1、AMSC N/A FSC 6240 INCH-POUND MIL-DTL-15098/6C 23 August 2010 SUPERSEDING MIL-L-15098/6B 16 December 1977 DETAIL SPECIFICATION SHEET LAMPS, GLOW, INDICATOR, TYPES J3A AND B9A This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acqu

2、iring the product described herein shall consist of this specification sheet and MIL-DTL-15098, “Lamps, Glow, General Specification for“. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only and are based upon 1 inch = 25.4 mm. FIGURE 1. Indicator glow lam

3、p, types J3A and B9A.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15098/6C 2 REQUIREMENTS: Design and configuration: See figure 1 and table I. Vibration: Applicable. Shock: Method II of MIL-DTL-15098. Part number: M15098/6 - (Dash number f

4、rom table I). TABLE I. Dash numbers and characteristics. Dash no. Characteristic 001 002Bulb shape and size T 4-1/2 T 4-1/2 Maximum overall length (inch) 1.500 1.500 Base DCB DCB Electrode shape P3 P3 Distance from end of electrode to end of bulb (inch, nominal) 0.188 0.188 Series resistor Ohms (nom

5、inal) 15,000 30,000 Location External External Characteristic gas Argon Neon Glow color Blue Red Watts (nominal) 0.25 0.25 Application Indicator Indicator Nominal circuit voltage (volts) 120 AC, 150 DC 120 AC Maximum initial starting voltage (volts) In light 85 AC, 120 DC 65 AC, 90 DC Design current

6、 (milliamperes) 3.5 2 Initial light output (lumens) Not applicable 0.10 Average life at design current (hours) Not applicable 7,500 Industry number ANSI J3A B9A Former industry number AR-4 NE-48 CHANGES FROM PREVIOUS ISSUE. Marginal notations are not used in this revision to identify changes with re

7、spect to the previous issue due to the extent of the changes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15098/6C 3 Custodians: Preparing Activity: Army - CR Navy - SH Air Force - 99 DLA - GS DLA - GS2 (Project 6240-2010-008) Review Acti

8、vities: Army - AR, CR4, MI Navy - AS, CG, MC Air Force - 71 DLA - IS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • CAN CSA-C22 2 NO 60601-2-19-2009 Medical electrical equipment - Part 2-19 Particular requirements for the basic safety and essential performance of infant incubators (Second Editio.pdf CAN CSA-C22 2 NO 60601-2-19-2009 Medical electrical equipment - Part 2-19 Particular requirements for the basic safety and essential performance of infant incubators (Second Editio.pdf
  • CAN CSA-C22 2 NO 60601-2-20-2010 Medical electrical equipment - Part 2-20 Particular requirements for the basic safety and essential performance of infant transport incubators (Sec.pdf CAN CSA-C22 2 NO 60601-2-20-2010 Medical electrical equipment - Part 2-20 Particular requirements for the basic safety and essential performance of infant transport incubators (Sec.pdf
  • CAN CSA-C22 2 NO 60601-2-2004 Medical electrical equipment – Part 2-51 Particular requirements for safety including essential performance of recording and analysing single channel .pdf CAN CSA-C22 2 NO 60601-2-2004 Medical electrical equipment – Part 2-51 Particular requirements for safety including essential performance of recording and analysing single channel .pdf
  • CAN CSA-C22 2 NO 60601-2-21-2010 Medical electrical equipment - Part 2-21 Particular requirements for the basic safety and essential performance of infant radiant warmers (Second E.pdf CAN CSA-C22 2 NO 60601-2-21-2010 Medical electrical equipment - Part 2-21 Particular requirements for the basic safety and essential performance of infant radiant warmers (Second E.pdf
  • CAN CSA-C22 2 NO 60601-2-22-2008 Medical electrical equipment – Part 2-22 Particular requirements for basic safety and essential performance of surgical cosmetic therapeutic and di.pdf CAN CSA-C22 2 NO 60601-2-22-2008 Medical electrical equipment – Part 2-22 Particular requirements for basic safety and essential performance of surgical cosmetic therapeutic and di.pdf
  • CAN CSA-C22 2 NO 60601-2-23-2012 Medical electrical equipment - Part 2-23 Particular requirements for the basic safety and essential performance of transcutaneous partial pressure .pdf CAN CSA-C22 2 NO 60601-2-23-2012 Medical electrical equipment - Part 2-23 Particular requirements for the basic safety and essential performance of transcutaneous partial pressure .pdf
  • CAN CSA-C22 2 NO 60601-2-24-2015 Medical Electrical Equipment - Part 2-24 Particular Requirements for the Safety of Infusion Pumps and Controllers (Second Edition).pdf CAN CSA-C22 2 NO 60601-2-24-2015 Medical Electrical Equipment - Part 2-24 Particular Requirements for the Safety of Infusion Pumps and Controllers (Second Edition).pdf
  • CAN CSA-C22 2 NO 60601-2-25-2012 Medical electrical equipment - Part 2-25 Particular requirements for the basic safety and essential performance of electrocardiographs (Second Edit.pdf CAN CSA-C22 2 NO 60601-2-25-2012 Medical electrical equipment - Part 2-25 Particular requirements for the basic safety and essential performance of electrocardiographs (Second Edit.pdf
  • CAN CSA-C22 2 NO 60601-2-26-2014 Medical electrical equipment - Part 2-26 Particular requirements for the basic safety and essential performance of electroencephalographs (Third Ed.pdf CAN CSA-C22 2 NO 60601-2-26-2014 Medical electrical equipment - Part 2-26 Particular requirements for the basic safety and essential performance of electroencephalographs (Third Ed.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1