DLA MIL-DTL-24558 19 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 4-TERMINAL 8-WIRE 1000 VOLTS SYMBOL NO 444.pdf

上传人:sumcourage256 文档编号:690198 上传时间:2018-12-30 格式:PDF 页数:5 大小:144.75KB
下载 相关 举报
DLA MIL-DTL-24558 19 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 4-TERMINAL 8-WIRE 1000 VOLTS SYMBOL NO 444.pdf_第1页
第1页 / 共5页
DLA MIL-DTL-24558 19 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 4-TERMINAL 8-WIRE 1000 VOLTS SYMBOL NO 444.pdf_第2页
第2页 / 共5页
DLA MIL-DTL-24558 19 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 4-TERMINAL 8-WIRE 1000 VOLTS SYMBOL NO 444.pdf_第3页
第3页 / 共5页
DLA MIL-DTL-24558 19 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 4-TERMINAL 8-WIRE 1000 VOLTS SYMBOL NO 444.pdf_第4页
第4页 / 共5页
DLA MIL-DTL-24558 19 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 4-TERMINAL 8-WIRE 1000 VOLTS SYMBOL NO 444.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5940 INCH-POUND MIL-DTL-24558/19B 3 October 2011 SUPERSEDING MIL-DTL-24558/19A 9 December 2004 DETAIL SPECIFICATION SHEET TERMINAL BOX, CONNECTION, SUBMERSIBLE (15-FOOT), 4-TERMINAL, 8-WIRE, 1000 VOLTS, SYMBOL NO. 444 This specification is approved for use by all Departments and Agencie

2、s of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24558, “Terminal Boxes, Connection, for Electrical and Electronic Systems, General Specification for“. REQUIREMENTS: The terminal box shall be as specifie

3、d herein and in accordance with table I and figures 1 through 3. 1. Electrical rating. The terminal box shall have an electrical rating of 1000 volts root mean square, and 1000 volts direct current. The maximum current shall not exceed 40 amperes per stud of terminal board. 2. Dimensions and configu

4、ration. For dimensions and configuration see figures 1 through 3. All dimensions in figures 1 through 3 are expressed in decimal inches. Overall terminal box dimensions are approximate. Exact dimensions are shown in MIL-E-24142/5, “Enclosure for Electrical Fittings and Fixtures, Submersible, (15-Foo

5、t), Sizes 3R, 4R and 5R“. 3. Tolerance. All tolerances not specified herein shall be in accordance with MIL-DTL-24558. 4. Standard parts. The standard parts shown in table I shall be used in the construction of the connection box specified herein. The numbers in circles shown on figures 1 and 2 are

6、the same as those shown in the “Item“ column of table I. 5. Enclosure. The enclosure shall be a 15-foot submersible type. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/19B 2 6. Finish. The interior of the enclosure may be painted or l

7、eft unpainted at the contractors option. 7. Weight. The weight of the connection box shall not exceed 3.25 pounds. 8. Maximum number of wires. The maximum number of wires (including spares) shall not exceed two times the number of terminals. The maximum number of wires to be connected to a single te

8、rminal shall not exceed four. QUALITY ASSURANCE: First article inspection and quality conformance inspection shall be as specified in MIL-DTL-24558. NOTES: 1. Drawing. The terminal box specified by this specification sheet was formerly covered on NAVSHIPS drawing no. 815-1197014. 2. Part or identify

9、ing number (PIN). The PIN to be used for terminal boxes acquired to this specification is created as follows: M 24558/19 - 444 Symbol number Specification sheet number General specification number Denotes military specification TABLE I. Parts list. Item Description Qty Part number or specification R

10、emarks 1 Enclosure assembly, brass 1 MIL-E-24142/5 M24142/5-003 2 Identification plate 1 MIL-DTL-24558 Figure 6 3 Information plate 1 MIL-DTL-24558 Figure 6 4 Mounting bracket 2 MIL-DTL-24558 Figure 3 5 Terminal board assembly 1 A-A-59125/20 16TB4 6 RDH machine screw 10-24 X 0.750 2 Commercial Brass

11、 7 Washer, #10 external tooth 2 Commercial Bronze 8 Warning plate 1 MIL-DTL-15024 Brass 11A 3.500-inch by 1.375 inch-plate shall be brazed to the cover of the connection box as shown in figure 1. “WARNING“ (first line), and “1000 VOLTS“ (second line), shall be engraved in 0.375-inch lettering. Lette

12、ring shall be filled with red enamel in accordance with FED-STD-595/21105. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/19B 3 FIGURE 1. Connection box assembly. Provided by IHSNot for ResaleNo reproduction or networking permitted wit

13、hout license from IHS-,-,-MIL-DTL-24558/19B 4 FIGURE 2. Location of terminal board mounting brackets. FIGURE 3. Mounting dimensions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/19B 5 CHANGES FROM PREVIOUS ISSUE. Marginal notations a

14、re not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Navy - SH DLA - GS DLA - GS4 (Project 5940-2011-046) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS EN 50131-5-3-2017 Alarm systems Intrusion systems Requirements for interconnections equipment using radio frequency techniques《警报系统 侵入探测系统 使用射频技术的互联设备要求》.pdf BS EN 50131-5-3-2017 Alarm systems Intrusion systems Requirements for interconnections equipment using radio frequency techniques《警报系统 侵入探测系统 使用射频技术的互联设备要求》.pdf
  • BS EN 50131-6-2008 Alarm systems - Intrusion and hold-up systems - Power supplies《报警系统 侵入和拦截系统 电源》.pdf BS EN 50131-6-2008 Alarm systems - Intrusion and hold-up systems - Power supplies《报警系统 侵入和拦截系统 电源》.pdf
  • BS EN 50131-8-2009 Alarm systems - Intrusion and hold-up systems - Part 8 Security fog device systems《报警系统 侵入和拦截系统 第8部分 安全烟雾设备 系统》.pdf BS EN 50131-8-2009 Alarm systems - Intrusion and hold-up systems - Part 8 Security fog device systems《报警系统 侵入和拦截系统 第8部分 安全烟雾设备 系统》.pdf
  • BS EN 50132-1-2010 Alarm systems CCTV nsurveillance systems for nuse in security applications  nPart 1 System requirements《警报系统 安全设备用CCTV监测系统 第1部分 系统要求》.pdf BS EN 50132-1-2010 Alarm systems CCTV nsurveillance systems for nuse in security applications nPart 1 System requirements《警报系统 安全设备用CCTV监测系统 第1部分 系统要求》.pdf
  • BS EN 50132-5-1-2011 Alarm systems CCTV surveillance systems for use in security applications Video transmission General video transmission performance requirements《报警系统 闭路电视(CCTV).pdf BS EN 50132-5-1-2011 Alarm systems CCTV surveillance systems for use in security applications Video transmission General video transmission performance requirements《报警系统 闭路电视(CCTV).pdf
  • BS EN 50132-5-2-2011 Alarm systems CCTV surveillance systems for use in security applications IP Video Transmission Protocols《报警系统 闭路电视(CCTV)安全性监控系统 互联网视频传输协议》.pdf BS EN 50132-5-2-2011 Alarm systems CCTV surveillance systems for use in security applications IP Video Transmission Protocols《报警系统 闭路电视(CCTV)安全性监控系统 互联网视频传输协议》.pdf
  • BS EN 50132-5-3-2012 Alarm systems CCTV surveillance systems for use in security applications Video transmission Analogue and digital video transmission《报警系统 安全设备用闭路电视监控系统 视频传输 模拟和.pdf BS EN 50132-5-3-2012 Alarm systems CCTV surveillance systems for use in security applications Video transmission Analogue and digital video transmission《报警系统 安全设备用闭路电视监控系统 视频传输 模拟和.pdf
  • BS EN 50132-7-2012 Alarm systems CCTV surveillance systems for use in security applications Application guidelines《警报系统 用于安保应用方面的闭路电视监控系统 应用指南》.pdf BS EN 50132-7-2012 Alarm systems CCTV surveillance systems for use in security applications Application guidelines《警报系统 用于安保应用方面的闭路电视监控系统 应用指南》.pdf
  • BS EN 50133-2-1-2000 Alarm systems - Access control systems for use in security applications - General requirements for components《报警系统 安全用通路控制系统 元件一般要求》.pdf BS EN 50133-2-1-2000 Alarm systems - Access control systems for use in security applications - General requirements for components《报警系统 安全用通路控制系统 元件一般要求》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1