1、AMSC N/A FSC 6145 INCH-POUND MIL-DTL-16878/16D 25 April 2011 SUPERSEDING MIL-DTL-16878/16C 11 August 2000 DETAIL SPECIFICATION SHEET WIRE, ELECTRICAL, CROSSLINKED, MODIFIED POLYETHYLENE (XLPE) INSULATED, 125 C, 3000 VOLTS This specification is approved for use by all Departments and Agencies of the
2、Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-16878. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16878/16D 2 TABLE I. Wire configuration and dimens
3、ions. PIN 1/Wire size Stranding Conductor Conductor diameter (nominal) (inch) Finished wire diameter (inch) Material Coating Min Max M16878/16BDA* 26 1 X 26 Copper Tin .0159 .067 .082 M16878/16BDB* 26 7 X 34 Copper Tin .0190 .070 .085 M16878/16BDE* 26 19 X 38 Copper Tin .0200 .070 .085 M16878/16BEA*
4、 24 1 X 24 Copper Tin .0201 .071 .086 M16878/16BEB* 24 7 X 32 Copper Tin .0240 .075 .090 M16878/16BEE* 24 19 X 36 Copper Tin .0250 .075 .090 M16878/16BFA* 22 1 X 22 Copper Tin .0254 .076 .091 M16878/16BFB* 22 7 X 30 Copper Tin .0300 .081 .098 M16878/16BFE* 22 19 X 34 Copper Tin .0320 .081 .098 M1687
5、8/16BGA* 20 1 X 20 Copper Tin .0320 .083 .098 M16878/16BGB* 20 7 X 26 Copper Tin .0380 .089 .105 M16878/16BGE* 20 19 X 32 Copper Tin .0400 .089 .105 M16878/16BHA* 18 1 X 18 Copper Tin .0403 .091 .106 M16878/16BHB* 18 7 X 28 Copper Tin .0480 .099 .114 M16878/16BHE* 18 19 X 30 Copper Tin .0470 .099 .1
6、14 M16878/16BJA* 16 1 X 16 Copper Tin .0508 .102 .117 M16878/16BJE* 16 19 X 29 Copper Tin .0570 .108 .123 M16878/16BJF* 16 26 X 30 Copper Tin .0600 .111 .125 M16878/16BKA* 14 1 X 14 Copper Tin .0641 .115 .130 M16878/16BKE* 14 19 X 27 Copper Tin .0720 .123 .138 M16878/16BKH* 14 41 X 30 Copper Tin .07
7、60 .127 .142 M16878/16BLE* 12 19 X 25 Copper Tin .0920 .156 .171 M16878/16BLG* 12 37 X 28 Copper Tin .0890 .153 .168 M16878/16BLJ* 12 65 X 30 Copper Tin .0930 .157 .172 M16878/16BMG 10 37 X 26 Copper Tin .1110 .174 .189 M16878/16BNL 8 133 X 29 Copper Tin .1670 .239 .254 M16878/16BNM 8 168 X 30 Coppe
8、r Tin .1690 .239 .254 M16878/16BPL 6 133 X 27 Copper Tin .2100 .283 .298 M16878/16BRL 4 133 X 25 Copper Tin .2680 .346 .366 M16878/16BSL 2 133 X 23 Copper Tin .3550 .415 .435 M16878/16BSP 2 665 X 30 Copper Tin .3420 .415 .435 M16878/16BTN 1 259 X 25 Copper Tin .3780 .468 .488 M16878/16BTR 1 817 X 30
9、 Copper Tin .3820 .468 .488 M16878/16BUN 0 259 X 24 Copper Tin .4240 .518 .538 M16878/16BUS 0 1045 X 30 Copper Tin .4310 .518 .538 M16878/16BWT 00 1330 X 30 Copper Tin .4750 .575 .599 M16878/16BYV 000 1672 X 30 Copper Tin .5350 .657 .681 M16878/16BZW 0000 2109 X 30 Copper Tin .6000 .790 .733 1/ PIN
10、stands for Part or Identifying Number (see figure 2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-16878/16D 3 M16878/ 16 B F E * Military designation Specification sheet Conductor Conductor Conductor Color material size stranding code FIG
11、URE 2. Example of PIN (see MIL-DTL-16878). Configuration and dimensions: See figure 1 and table I Operating voltage: Up to 3000 volts Operating temperature: Up to 125 C Insulation: Crosslinked polyethylene Spark test voltage: 8.0 kV Impulse dielectric test voltage: 12.0 kV, or 8.5 kV using the 3.0 k
12、Hz spark test Dielectric withstanding voltage: 6.0 kV Partial discharge voltage: Required Insulation resistance: IR = K log10D/d Where: IR = Minimum insulation resistance in megohms per 1000 feet at 20 C K = 10,000 D = Maximum average diameter of finished wire d = Conductor diameter Cold bend: Condi
13、tion 4 hours at -551 C (see table II) TABLE II. Cold bend mandrel sizes. Wire size Cold bend mandrel diameter (inches, maximum) 26 through 22 2 20 through 14 3 12, 10 4.5 8 6 6, 4 10 2, 1, 0 18 00, 000, 0000 20 Surface resistance: Not required Heat resistance: Condition at 150 C Heat aging: 25 perce
14、nt change (maximum) in 96 hours at 135 C Insulation tensile strength: 1800 pounds force per square inch (minimum) Insulation elongation: 100 percent (minimum) Partial discharge test: Required Marking and stripe durability: Not required Provided by IHSNot for ResaleNo reproduction or networking permi
15、tted without license from IHS-,-,-MIL-DTL-16878/16D 4 Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issues due to the extensiveness of the changes. Referenced document. This document references MIL-DTL-16878. CONCLUDING
16、 MATERIAL Custodians: Preparing activity: Navy - SH DLA - CC Air Force - 85 DLA - CC (Project 6145-2011-007) Review activity: Navy - AS Note: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information using the Assist Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-