1、AMSC N/A FSC 5930 INCH-POUND MIL-DTL-15291/14 7 May 2013 DETAIL SPECIFICATION SHEET SWITCHES, ROTARY, SNAP ACTION CLASS 80SR FRONT & REAR MOUNTED, SIDE CONNECTED This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the sw

2、itch described herein shall consist of this specification sheet and MIL-DTL-15291. NOTES 1. Dimensions are in inches. 2. Unless otherwise specified, tolerance is plus or minus 0.015 FIGURE 1 Class 80SR Switch Front View Provided by IHSNot for ResaleNo reproduction or networking permitted without lic

3、ense from IHS-,-,-MIL-DTL-15291/14 2 X+/- .156FIGURE 2 Class 80SR Switch Side View FIGURE 3 Class 80SR Switch Rear View Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15291/14 3 FIGURE 4 Class 80SR Standard Handle Provided by IHSNot for Resa

4、leNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15291/14 4 FIGURE 5 Class 80SR Three Dimensional View (Four Contacts) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15291/14 5 TABLE I. Type and switching charac

5、teristics. 12 1 2 1 24 38 7CIRCUIT AND SPACER CONFIGURATION ROTOR POSITIONS,SPACER LOCATIONS, TERMINAL MARKING AND LOCATIONSON1&2OFF12M15291/14DASH NO.TYPEDESIGNATION-00180SR2A1FIG 180 Ft-Lbs10.079-00280SR3A1FIG 180 Ft-Lbs12.205-00380SR2A1AFIG 180 Ft-Lbs10.079-00480SR3A1AFIG 180 Ft-Lbs12.205-00580SR

6、4F1FIG 180 Ft-Lbs14.331-00680SR6F1FIG 1120 Ft-Lbs18.583-00780SR2S1FIG 180 Ft-Lbs14.331-00880SR2B1FIG 180 Ft-Lbs14.331DETAILREFTORQUEIN-LBSDIM“X”NO 1NO 2NO 3NO 4NO 5NO 6NO 7NO 8NO 91 24 35 63 46 51 28 74356-00980SR2S1AFIG 180 Ft-Lbs14.33143-01080SR2S1BFIG 1120 Ft-Lbs18.583-01180SR2S2FIG 1120 Ft-Lbs22

7、835-01280SR2E1FIG 1120 Ft-Lbs18.583HANDLEORSHAFTPOSITIONNOTES341234561 24 35 6OFF OFFOFF OFFONONOFF OFFON ONOFF8 71 24 35 68 791012 111&2OFF12 ONOFF OFFOFFONOFF OFFOFF127865ONOFF OFFOFFONOFF OFFOFF123456789101112ONOFF OFFON212134 365OFF12OFF OFF7891011121 28 73 46 591016 1511 1214 13Provided by IHS

8、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15291/14 6 REQUIREMENTS: Applicable specification: MIL-DTL-15291 Dimensions and mounting: See figure 1 Switching characteristics: See table I Angle of throw: 90 degrees Switching action: Snap action, reciproca

9、ting Transfer time: 30ms Electrical and endurance ratings: See table II Stop strength (applicable to switches with stops): 15 ft-pounds Vibration: 50 Hz, MIL-STD-167-1 Shock (high impact): High impact, MIL-S-901 Contact resistance: 1.5 milliohms maximum Dielectric withstanding voltage: 3,500 Vrms In

10、sulation resistance: 100 megohms minimum Mounting bolts: (8) inch diameter, length, and headstyle to suit application. Bolts not furnished. Terminal marking: Terminal markings shown in table I locate terminals as viewed from the front of the switch (handle end). Markings shall be stamped on the swit

11、ch body adjacent to the terminals. TABLE II. Electrical and endurance ratings. 1 - Rating based upon one contact per phase. 2 - Rating based upon one contact per polarity. GENERAL INFORMATION: Switches not covered by Specification sheets: Switches which are fabricated from standard parts, as used in

12、 qualified switches, but which do not comply with switches detailed herein with respect to circuit characteristics, switching action, mounting arrangement, and handle details may be acquired under this specification from contractors having qualification approval under this specification. Extended ra

13、tings: Switches detailed herein have been tested and found satisfactory at the extended ratings listed in table III. Reduced life expectancy must be anticipated for switches used at these increased voltage or current levels. Tests under the conditions of table III are not required for qualification

14、acceptance and they are not repeated routinely as for maintenance of qualification. Supplemental evaluations and tests applicable to particular circuit requirements are recommended. Tests Current (amperes) Voltage (volts) Short Circuit Withstand (kA) (t 0.25sec) Electrical Operations (number of oper

15、ations) Test rate (operations per minute) De-energized operations (number of operations) Alternating current (rms)1Direct current2800 800 500 400 100 100 4000 1000 4 2 2000 500 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15291/14 7 TABLE

16、III. Extended RatingsAC60 or400 Hz500 voltsInductive load0.75p.f.Ops4000DC(Allratingsbased upon two polespositive and negativepercircuit.)440voltsInductive load0.75p.f.Ops1000Amp800Amp.400Resistive orlamp loadOps4000Resistive orlamp loadOps1000Amp800Amp.800250 voltsInductive load 0.75p.f.Ops4000115v

17、oltsInductive load 0.75p.f.Ops4000Amp800Amp.800Resistive orlamp loadOps4000Resistive orlamp loadOps4000Amp800Amp.800125 voltsInductive load0.75p.f.Ops400024voltsInductive load0.75p.f.Ops4000Amp800Amp.800Resistive orlamp loadOperations4000Resistive orlamp loadOperations4000Amperes800Amp.800Switching

18、Character-isticsAllAllProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-15291/14 8 Qualification inspection: Qualification inspection shall be performed at a laboratory acceptable to the Government on sample units produced with equipment and pr

19、ocedures normally used in production. Qualification shall consist of the examination and tests specified in table IV. TABLE IV. Qualification Tests. Inspection Requirement per MIL-DTL-15291 Test Method per MIL-DTL-15291 Sample number 1 2 3 General Examination 3.5 and 3.7 4.6 1 1 1 Operation 3.6.1 4.

20、7.1 2 2 2 Stop Strength 3.6.1.2 4.7.1.2 3 Transfer Time 3.6.1.3 4.7.1.3 3 4 3 Salt Spray 3.6.2 4.7.2 4 Vibration Test 3.6.3 4.7.3 5 High-impact Shock 3.6.4 4.7.4 6 Dielectric Withstand 3.6.5 4.7.5 4 5 7 Contact Resistance 3.6.7 4.7.7 5 6 8 AC Endurance 3.6.9 4.7.9.1 6 DC Endurance 3.6.9 4.7.9.2 7 Te

21、mperature Rise 3.6.8 4.7.8 7 Insulation Resistance 3.6.10 4.7.10 8 8 9 Operation 3.6.1 4.7.1 9 9 11 Transfer Time 3.6.1.3 4.7.1.3 10 10 12 General Examination 3.5 4.6 11 11 13 Sample: 1. Type 80SR3A1 2. Type 80SR2A1 3. Type 80SR2S2 Provided by IHSNot for ResaleNo reproduction or networking permitted

22、 without license from IHS-,-,-MIL-DTL-15291/14 9 APPLICATION AND ACQUISITION GUIDE: PIN and type designation cross reference shall be as shown in table V TABLE V. Application and acquisition guide. Referenced Documents: MIL-DTL-15291 MIL-S-901 MIL-STD-167-1 Custodians: Preparing activity: Navy - SH

23、DLA - CC DLA - CC (Project 5930-2013-018) Review Activities: Navy - AS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Onl

24、ine database at https:/assist.dla.mil/ M15291/14 Dash No. Type Designation For new or Existing design For replacement Circuit Configuration -001 -002 -003 -004 -005 -006 -007 -008 -009 -010 -011 -012 80SR2A1 80SR3A1 80SR2A1A 80SR3A1A 80SR4F1 80SR6F1 80SR2S1 80SR2B1 80SR2S1A 80SR2S1B 80SR2S2 80SR2E1

25、X X X X X X X X X X X X A (on-off-on-off) A (on-off-on-off) A (on-off-off-off) A (on-off-off-off) F (off-on 1-on 1 & 2-on 2) F (off-on 1-on 1 & 2-on 2) S (on-off-off-off) B (off-on 1-off-on 2) S (on-off-off-off) S (on-off-off-off) S (on-off-on-off) E (off-on 1-on 2-on 3) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN 12116-2001 Testing of glass - Resistance to attack by a boiling aqueous solution of hydrochloric acid - Method of test and classification《玻璃试验 采用煮沸盐酸水溶液法试验耐冲击性 试验方法和分类》.pdf DIN 12116-2001 Testing of glass - Resistance to attack by a boiling aqueous solution of hydrochloric acid - Method of test and classification《玻璃试验 采用煮沸盐酸水溶液法试验耐冲击性 试验方法和分类》.pdf
  • DIN 1212-1-2003 Step irons with upstand for staggered manhole steps - Part 1 Brickwork and in-situ concrete manhole step irons《人孔直立错列阶梯脚扣 第1部分 砌墙或浇灌混凝土阶梯脚扣》.pdf DIN 1212-1-2003 Step irons with upstand for staggered manhole steps - Part 1 Brickwork and in-situ concrete manhole step irons《人孔直立错列阶梯脚扣 第1部分 砌墙或浇灌混凝土阶梯脚扣》.pdf
  • DIN 1212-2-2003 Step irons with upstand for staggered manhole steps - Part 2 Precast concrete manhole step irons《人孔直立错列阶梯脚扣 第2部分 浇入混凝土预制件的阶梯脚扣》.pdf DIN 1212-2-2003 Step irons with upstand for staggered manhole steps - Part 2 Precast concrete manhole step irons《人孔直立错列阶梯脚扣 第2部分 浇入混凝土预制件的阶梯脚扣》.pdf
  • DIN 1212-3-2010 Step irons with upstand for staggered manhole steps - Part 3 Bolted-on step irons《错列人孔梯用直立式阶梯脚扣 第3部分 螺栓连接的阶梯脚扣》.pdf DIN 1212-3-2010 Step irons with upstand for staggered manhole steps - Part 3 Bolted-on step irons《错列人孔梯用直立式阶梯脚扣 第3部分 螺栓连接的阶梯脚扣》.pdf
  • DIN 1221-1992 Dirt trap for manhole covers《人孔盖的挡渣器》.pdf DIN 1221-1992 Dirt trap for manhole covers《人孔盖的挡渣器》.pdf
  • DIN 12214-1996 Laboratory glassware - Glass tube ends and covers with laboratory flat flange - Dimensions requirements《实验室玻璃仪器 带实验室扁法兰的玻璃管末端和盖 尺寸、要求》.pdf DIN 12214-1996 Laboratory glassware - Glass tube ends and covers with laboratory flat flange - Dimensions requirements《实验室玻璃仪器 带实验室扁法兰的玻璃管末端和盖 尺寸、要求》.pdf
  • DIN 12215-1975 Laboratory glassware glass tube ends for hose connections olives capillary tube ends《玻璃实验仪器 软管连接用玻璃管端 橄榄形和毛细管端》.pdf DIN 12215-1975 Laboratory glassware glass tube ends for hose connections olives capillary tube ends《玻璃实验仪器 软管连接用玻璃管端 橄榄形和毛细管端》.pdf
  • DIN 12216-1975 Laboratory glassware glass tube ends with round thread《实验室玻璃仪器 带圆螺纹的玻璃管端》.pdf DIN 12216-1975 Laboratory glassware glass tube ends with round thread《实验室玻璃仪器 带圆螺纹的玻璃管端》.pdf
  • DIN 12217-2002 Laboratory glassware - Tubes made of borosilicate glass 3 3《实验室玻璃器皿 硼硅酸盐3 3玻璃管》.pdf DIN 12217-2002 Laboratory glassware - Tubes made of borosilicate glass 3 3《实验室玻璃器皿 硼硅酸盐3 3玻璃管》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1