers verification kits. The calibrated system VSWR shall be less than 1.02 + .001F (F in GHZ). The device under test (DUT) shall be attached to the appropriate cable. An adapter capable of performing to 40 GHz such as M/A Com p/n 2981-

23、2361-02 or CDI p/n 225-135-1cc or 224-135-1cc or equivalent shall be attached to the calibrated test port of the analyzer. The DUT shall be mated to the test adapter. The VSWR of the DUT shall be measured using the procedures described in the manufacturers operating instructions. The time domain sha

24、ll be used to remove the effects of the test adapter. The output shall be generated using the appropriate printer/plotter. Moisture resistance: MIL-STD-202, method 106, except step 7b shall be omitted. Resistance shall be 1,000 megohms within 5 minutes after removal from humidity. Contact resistance

25、 (in milliohms, maximum): Initial Center contact 6.0 Outer contact 2.0 Outer conductor to connector body 0.5 Dielectric withstanding voltage at sea level: 500 V rms minimum. 125 V rms at 70,000 feet. Vibration, high frequency: MIL-STD-202, method 204, test condition D (When mated with full detent sh

26、roud in accordance with 94007). Vibration, random: MIL-STD-202, method 214, test condition F (When mated with full detent shroud in accordance with 94007) duration 15 minutes, minimum. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CE

27、NTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 94008 REV K PAGE 7 Corona level: Altitude: 70,000 feet. 190 V rms, minimum. Insulation resistance: 5,000 megohms minimum when tested in accordance with MIL-PRF-39012. Altitude: Sea level to 70,000 feet. Solderability (when applica

28、ble): Applicable. Shock (specified pulse): MIL-STD-202, method 213, test condition I (When mated with full detent shroud in accordance with 94007). Thermal shock: MIL-STD-202, method 107, test condition B (except high temperature to be +165C or maximum high temperature of cable). RF high potential w

29、ithstanding voltage: 325 V rms minimum at sea level. Frequency: 5 MHz. Leakage current: Not applicable. Cable retention: 30 pounds minimum: 16 inch-ounces torque (94008ZCG-1, -3, and -5). 20 pounds minimum: torque, not applicable (94008ZCG-2, -4, and -6). Coupling mechanism retention force: Not appl

30、icable. Durability: 100 cycles. RF insertion loss: 0.12 Frequency (GHz) dB Part or Identifying Number (PIN): 94008ZCG-X (See figures 1, 2, and 3). Materials: Contacts and adapter housing: Beryllium copper in accordance with ASTM B196, gold plated to a minimum thickness of 50 microinches (1.27 m) in

31、accordance with MIL-DTL-45204, type II, grade C, class 1, over 50 microinches (1.27 m) minimum of nickel in accordance with MIL-DTL-38999, class 1. The Government has determined that the DSCC drawing PINs listed below are interchangeable with Gilbert Engineering Co,s “push on” style RF connectors to

32、 the extent of meeting all of the requirements specified herein. Approved sources of supply. Additional sources will be added as they become available and demonstrate to the Government through testing at this facility that their product meets all the requirements of this drawing and is intermateable

33、 with the approved sources below. The vendors listed on this drawing have reviewed the requirements of this drawing, determined that their products meets all of those requirements and a certificate of compliance has been submitted to DSCC-VAI. Provided by IHSNot for ResaleNo reproduction or networki

34、ng permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 94008 REV K PAGE 8 DSCC drawing PIN 1/ Vendor CAGE number Vendor reference PIN 94008ZCG-1 30990 82316 2J899 00779 95077 P651-135-1CC 0119-925-1 2000-8520-5425 1056522-1 12

35、04-4000 94008ZCG-2 30990 82316 2J899 00779 95077 P651-135-2CC 0119-930-1 2000-4720-5425 1056521-1 1203-4000 94008ZCG-3 30990 82316 2J899 00779 95077 P652-135-1CC 0119-815-1 2001-8520-5444 1056551-1 1214-4001 94008ZCG-4 30990 82316 2J899 00779 95077 P652-135-2CC 0119-845-1 2001-4720-5444 1056550-1 12

36、13-4007 94008ZCG-5 82316 30990 95077 0119-960-1 P652-135-3CC 1214-4002 94008ZCG-6 82316 30990 95077 0119-208-1 P652-135-4CC 1213-4008 1/ Parts must be purchased to this DSCC PIN to assure that all performance requirements and tests are met. Vendor CAGE Vendor name number and address 30990 Carlisle I

37、nterconnect Technologies 2400 Grand Avenue Long Beach, CA 90815 82316 Corning Gilbert, Inc. 5310 W. Camelback Road Glendale, AZ 85301 2J899 Dynawave Incorporated 179 Ward Hill Avenue Haverhill, MA 01835 00779 TYCO Electronics P.O. Box 3608 Harrisburg, PA 17105 95077 SV Microwave, Inc. 2400 Centrepark West Dr. WPB, FL 33409 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS 5664-3 11-1995 Solventless polymerisable resinous compounds used for electrical insulation - Specification for individual materials - Epoxy resin-based coating powders《电绝缘不溶可聚合树.pdf BS 5664-3 11-1995 Solventless polymerisable resinous compounds used for electrical insulation - Specification for individual materials - Epoxy resin-based coating powders《电绝缘不溶可聚合树.pdf
  • BS 5666-2-1980 Methods of analysis of wood preservatives and treated timber - Qualitative analysis《木材防腐剂与防腐处理分析方法 第2部分 定量分析》.pdf BS 5666-2-1980 Methods of analysis of wood preservatives and treated timber - Qualitative analysis《木材防腐剂与防腐处理分析方法 第2部分 定量分析》.pdf
  • BS 5666-3-1991 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservatives and treated timber containing copper chromium arsenic formulati.pdf BS 5666-3-1991 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservatives and treated timber containing copper chromium arsenic formulati.pdf
  • BS 5666-4-1979 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservatives and treated timber containing copper naphthenate《木材防腐剂与防腐处理分析方法.pdf BS 5666-4-1979 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservatives and treated timber containing copper naphthenate《木材防腐剂与防腐处理分析方法.pdf
  • BS 5666-5-1986 Methods of analysis of wood preservatives and treated timber - Determination of zinc naphthenate in preservative solutions and treated timber《木材防腐剂与防腐处理后分析方法 第5部分 防腐.pdf BS 5666-5-1986 Methods of analysis of wood preservatives and treated timber - Determination of zinc naphthenate in preservative solutions and treated timber《木材防腐剂与防腐处理后分析方法 第5部分 防腐.pdf
  • BS 5666-6-1983 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservative solutions and treated timber containing pentachlorophenol pentac.pdf BS 5666-6-1983 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservative solutions and treated timber containing pentachlorophenol pentac.pdf
  • BS 5666-7-1991 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservatives containing bis(tri-n-butyltin)oxide  determination of total tin.pdf BS 5666-7-1991 Methods of analysis of wood preservatives and treated timber - Quantitative analysis of preservatives containing bis(tri-n-butyltin)oxide determination of total tin.pdf
  • BS 5667-1-1979 Specification for continuous mechanical handling equipment - safety requirements - General《连续式机械装卸设备规范 安全性要求 第1部分 总则》.pdf BS 5667-1-1979 Specification for continuous mechanical handling equipment - safety requirements - General《连续式机械装卸设备规范 安全性要求 第1部分 总则》.pdf
  • BS 5667-3-1979 Specification for continuous mechanical handling equipment - safety requirements - Loose bulk materials storage equipment fed by a pneumatic handling system《连续式机械装卸设.pdf BS 5667-3-1979 Specification for continuous mechanical handling equipment - safety requirements - Loose bulk materials storage equipment fed by a pneumatic handling system《连续式机械装卸设.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1