DLA MIL-DTL-17 233 B-2013 CABLES RADIO FREQUENCY FLEXIBLE COAXIAL 72 OHMS LOW NOISE LOW SMOKE ENHANCED INSULATION RESISTANCE.pdf

上传人:postpastor181 文档编号:690044 上传时间:2018-12-30 格式:PDF 页数:6 大小:54.16KB
下载 相关 举报
DLA MIL-DTL-17 233 B-2013 CABLES RADIO FREQUENCY FLEXIBLE COAXIAL 72 OHMS LOW NOISE LOW SMOKE ENHANCED INSULATION RESISTANCE.pdf_第1页
第1页 / 共6页
DLA MIL-DTL-17 233 B-2013 CABLES RADIO FREQUENCY FLEXIBLE COAXIAL 72 OHMS LOW NOISE LOW SMOKE ENHANCED INSULATION RESISTANCE.pdf_第2页
第2页 / 共6页
DLA MIL-DTL-17 233 B-2013 CABLES RADIO FREQUENCY FLEXIBLE COAXIAL 72 OHMS LOW NOISE LOW SMOKE ENHANCED INSULATION RESISTANCE.pdf_第3页
第3页 / 共6页
DLA MIL-DTL-17 233 B-2013 CABLES RADIO FREQUENCY FLEXIBLE COAXIAL 72 OHMS LOW NOISE LOW SMOKE ENHANCED INSULATION RESISTANCE.pdf_第4页
第4页 / 共6页
DLA MIL-DTL-17 233 B-2013 CABLES RADIO FREQUENCY FLEXIBLE COAXIAL 72 OHMS LOW NOISE LOW SMOKE ENHANCED INSULATION RESISTANCE.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、AMSC N/A FSC 6145 MIL-DTL-17/233B 01 August 2013 SUPERSEDING MIL-DTL-17/233A 7 March 2011 DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 72 OHMS, LOW NOISE, LOW SMOKE, ENHANCED INSULATION RESISTANCE This specification is approved for use by all Departments and Agencies of the

2、 Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-17. FIGURE 1. General configuration. TABLE I. Description. Components Construction details Inner conductor Seven strands of tinned, copper wire. Each strand .0159

3、 inch diameter. Overall diameter: .0477 inch + .0020 concentric stranding centered within 10 percent of dielectric diameter. Dielectric core Inner layer Middle layer Outer layer Composite of three layers. Diameter: .295 inch + .007. Type A-5: Semiconducting polyethylene; .003 inch nominal thickness.

4、 Type A-1: Solid polyethylene. Type A-5: Semiconducting polyethylene; .005 inch nominal thickness. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-17/233B 2 TABLE I. Description Continued. Components Construction details Outer cond

5、uctor Outer conductor Single braid of AWG size 34, tinned copper wire. Diameter: .340 inch, maximum. Coverage: 97.7% inch, maximum. Carriers: 24 Ends: 7 Picks/inch: 16.3 +10% Barrier tape A .001 inch thick polyester tape faced with a .002 inch thick layer of aluminum. The tape will be applied with a

6、 50% lap, nominal. Aluminum face toward the outer conductor. Diameter: .350 inch, maximum. Jacket Type XIV, cross linked optional. Diameter: .405 inch +.010. Magnetic shield Single braid, 36 Gage, high permeability Nickel-Iron Alloy in accordance with MIL-N-14411, type 1. Diameter: .455 inch, maximu

7、m. Coverage: 85% inch, minimum. Carriers: 24 Ends: 8 Picks/Inch: 13.5 Barrier tape A .001 inch thick polyester tape faced with a.002 inch thick layer of aluminum. The tape will be applied with a 50% lap, nominal. Aluminum face toward the magnetic shield. Diameter: .475 inch maximum. Overall jacket T

8、ype XIV, cross linked polyolefin. Thickness, .050 inch, minimum. Diameter: .560 inch, maximum. ENGINEERING INFORMATION: Continuous working voltage: 3,700 V rms, maximum. Operating frequency: 1 GHz, maximum. Velocity of propagation: 62 percent, nominal. Operating temperature range: -30 to +85C. Inner

9、 conductor properties: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-17/233B 3 DC resistance, maximum, at 20C: 0.65 ohms per 100 feet. Elongation: 15 percent, minimum. Tensile strength: 60 klbf/inch2, minimum. Engineering notes: This cable

10、useful in applications where electrical noise generated within the coaxial cable, due to flexure or vibration, must be limited. REQUIREMENTS: Dimensions, configuration and description: See figure 1 and table I. Environmental and mechanical: Visual and mechanical examination: Applicable. Adhesion of

11、conductors: Inner conductor to core: 7 pounds, minimum; 50 pounds maximum. Aging stability: +98 2C. Stress crack resistance: Not applicable. Outer conductor integrity: Not applicable. Cold bend: -40C 2C. Special requirements: Magnetic shield continuity: One hundred percent of all finished cable shal

12、l be tested for shield continuity prior to shipment. To establish continuity, no more than 25V dc shall be applied across the shield through an appropriate indicator, such as an ohmmeter, light or buzzer. Magnetic shield: To be applied to the maximum tension possible so as to prevent loosening or cr

13、eeping but not cause broken ends. Braids shall have no irregularities or loose unwoven strands. There shall be no splices of the completed braid. Dimensional stability: +85C 2C. Inner conductor from core: 0.062 inch, maximum. Inner conductor from jacket: .125 inch, maximum. Contamination: Not applic

14、able. Flame propagation: Applicable. Acid gas generation: 2.0 percent, maximum. Halogen content: 0.2 percent, maximum. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-17/233B 4 Immersion test: Tensile strength, percent of unaged minimum: 50.

15、Elongation, percent of unaged minimum: 50. Smoke index: 25 maximum. Toxicity index: 5 maximum. Durometer hardness (type A) 80 minimum. Weathering: Applicable. Abrasion resistance: 75 cycles minimum (jacket only). Tear strength: 35 pounds per inch. Heat distortion: 30 percent maximum. Physical tests

16、on unaged jacket: Tensile strength: 1,300 psi, minimum. Elongation: 160 percent, minimum. Physical tests on aged jacket: Air oven: Tensile strength, percent minimum: 60. Elongation: percent minimum: 60. Hot oil immersion: Tensile strength, percent minimum: 50. Elongation, percent minimum: 50. Tensil

17、e strength and elongation: 1,300 psi, 160 percent minimum. Weight: 0.235 Lbs/ft, maximum. Electrical: Spark test: 5,000 Vrms, +25 percent, -0 percent. Voltage withstanding: 10,000 Vrms, minimum. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL

18、-17/233B 5 Insulation resistance: 300,000 megohms, minimum per 1,000 feet (center conductor to outer conductor) at 1,000 V dc. 1,500,000 megohms, minimum per 200 feet (center conductor to outer conductor) at 1,000 V dc. 10 megohms, minimum per 1,000 feet (outer conductor to magnetic shield) at 500 V

19、 dc. 50 megohms, minimum per 200 feet (outer conductor to magnetic shield) at 500 V dc. 15 megohms, minimum per 1,000 feet (magnetic shield to outer jacket surface) at 500 V dc. 75 megohms, minimum per 200 feet (magnetic shield to outer jacket surface) at 500V dc. Corona extinction voltage: 5,000 V

20、rms, minimum. Characteristic impedance: 72 3 ohms. Attenuation: 15 dB per 100 feet, maximum at 400 MHz. Structural return loss: Not applicable. Capacitance: 23 +1 pF per foot, maximum. Capacitance unbalance: Not applicable. Transmission unbalance: Not applicable. Mechanically induced noise voltage:

21、320 microvolts peak to peak, maximum. Time delay: Not applicable. Shielding effectiveness: Frequency range: .00006 - .01 MHz. Surface transfer impedance, 8.184 milliohms/meter, maximum. Frequency range: .0101 100 MHz. Surface transfer impedance, 11.296 milliohms/meter, maximum. Surface transfer impe

22、dance measurements performed in accordance with SAE-AS85485. Testing performed with outer conductor shield and magnetic shield connected together on both ends and is considered the “Shield” in the test procedure. Part or Identifying Number (PIN): M17/233-00001 Change notations. The margins of this s

23、tandard are marked with vertical lines to indicate modifications generated by this change. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this docume

24、nt based on the entire content irrespective of the marginal notations. Referenced documents. In addition to MIL-DTL-17, this document references the following: MIL-N-14411 SAE-AS85485 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-17/233B 6

25、CONCLUDING MATERIAL Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force 85 (Project: 6145 - 2013 - 001) DLA - CC Review activities: Army - AR, AT, CR4, MI Navy - AS, MC, OS, SH Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1