1、 MIL-DTL-13777/4C 13 June 2011 SUPERSEDING MIL-C-13777/4B 15 September 1969 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL 21, 22, 24, 26, 27, 28, AND 32 CONDUCTORS This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements fo
2、r acquiring the product described herein shall consist of this specification sheet and MIL-DTL-13777. REQUIREMENTS: Dimensions and configuration: See applicable figure and design data for the following cable types specified in table I. Design data is specified in table II. TABLE I. Cable types. 2110
3、55 211115S 211345 S221385 240966 241215S 241215 261065S 271100S 280805 321355 In any conflict between the design data and the applicable figure, the design data shall govern. AMSC N/A FSC 6145 Inactive for new design after 1 July 1998. INCH-POUND Provided by IHSNot for ResaleNo reproduction or netwo
4、rking permitted without license from IHS-,-,-MIL-DTL-13777/4C 2 TABLE II. Design data. Design data Type designation 211055 211115S Figure number 1 2 Total wires 21 21 Number of conductors & AWG # 15/#18 6/#12 5/#18S 10/#18 6/#12 Insulation Minimum average thickness 0.015” 0.020” 0.015” 0.020” Spark
5、test voltage 3000 4000 3000 4000 Inspection test voltage 1500 2000 1500 2000 Cabling Layer 1 Filler Filler Layer 2 (a) Number of wires 6 6 (b) AWG # #12 #12 (c) Maximum lay 4.00” 4.00” Layer 3 (a) Number of wires 15 5 10 (b) AWG # #18 #18S #18 (c) Maximum lay 7.00” 7.00” Sheath Number of layers 2 2
6、Total thickness minimum 0.120” 0.120” Minimum OD cable 1.040” 1.100” Maximum OD cable 1.070” 1.130” Maximum weight (lbs./1000ft.) 708 791 See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 3 TABLE II. Design d
7、ata Continued. Design data Type designation 211345 S221385 Figure number 1 3 Total wires 21 22 Number of conductors & AWG # 15/#18 6/#9 3/#8 4/#12 14/#16 Insulation Minimum average thickness 0.015” 0.030” 0.060” 0.020” 0.015” Spark test voltage 3000 4000 7500 4000 3000 Inspection test voltage 1500 2
8、000 5000 2000 1500 Cabling Layer 1 Filler Filler Layer 2 (a) Number of wires 6 6 (b) AWG # #9 3/#8 3/#16 (c) Maximum lay 6.00” Layer 3 (a) Number of wires 15 16 (b) AWG # #18 4/#12 12/#16 (c) Maximum lay 9.00” 6.00” Sheath Number of layers 2 2 Total thickness minimum 0.156” 0.156” Minimum OD cable 1
9、.330” 1.360” Maximum OD cable 1.360” Maximum weight (lbs./1000ft.) 980 See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 4 TABLE II. Design data Continued. Design data Type designation 240966 241215S Figure n
10、umber 4 5 Total wires 24 24 Number of conductors & AWG # 24/#18 12/#18S1/ 12/#18S2/ Insulation Minimum average thickness 0.015” 0.015” Spark test voltage 3000 3000 Inspection test voltage 1500 1500 Cabling Layer 1 (a) Number of wires 2 4 (b) AWG # #18 #18S3/(c) Maximum lay 3.50” Layer 2 (a) Number o
11、f wires 8 8 12 (b) AWG # #18 #18S4/#18S5/(c) Maximum lay 7.00” Layer 3 (a) Number of wires 14 (b) AWG # #18 (c) Maximum lay 4.5” Sheath Number of layers 2 2 Total thickness minimum 0.125” 0.100” Minimum OD cable 0.951” 1.200” Maximum OD cable 0.981” 1.230” See notes at end of table. Provided by IHSN
12、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 5 TABLE II. Design data Continued. Design data Type designation 241215 261065S Figure number 6 7 Total wires 24 26 Number of conductors & AWG # 5/#18 19/#12 5/#18S 6/#18 12/#13 3/#12 Insulation Minimum
13、 average thickness 0.015” 0.020” 0.015” 0.018” Spark test voltage 3000 4000 3000 4000 Inspection test voltage 1500 2000 1500 1800 Cabling Layer 1 Filler (a) Number of wires 2 (b) AWG # #18S6/(c) Maximum lay Layer 2 (a) Number of wires 5 3 6 (b) AWG # #18 #18S #13 (c) Maximum lay 5.00” Layer 3 (a) Nu
14、mber of wires 7 6 6 3 (b) AWG # #12 #18 #13 #12 (c) Maximum lay 6.00” Layer 4 (a) Number of wires 12 (b) AWG # #12 (c) Maximum lay Sheath Number of layers 2 1 Total thickness minimum 0.098” 0.080” Minimum OD cable 1.190” 1.050” Maximum OD cable 1.240” 1.080” Maximum weight (lbs./1000ft.) 750 See not
15、es at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 6 TABLE II. Design data Continued. Design data Type designation 271100S 280805 Figure number 8 9 Total wires 27 28 Number of conductors & AWG # 27/#18 #20 Insulation
16、 Minimum average thickness 0.012” 0.015” Spark test voltage 3000 3000 Inspection test voltage 1500 1500 Cabling Layer 1 (a) Number of wires 3 4 (b) AWG # #18 #20 (c) Maximum lay Layer 2 (a) Number of wires 9 9 (b) AWG # #18 #20 (c) Maximum lay 5.00” Layer 3 (a) Number of wires 15 15 (b) AWG # #18S #
17、20 (c) Maximum lay Sheath Number of layers 2 1 Total thickness minimum 0.109” 0.080” Minimum OD cable 1.085” 0.780” Maximum OD cable 1.115” 0.830” Maximum weight (lbs./1000ft.) 780 See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH
18、S-,-,-MIL-DTL-13777/4C 7 TABLE II. Design data Continued. Design data Type designation 321355 Figure number 10 Total wires 48 Number of conductors & AWG7/# Insulation Minimum average thickness 0.015” Spark test voltage 3000 Inspection test voltage 1500 Cabling Layer 1 Filler Layer 2 (a) Number of wi
19、res 5 (b) AWG # #16 #20 (c) Maximum lay 2.0” Layer 3 (a) Number of wires 11 (b) AWG # #16 #20 (c) Maximum lay 6.5” Sheath Number of layers 2 Total thickness minimum 0.100” Minimum OD cable 1.325” Maximum OD cable 1.385” Maximum weight (lbs./1000ft.) 945 1/ Shielded pairs 2/ Shielded triplets 3/ 2 Sh
20、ielded pairs 4/ 4 Shielded pairs 5/ 4 Shielded triplets 6/ Shielded pairs AWG#18 with 3” Max lay twist 7/ 32 #16 shielded pairs w/16 #20 bare Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 8 FIGURE 1. Cable types (211055, 211345). P
21、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 9 NOTE: Double circle indicates shielded conductors. FIGURE 2. Cable type (211115S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL
22、-DTL-13777/4C 10 FIGURE 3. Cable type (S221385). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 11 FIGURE 4. Cable type(240966). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D
23、TL-13777/4C 12 NOTE: Double shield indicates shielded conductors. FIGURE 5. Cable type (241215S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 13 FIGURE 6. Cable type (241215). Provided by IHSNot for ResaleNo reproduction or netwo
24、rking permitted without license from IHS-,-,-MIL-DTL-13777/4C 14 NOTE: Double circle indicates shielded conductors. FIGURE 7. Cable type (261065S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 15 NOTE: Double circle indicates shie
25、lded conductors. FIGURE 8. Cable type (271100S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 16 FIGURE 9. Cable type (280805). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-
26、DTL-13777/4C 17 FIGURE 10. Cable type (431355). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/4C 18 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issues
27、due to the extensiveness of the changes. Referenced documents. This document references MIL-DTL-13777. CONCLUDING MATERIAL Custodians: Preparing activity: Army AV DLA - CC Navy SH DLA - CC (Project 6145-2011-010) Review activities: Army AR, CR, MI Air Force 85 Note: The activities listed above were
28、interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information using the Assist Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-