DLA MIL-DTL-24558 6 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 40-TERMINAL 160-WIRE 600 VOLTS SYMBOL NO 433 1.pdf

上传人:李朗 文档编号:690214 上传时间:2018-12-30 格式:PDF 页数:6 大小:162.86KB
下载 相关 举报
DLA MIL-DTL-24558 6 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 40-TERMINAL 160-WIRE 600 VOLTS SYMBOL NO 433 1.pdf_第1页
第1页 / 共6页
DLA MIL-DTL-24558 6 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 40-TERMINAL 160-WIRE 600 VOLTS SYMBOL NO 433 1.pdf_第2页
第2页 / 共6页
DLA MIL-DTL-24558 6 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 40-TERMINAL 160-WIRE 600 VOLTS SYMBOL NO 433 1.pdf_第3页
第3页 / 共6页
DLA MIL-DTL-24558 6 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 40-TERMINAL 160-WIRE 600 VOLTS SYMBOL NO 433 1.pdf_第4页
第4页 / 共6页
DLA MIL-DTL-24558 6 B-2011 TERMINAL BOX CONNECTION SUBMERSIBLE (15-FOOT) 40-TERMINAL 160-WIRE 600 VOLTS SYMBOL NO 433 1.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、AMSC N/A FSC 5940 INCH-POUND MIL-DTL-24558/6B 3 October 2011 SUPERSEDING MIL-DTL-24558/6A w/AMENDMENT 1 17 February 2006 DETAIL SPECIFICATION SHEET TERMINAL BOX, CONNECTION, SUBMERSIBLE (15-FOOT), 40-TERMINAL, 160-WIRE, 600 VOLTS, SYMBOL NO. 433.1 This specification is approved for use by all Depart

2、ments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-24558, “Terminal Boxes, Connection, for Electrical and Electronic Systems, General Specification for“. REQUIREMENTS: The terminal box sha

3、ll be as specified herein and in accordance with table I and figures 1 through 3. 1. Electrical rating. The terminal box shall have an electrical rating of 600 volts root mean square, and 600 volts direct current. The maximum current shall not exceed 40 amperes per stud of terminal board. 2. Dimensi

4、ons and configuration. For dimensions and configuration see figures 1 through 3. All dimensions in figures 1 through 3 are expressed in decimal inches. Overall terminal box dimensions are approximate. Exact dimensions are shown in MIL-E-24142/6, “Enclosure, Submersible (15-Foot), Sizes 8 by 10 Throu

5、gh 14 by 26“. 3. Tolerance. All tolerances not specified herein shall be in accordance with MIL-DTL-24558. 4. Standard parts. The standard parts shown in table I shall be used in the construction of the connection box specified herein. The numbers in circles shown on figures 1 and 2 are the same as

6、those shown in the “Item“ column of table I. 5. Enclosure. The enclosure shall be a 15-foot submersible type. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/6B 2 6. Weight. The weight of the connection box shall not exceed 18.0 pounds.

7、 7. Maximum number of wires. The maximum number of wires (including spares) shall not exceed four times the number of terminals. The maximum number of wires to be connected to a single terminal shall not exceed four. QUALITY ASSURANCE: First article inspection and quality conformance inspection shal

8、l be as specified in MIL-DTL-24558. NOTES: 1. Drawing. The terminal box specified by this specification sheet was formerly covered on NAVSHIPS drawing no. 9000-S6202-74133. 2. Part or identifying number (PIN). The PIN to be used for terminal boxes acquired to this specification is created as follows

9、: M 24558/6 - 433.1 Symbol number Specification sheet number General specification number Denotes military specification TABLE I. Parts list. Item Description Qty Part number or specification Remarks 1 Enclosure assembly, brass with type A cover 1 MIL-E-24142/6 M24142/6-001 2 Identification plate 1

10、MIL-DTL-24558 Figure 6 3 Information plate 1 MIL-DTL-24558 Figure 6 4 Mounting bracket 2 MIL-DTL-24558 Figure 1 5 Terminal board assembly 2 A-A-59125/10 4TB20 6 RDH machine screw 10-24 X 0.875 4 Commercial Brass 7 Washer, #10 external tooth 4 Commercial Bronze 8 RDH machine screw 6-32 X 0.250 4 Comm

11、ercial Brass Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/6B 3 FIGURE 1. Connection box assembly. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/6B 4 FIGURE 2. Location

12、 of terminal board mounting brackets. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/6B 5 FIGURE 3. Mounting dimensions. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-24558/6B

13、 6 CHANGES FROM PREVIOUS ISSUE. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Navy - SH DLA - GS DLA - GS4 (Project 5940-2011-033) NOTE: The activities listed above were intere

14、sted in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-