1、AMSC N/A FSC 5985 MIL-DTL-28837/7B 5 July 2012 SUPERSEDING MIL-DTL-28837/7A 30 October 2001 DETAIL SPECIFICATION SHEET MIXER STAGES, RADIO FREQUENCY, DOUBLE BALANCED, TO-5 CONFIGURATION This specification is approved for use by all Departments and Agencies of the Department of Defense. The requireme

2、nts for acquiring the product described herein shall consist of this specification and MIL-DTL-28837. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only and are based upon 1.00 inch = 25.4 mm. FIGURE 1. Outline drawing for mixers PIN M28837/7-01N, M28837

3、/7-02N, and M28837/7-02S. INCH-POUND Dimension Ltr Inches mm Min Max Min Max A .315 .345 8.00 8.76 B - .407 - 10.34 C .140 - 3.56 - D .015 DIA .019 DIA 0.38 DIA 0.48 DIA E .335 .370 8.51 9.40 F .190 .210 4.83 5.33 G - .050 - 1.27 H .026 .036 0.66 0.91 Provided by IHSNot for ResaleNo reproduction or

4、networking permitted without license from IHS-,-,-MIL-DTL-28837/7B 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only and are based upon 1 inch = 25.4 mm. FIGURE 2. Outline drawing for mixers PIN M28837/7-03N. Dimension Ltr Inches mm Min Max Min Max A

5、305 .335 7.75 8.51 B - .275 - 6.99 C .140 - 3.56 - D .015 DIA .019 DIA 0.38 DIA 0.48 DIA E .335 .370 8.51 9.40 F .190 .210 4.83 5.33 G - .050 - 1.27 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-28837/7B 3 REQUIREMENTS: Design and construc

6、tion: Dimensions and configuration: See figures 1 and 2. Electrical characteristics: Operating frequency range: See table I. LO drive power: See table I. Conversion loss (max): See table I. Noise figure (SSB): See table I. Isolation (minimum): See table I. Maximum input power: See table I. Conversio

7、n compression: See table I. Desensitization: See table I. Physical and environmental characteristics: Weight: 2 grams maximum. Temperature: -01N, 03N = Operating: -54C to +100C. Nonoperating: -65C to +100C -02N, 02S = Operating: -65C to +100C. Nonoperating: -65C to +100C Shock: Test condition C. Lif

8、e: -01 = 100,000 hours minimum. Seal: Hermetic. Part or Identifying Number (PIN) Space flight mixers shall be marked with “T”, example M28837/7- 01 T Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AMSC N/A FSC 5985 TABLE I. Electrical characteristic

9、s. Dash no. Operating frequency range (MHz) LO input drive power in dBm 1/ Maximum conversion loss (SSB) dB MHz Noise figure (SSB) dB MHz Isolation Minimum Frequency LO-RF LO-IF RF-IF dB dB dB MHz 01N 01S RF 10-500 LO 10-5000 IF DC-500 nominal +7 TV +7 7.0 at: fLand fR 10-200 fIDC-200 7.0 at: fLand

10、fR 10-200 fI0.4-200 40 35 30 25 35 30 25 15 25 20 15 10 10-50 50-100 100-200 200-500 8.0 at: fLand fR 200-350 fIDC-350 8.0 at: fLand fR 200-350 fI0.4-350 9.0 at: fLand fR 350-500 fIDC-500 9.0 at: fLand fR 350-500 fI0.4-500 02N 2/ 02S RF 350-500 LO 350-500 IF DC-500 nominal +7 TV +7 9.0 at: fLand fR

11、350-500 fIDC-500 9.0 at: fLand fR 350-500 fI0.4-500 25 15 10 350-500 03N 03S RF 0.4-500 LO 0.4-500 IF DC-500 minimum +4 TV +7 maximum +13 6.5 at: fLand fR 1-200 fIDC-200 6.5 at: fLand fR 2-200 fI2-200 45 30 N/A 0.4-60 7.5 at: fLand fR 0.4-500 fIDC-500 7.5 at: fLand fR 2-500 fI2-500 30 20 N/A 60-500

12、1/ Unless otherwise specified, TV is the test value of the LO power for electrical characteristics. 2/ Use for reacquisition purposes only. 3/ With two in-phase signals applied to the LO and RF ports. MIL-DTL-28837/7B4Provided by IHSNot for ResaleNo reproduction or networking permitted without licen

13、se from IHS-,-,-MIL-DTL-28837/7B 5 Referenced documents. This specification sheet only references MIL-DTL-28837. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing activity: Army - CR DLA - C

14、C Navy - EC Air Force - 85 (Project 5895-2012-004) DLA - CC Review activities: Army - AR, MI Navy - AS, CG, MC, OS Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS EN 60704-2-8-1997 Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Particular requirements for electric shavers《家用和类似.pdf BS EN 60704-2-8-1997 Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Particular requirements for electric shavers《家用和类似.pdf
  • BS EN 60704-2-9-2003 Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Particular requirements for electric hair care app.pdf BS EN 60704-2-9-2003 Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Particular requirements for electric hair care app.pdf
  • BS EN 60704-3-2006 Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Procedure for determining and verifying declared noi.pdf BS EN 60704-3-2006 Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Procedure for determining and verifying declared noi.pdf
  • BS EN 60705-2015 Household microwave ovens Methods for measuring performance《家用微波炉 性能测试方法》.pdf BS EN 60705-2015 Household microwave ovens Methods for measuring performance《家用微波炉 性能测试方法》.pdf
  • BS EN 60706-2-2006 Maintainability of equipment - Maintainability requirements and studies during the design and development phase《设备的维修性 设计和开发阶段期间的维修性要求和研究》.pdf BS EN 60706-2-2006 Maintainability of equipment - Maintainability requirements and studies during the design and development phase《设备的维修性 设计和开发阶段期间的维修性要求和研究》.pdf
  • BS EN 60706-3-2006 Maintainability of equipment - Verification and collection analysis and presentation of data《设备的维修性 数据验证、收集、分析和表示》.pdf BS EN 60706-3-2006 Maintainability of equipment - Verification and collection analysis and presentation of data《设备的维修性 数据验证、收集、分析和表示》.pdf
  • BS EN 60706-5-2007 Maintainability of equipment Part 5 Testability and diagnostic ntesting《设备的可维护性 第5部分 故障易测性和诊断测试》.pdf BS EN 60706-5-2007 Maintainability of equipment Part 5 Testability and diagnostic ntesting《设备的可维护性 第5部分 故障易测性和诊断测试》.pdf
  • BS EN 60708-2005 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath《带聚烯烃绝缘和隔潮层聚烯烃护套的低频电缆》.pdf BS EN 60708-2005 Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath《带聚烯烃绝缘和隔潮层聚烯烃护套的低频电缆》.pdf
  • BS EN 60709-2010 Nuclear power plants - Instrumentation and control systems important to safety - Separation《核电站 重要安全性仪器仪表和控制系统 隔离》.pdf BS EN 60709-2010 Nuclear power plants - Instrumentation and control systems important to safety - Separation《核电站 重要安全性仪器仪表和控制系统 隔离》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1