1、MIL-DTL-17813/8 29 August 2009 DETAIL SPECIFICATION SHEET EXPANSION JOINTS, PIPE, METALLIC, HINGED This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification shee
2、t and MIL-DTL-17813. DN C-NPS inch (mm) Flange OD inch (mm) 1/ B (bolt circle diameter) inch (mm) 1/ 50 2 (50.8) 6 (152.4) 4.75 (120.7) 65 2.5 (76.2) 7 (177.8) 5.5 (139.7) 80 3 (76.2) 7.5 (190.5) 6 (152.4) 90 3.5 (101.6) 8.5 (215.9) 7 (177.8) 100 4 (101.6) 9 (228.6) 7.5 (190.5) 125 5 (127) 10 (254.0
3、) 8.5 (215.9) 150 6 (152.4) 11 (279.4) 9.5 (241.3) 200 8 (203.2) 13.5 (342.9) 11.75 (298.5) 250 10 (254) 16 (406.4) 14.25 (362.0) 300 12 (304.8) 19 ( 482.6) 17 (431.8) 350 14 (355.6) 21 (533.4) 18.75 (476.3) 400 16 (406.4) 23.5 (596.9) 21.25 (539.8) 450 18 (457.2) 25 (635) 22.75 (577.9) 500 20 (508)
4、 27.5 (698.5) 25 (635) 550 22 (558.8) - - 600 24 (609.6) 32 (812.8) 29.5 (749.3) 1/ See ASME B16.5, flange dimensions,150 pound. NOTES: 1. Dimensions are in inches. Metric equivalents are given for information only. 2. The illustration is for identification purposes only and is not intended to restr
5、ict designs and shapes of fastening devices, which conform to the requirements and are within the envelope dimensions. FIGURE 1. Expansion joint, hinged. AMSC N/A FSC 4730PIN BELLOWS C FLANGE OD B HINGE PLATE INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without lic
6、ense from IHS-,-,-MIL-DTL-17813/8 2 REQUIREMENTS: Design and construction: Dimensions and configuration: See figure 1. Construction: Hinged expansion joints shall be formed by one of the methods described in the EJMA Standards. Hinged expansion joints shall be constructed with two pins which run thr
7、ough plate assemblies on opposite sides of each other. The pin/plate construction shall provide a pivot point to permit angular rotation, in a single plane, of the pipe sections with respect to one another (see figure 1). The classification of the expansion joints covered under this specification sh
8、eet are as follows: Type I - shall have corrugated bellows. Class 6 - shall have a hinged construction. Materials and finishes. Materials and finishes for the bellows and flanges shall be in accordance with MIL-DTL-17813. The Part or Identifying Number (PIN) consists of the letters M, the basic spec
9、ification number, specification sheet number, size, type, class, pressure rating, and end connection. PIN example: M17813/8-3-I-6-150-W Referenced documents. In addition to MIL-DTL-17813, this document references the following: ASME B16.5 EJMA Standards Specification number Size Class M 17813 /8 - 3
10、 - I - 6 - 150 - W M prefix Specification sheet number End connection (F for flange ends, W for weld ends, and V for Vanstone ends) Type Pressure rating Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-17813/8 3 CONCLUDING MATERIAL Custodians:
11、 Preparing activity: Army - AT DLA - CC Navy - SH Air Force - 99 (Project 4730-2009-106) DLA - CC Review activities: Army - CE Navy MC, SA Air Force - 71 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-