DLA MIL-DTL-21097 4 G-2008 CONNECTORS ELECTRICAL PRINTED WIRING BOARD COMPOSITE RECEPTACLE CONTACT SPACING ( 200) ALTERNATE DUAL ROW TYPE CR《CR型交互式双列触点间距(200)印刷电路板复合插座式电气连接器》.pdf

上传人:unhappyhay135 文档编号:690083 上传时间:2018-12-30 格式:PDF 页数:6 大小:59.12KB
下载 相关 举报
DLA MIL-DTL-21097 4 G-2008 CONNECTORS ELECTRICAL PRINTED WIRING BOARD COMPOSITE RECEPTACLE CONTACT SPACING ( 200) ALTERNATE DUAL ROW TYPE CR《CR型交互式双列触点间距(200)印刷电路板复合插座式电气连接器》.pdf_第1页
第1页 / 共6页
DLA MIL-DTL-21097 4 G-2008 CONNECTORS ELECTRICAL PRINTED WIRING BOARD COMPOSITE RECEPTACLE CONTACT SPACING ( 200) ALTERNATE DUAL ROW TYPE CR《CR型交互式双列触点间距(200)印刷电路板复合插座式电气连接器》.pdf_第2页
第2页 / 共6页
DLA MIL-DTL-21097 4 G-2008 CONNECTORS ELECTRICAL PRINTED WIRING BOARD COMPOSITE RECEPTACLE CONTACT SPACING ( 200) ALTERNATE DUAL ROW TYPE CR《CR型交互式双列触点间距(200)印刷电路板复合插座式电气连接器》.pdf_第3页
第3页 / 共6页
DLA MIL-DTL-21097 4 G-2008 CONNECTORS ELECTRICAL PRINTED WIRING BOARD COMPOSITE RECEPTACLE CONTACT SPACING ( 200) ALTERNATE DUAL ROW TYPE CR《CR型交互式双列触点间距(200)印刷电路板复合插座式电气连接器》.pdf_第4页
第4页 / 共6页
DLA MIL-DTL-21097 4 G-2008 CONNECTORS ELECTRICAL PRINTED WIRING BOARD COMPOSITE RECEPTACLE CONTACT SPACING ( 200) ALTERNATE DUAL ROW TYPE CR《CR型交互式双列触点间距(200)印刷电路板复合插座式电气连接器》.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、AMSC N/A FSC 5935 MIL-DTL-21097/4G 23 June 2008 SUPERSEDING MIL- DTL-21097/4F 18 August 2005 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, PRINTED WIRING BOARD COMPOSITE, RECEPTACLE, CONTACT SPACING (.200) ALTERNATE DUAL ROW, TYPE CR This specification is approved for use by all Departments and

2、 Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-21097. FIGURE 1. Dual row contacts, type CR. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from

3、IHS-,-,-MIL-DTL-21097/4G 2NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only . 3. Unless otherwise specified, tolerance is .010 (.25 mm) for three place decimals. 4. Contacts and terminals shall be designated on the connector using numerals in the locations show

4、n. 5. The shape of the barriers is optional except that barriers shall not protrude beyond the plane of the underside of the mounting flange. 6. Slot shall accept the following thickness printed wiring boards: Size 2 - .054 (1.37 mm) to .071 (1.80 mm) Size 3 - .086 (2.18 mm) to .103 (2.62 mm) Slot s

5、hall prevent entry of printed wiring board having the following thickness: Size 2 - .084 (2.13 mm) Size 3 - .113 (2.87 mm) FIGURE 1. Dual row contacts, type CR Continued. Inches mm Inches mm .001 .03 .098 2.49 .002 .05 .100 2.54 .004 .10 .116 2.95 .005 .13 .125 3.18 .015 .38 .128 3.25 .020 .51 .140

6、3.56 .026 .66 .150 3.81 .030 .76 .200 5.08 .040 1.02 .210 5.33 .044 1.12 .325 8.26 .046 1.17 .326 8.28 .050 1.27 .328 8.33 .079 2.01 .350 8.89 Board guide A dim + .002 (.05) - .004 (.10) .06 (1.52) .09 (2.29) .119 (3.02) .150 (3.81) Provided by IHSNot for ResaleNo reproduction or networking permitte

7、d without license from IHS-,-,-MIL-DTL-21097/4G 3TABLE I. Connector, electrical, composite, receptacle, type CR, mounting provision A. Dimensions (inches) 1/ 2/ Dash number Style Class Size A (Maximum) B 0.015 (0.38) C 0.005 (0.13) D 0.010 (0.25) E 0.010 (0.25) 01 02 03 04 05 06 07 08 17 a a b b b b

8、 b b 2 3 2 2 2 3 3 3 2.570 (65.28) 2.300 (58.42) 1.600 (40.64) 0.531 (13.49) .123 (3.12) .154 (3.91) .186 (4.72) .123 (3.12) .154 (3.91) .186 (4.72) 09 10 11 12 13 14 15 16 23 a a b b b b b b 2 3 2 2 2 3 3 3 3.170 (80.52) 2.900 (73.66) 2.200 (55.88) 0.531 (13.49) .123 (3.12) .154 (3.91) .186 (4.72)

9、123 (3.12) .154 (3.91) .186 (4.72) See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-21097/4G 4TABLE I. Connector, electrical, composite, receptacle, type CR, mounting provision A Continued. Dimensions (inches) 1

10、/ 2/ Dash number Style Class Size A (Maximum) B 0.015 (0.38) C 0.005 (0.13) D 0.010 (0.25) E 0.010 (0.25) 17 18 19 20 21 22 23 24 29 a a b b b b b b 2 3 2 2 2 3 3 3 3.770 (95.76) 3.500 (88.90) 2.800 (71.12) 0.531 (13.49) .123 (3.12) .154 (3.91) .186 (4.72) .123 (3.12) .154 (3.91) .186 (4.72) 25 26 2

11、7 28 29 30 31 32 35 a a b b b b b b 2 3 2 2 2 3 3 3 4.370 (111.00) 4.100 (104.14) 3.400 (86.36) 0.531 (13.49) .123 (3.12) .154 (3.91) .186 (4.72) .123 (3.12) .154 (3.91) .186 (4.72) 33 34 35 36 37 38 39 40 41 a a b b b b b b 2 3 2 2 2 3 3 3 4.970 (126.24) 4.700 (119.38) 4.000 (101.6) 0.531 (13.49) .

12、123 (3.12) .154 (3.91) .186 (4.72) .123 (3.12) .154 (3.91) .186 (4.72) 1/ Dimensions are in inches. 2/ Metric equivalents are given for information only. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-21097/4G 5REQUIREMENTS Dimensions and co

13、nfiguration: See figure 1 and table I. Polarizing keys: Part or Identifying Number (PIN). M21097/11-03 or M21097/11-04. A key is inserted into the card slot at even contact numbers, 2, 4, 6, etc. Mating male adapters: Shall be in accordance with MIL-DTL-21097/5. Finish: Gold plating in accordance wi

14、th ASTM B488, type II, code C, class 1.27, over nickel plating in accordance with MIL-DTL-38999, Appendix A, class 2, 30 to 150 microinches. PIN: M21097/4-(dash number from table I). Qualfication: Not required. First article testing: First article testing shall be as specified in table II, tests sha

15、ll be in accordance with MIL-DTL-21097. Sample size: 8 connectors shall be subjected to the first article testing. All sample units shall be subjected to the inspections in group I. The sample units shall be divided equally into 2 groups of four and subjected to the inspection for their particular g

16、roups. TABLE II. First article tests. Inspection Group I (8 samples) Visual and mechanical inspection Permeability Insulation resistance Dielectric withstanding voltage Contact resistance Group II (4 samples) Temperature cycling Shock Bond strength, body assembly Contact retention Resistance to sold

17、ering heat Resistance to solvents Group III (4 samples) Salt spray (corrosion) Low-signal level contact resistance Contact resistance Bond strength, body assembly Failures: One or more failures shall be cause for refusal to grant first article approval. Provided by IHSNot for ResaleNo reproduction o

18、r networking permitted without license from IHS-,-,-MIL-DTL-21097/4G 6Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability

19、 whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-DTL-21097,

20、 this document references the following: MIL-DTL-21097/5 MIL-DTL-38999 ASTM B488 CONCLUDING MATERIALS Custodians: Preparing activity: Army CR DLA - CC Navy EC Air Force 85 (Project 5935-2008-085) DLA CC Review activities: Army AR, AT, AV, CR4, MI Navy AS, MC, OS, SH NOTE: The activities listed above

21、 were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN 25407 Bb 1-2012 Shielding walls against ionizing radiation - Supplement 1 Recommendations for the construction of walls made of bricks《防电离放射屏蔽墙 补充件1 铅制砖墙构筑的推荐规范》.pdf DIN 25407 Bb 1-2012 Shielding walls against ionizing radiation - Supplement 1 Recommendations for the construction of walls made of bricks《防电离放射屏蔽墙 补充件1 铅制砖墙构筑的推荐规范》.pdf
  • DIN 25407-1-2011 Shielding walls against ionizing radiation - Part 1 Bricks《防电离辐射的屏蔽墙 第1部分 砖块》.pdf DIN 25407-1-2011 Shielding walls against ionizing radiation - Part 1 Bricks《防电离辐射的屏蔽墙 第1部分 砖块》.pdf
  • DIN 25407-2-2011 Shielding walls against ionizing radiation - Part 2 Special construction elements for lead shielding walls《防电离辐射的屏蔽墙 第2部分 铅屏蔽墙用特殊构件》.pdf DIN 25407-2-2011 Shielding walls against ionizing radiation - Part 2 Special construction elements for lead shielding walls《防电离辐射的屏蔽墙 第2部分 铅屏蔽墙用特殊构件》.pdf
  • DIN 25407-3-2012 Shielding walls against ionizing radiation - Part 3 Construction of lead hot cells《防电离辐射的屏蔽墙 第3部分 铅热室结构》.pdf DIN 25407-3-2012 Shielding walls against ionizing radiation - Part 3 Construction of lead hot cells《防电离辐射的屏蔽墙 第3部分 铅热室结构》.pdf
  • DIN 25409 Bb 1-2015 Remote handling devices for use behind shielding walls Supplement 1 Recommendations for use《在护壁后面使用的遥控操作装置 补充1 使用推荐说明》.pdf DIN 25409 Bb 1-2015 Remote handling devices for use behind shielding walls Supplement 1 Recommendations for use《在护壁后面使用的遥控操作装置 补充1 使用推荐说明》.pdf
  • DIN 25409-1-2015 Remote handling devices for use behind shielding walls - Part 1 Remote handling tongs - Dimensions《屏蔽墙后面用遥控搬运装置 第1部分 遥控搬运抓手 尺寸》.pdf DIN 25409-1-2015 Remote handling devices for use behind shielding walls - Part 1 Remote handling tongs - Dimensions《屏蔽墙后面用遥控搬运装置 第1部分 遥控搬运抓手 尺寸》.pdf
  • DIN 25409-2-2015 Remote handling devices for use behind shielding walls - Part 2 Master-slave manipulators with three pivots - Dimensions《屏蔽墙后面用遥控搬运装置 第2部分 带三个枢轴仿效机械手 尺寸》.pdf DIN 25409-2-2015 Remote handling devices for use behind shielding walls - Part 2 Master-slave manipulators with three pivots - Dimensions《屏蔽墙后面用遥控搬运装置 第2部分 带三个枢轴仿效机械手 尺寸》.pdf
  • DIN 25409-3-2015 Remote handling devices for use behind shielding walls - Part 3 Telescopic master slave manipulators - Dimensions《屏蔽墙后面用遥控搬运装置 第3部分 伸缩式仿效机械手 尺寸》.pdf DIN 25409-3-2015 Remote handling devices for use behind shielding walls - Part 3 Telescopic master slave manipulators - Dimensions《屏蔽墙后面用遥控搬运装置 第3部分 伸缩式仿效机械手 尺寸》.pdf
  • DIN 25409-4-2015 Remote handling devices for use behind shielding walls - Part 4 Telescopic master slave manipulators - Requirements and tests《在屏蔽墙后面使用的遥控设备 第4部分 伸缩型主从控制器 要求和试验》.pdf DIN 25409-4-2015 Remote handling devices for use behind shielding walls - Part 4 Telescopic master slave manipulators - Requirements and tests《在屏蔽墙后面使用的遥控设备 第4部分 伸缩型主从控制器 要求和试验》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1