DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf

上传人:wealthynice100 文档编号:690204 上传时间:2018-12-30 格式:PDF 页数:10 大小:254.98KB
下载 相关 举报
DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf_第1页
第1页 / 共10页
DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf_第2页
第2页 / 共10页
DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf_第3页
第3页 / 共10页
DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf_第4页
第4页 / 共10页
DLA MIL-DTL-24558 24 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 500 VOLTS THREE-PHASE SYMBOL NO 416 TWO-CIRCUIT THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES.pdf_第5页
第5页 / 共10页
点击查看更多>>
资源描述

1、AMSC N/A FSC 5940 INCH-POUND MIL-DTL-24558/24B 3 October 2011 SUPERSEDING MIL-DTL-24558/24A w/AMENDMENT 1 17 February 2006 DETAIL SPECIFICATION SHEET TERMINAL BOX, CONNECTION, SUBMERSIBLE (15-FOOT), 500 VOLTS, THREE-PHASE, SYMBOL NO. 416, TWO-CIRCUIT, THREE-PHASE BUS LUGS FOR TWO 75 MCM CABLES This

2、specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24558, “Terminal Boxes, Connection, for Electrical and Electronic Systems, General Specifi

3、cation for“. REQUIREMENTS: The terminal box shall be as specified herein and in accordance table I and figures 1 through 6. 1. Electrical rating. The terminal box shall have an electrical rating of 500 volts root mean square, and 500 volts direct current. The maximum current shall not exceed 200 amp

4、eres per terminal lug. 2. Dimensions and configuration. For dimensions and configuration see figures 1 through 6. All dimensions in figures 1 through 6 are expressed in decimal inches. Overall terminal box dimensions are approximate. Exact dimensions are shown in MIL-E-24142/3, “Enclosure for Electr

5、ical Fittings and Fixtures, Submersible, Size 6 by 9 (15-Foot)“. 3. Tolerance. All tolerances other than specified herein, shall be in accordance with MIL-DTL-24558. 4. Standard parts. The standard parts shown in table I shall be used in the construction of the connection box specified herein. The n

6、umbers in circles shown on figures 1, 2, 4, 5, and 6 are the same as those shown in the “Item“ column of table I. Provided by IHSNot for Resale-,-,-MIL-DTL-24558/24B 2 5. Enclosure. The enclosure shall be a 15-foot submersible type. 6. Finish. The interior of the enclosure may be painted or left unp

7、ainted at the contractors option. 7. Weight. The weight of the connection box shall not exceed 10.0 pounds. QUALITY ASSURANCE: First article inspection and quality conformance inspection shall be as specified in MIL-DTL-24558. NOTES: 1. Drawing. The terminal box specified by this specification sheet

8、 was formerly covered on NAVSHIPS drawing no. 9000-S6202-74192. 2. Part or identifying number (PIN). The PIN to be used for terminal boxes acquired to this specification is created as follows: M 24558/24 - 416 Symbol number Specification sheet number General specification number Denotes military spe

9、cification Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHSMIL-DTL-24558/24B 3 TABLE I. Parts list. Item Description Qty Part number or specification Remarks 1 Enclosure assembly, brass 1 MIL-E-24142/3 M24142/3-001 2 Identification plate 1 MIL-DTL-24558 F

10、igure 6 3 Information plate 1 MIL-DTL-24558 Figure 6 4 Mounting pads 4 Figure 2 5 Terminal board base 1 Figure 4 MIL-I-24768/1 type GME 6 Terminal board sub-base 1 Figure 5 MIL-I-24768/1 type GME 7 Terminal body 6 9000-S6202-73246, pc 3 Brass 8 Terminal pressure screw assembly 6 9000-S6202-73246, pc

11、 23 Brass 9 Terminal lug assembly, straight 1 Figure 6 10 Terminal lug assembly, 30-degree 2 Figure 6 11 RDH machine screw 1/4-20 X 0.625 4 Commercial Brass 12 Washer, 1/4 internal tooth 4 Commercial Bronze 13 RDH machine screw 6-32 X 0.188 4 Commercial Brass 14 RDH machine screw 10-24 X 0.500 6 Com

12、mercial Brass 15 Washer, #10 internal tooth 6 Commercial Bronze Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHSMIL-DTL-24558/24B 4 FIGURE 1. Connection box assembly. Provided by IHSNot for Resale-,-,-MIL-DTL-24558/24B 5 FIGURE 2. Location of terminal boa

13、rd mounting pads. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHSMIL-DTL-24558/24B 6 FIGURE 3. Mounting dimensions. Provided by IHSNot for Resale-,-,-MIL-DTL-24558/24B 7 FIGURE 4. Terminal board base. Provided by IHSNot for Resale-,-,-MIL-DTL-24558/24B 8

14、 FIGURE 5. Terminal board sub-base. Provided by IHSNot for Resale-,-,-MIL-DTL-24558/24B 9 FIGURE 6. Terminal lug assemblies. Provided by IHSNot for Resale-,-,-MIL-DTL-24558/24B 10 CHANGES FROM PREVIOUS ISSUE. Marginal notations are not used in this revision to identify changes with respect to the pr

15、evious issue due to the extent of the changes. Custodians: Preparing Activity: Navy - SH DLA - GS DLA - GS4 (Project 5940-2011-051) NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for Resale-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN VDE 0855-300-2008 Transmitting receiving systems for transmitter RF output power up to 1 kW - Part 300 Safety requirements《发射机射频(RF)输出功率小于1kW的发射 接收设备 第300部分 安全要求》.pdf DIN VDE 0855-300-2008 Transmitting receiving systems for transmitter RF output power up to 1 kW - Part 300 Safety requirements《发射机射频(RF)输出功率小于1kW的发射 接收设备 第300部分 安全要求》.pdf
  • DIN VDE 0881-1986 Equipment wires and flexible equipment wires with extended temperature range for telecommunication systems and data processing systems [VDE Specification]《通信系统和数据.pdf DIN VDE 0881-1986 Equipment wires and flexible equipment wires with extended temperature range for telecommunication systems and data processing systems [VDE Specification]《通信系统和数据.pdf
  • DIN VDE 0888-745-2010 Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Type EM-RJ connector family Text in German and English《光纤互连设备和.pdf DIN VDE 0888-745-2010 Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Type EM-RJ connector family Text in German and English《光纤互连设备和.pdf
  • DIN VDE 0891-1-1990 Use of cables and insulated wires for telecommunication systems and information processing systems general directions《电缆和绝缘导线在电信设备和信息处理设备上的应用 通用用法》.pdf DIN VDE 0891-1-1990 Use of cables and insulated wires for telecommunication systems and information processing systems general directions《电缆和绝缘导线在电信设备和信息处理设备上的应用 通用用法》.pdf
  • DIN VDE 0891-2-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for equipment wires with solid or stranded.pdf DIN VDE 0891-2-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for equipment wires with solid or stranded.pdf
  • DIN VDE 0891-3-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for switchbord cables according to DIN VDE.pdf DIN VDE 0891-3-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for switchbord cables according to DIN VDE.pdf
  • DIN VDE 0891-5-1985 Use of cables and insulated wires for telecommunication systems and data processing systems special direction for wiring cables according to DIN VDE 0815《通信系统和信.pdf DIN VDE 0891-5-1985 Use of cables and insulated wires for telecommunication systems and data processing systems special direction for wiring cables according to DIN VDE 0815《通信系统和信.pdf
  • DIN VDE 0891-6-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for external cables according to DIN VDE 0.pdf DIN VDE 0891-6-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for external cables according to DIN VDE 0.pdf
  • DIN VDE 0891-9-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for equipment wires and stranded connectin.pdf DIN VDE 0891-9-1990 Use of cables and insulated wires for telecommunication systems and information processing systems special directions for equipment wires and stranded connectin.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1