DLA MIL-DTL-28840 16 D-2013 CONNECTORS ELECTRICAL CIRCULAR THREADED HIGH SHOCK HIGH DENSITY SHIPBOARD CRIMP CONTACTS PLUG CLASSES D DS P T TS Z AND ZS.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5935 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, THREADED, HIGH SHOCK, HIGH DENSITY, SHIPBOARD, CRIMP CONTACTS, PLUG, CLASSES D, DS, P, T, TS, Z, AND ZS This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements

2、 for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-28840. Inches mm 1.938 49.23 FIGURE 1. Dimensions and configuration. MIL-DTL-28840/16D 14 November 2013 SUPERSEDING MIL-DTL-28840/16C 23 October 2009 INCH-POUND Provided by IHSNot for ResaleNo reproduct

3、ion or networking permitted without license from IHS-,-,-MIL-DTL-28840/16D 2 Shell size designator (See note 3) Q dia max A (11) 1.028 (26.11) B (13) 1.141 (28.98) C (15) 1.263 (32.08) D (17) 1.387 (35.23) E (19) 1.513 (38.43) F (23) 1.703 (43.26) G (25) 1.825 (46.36) H (29) 2.143 (54.43) J (33) 2.3

4、29 (59.16) NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. Shell sizes are provided within parentheses for information and are not a part of the designator. 4. Dimensions apply after plating. 5. Normal mating key position shown. Alternate key positions sh

5、all be in accordance with MIL-DTL-28840. FIGURE 1. Dimensions and configuration Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-28840/16D 3 REQUIREMENTS: Dimensions and configuration: See figure 1. Classes: D, DS, P, T, TS, Z and Z

6、S. Insert arrangements: See the figure of MIL-STD-1698 corresponding to the desired shell size. Contacts: Pin or socket, crimp type, styles P, S, D, E, F or G, in accordance with MIL-DTL-28840. Shell polarization: 1 thru 6, key position. Marking: Part or Identifying Number (PIN) on shell. Mating cou

7、nterpart: Receptacle connectors in accordance with MIL-DTL-28840/10, /11, /12, /14, /20, and /21. Installation and removal tools: In accordance with MIL-I-81969/33 and /34. A backshell shall be used to meet the moisture and water pressure requirements. PIN example: M28840/ 16 A G 1 P 1 Military desi

8、gnator Specification sheet number Class code letter (Class D, code letter A) (Class DS, code letter B) (Class P, code letter F (Class T, code letter L) (Class TS, code letter N) (Class Z, code letter S) (Class ZS, code letter R) Shell size (See figure 1) Insert arrangement (See figure 1 and MIL-STD-

9、1698) Contact style (See MIL-DTL-28840) Keying (See MIL-DTL-28840) RESTRICTIONS: Classes D and DS are inactive for NAVSEA new design, unless approved by NAVSEA. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-28840/16D 4 Changes from previous

10、 issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned

11、to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-DTL-28840, this document references the following: MIL-DTL-28840/10 MIL-DTL-28840/11 MIL-DTL-28840/12

12、 MIL-DTL-28840/14 MIL-DTL-28840/20 MIL-DTL-28840/21 MIL-I-81969/33 MIL-I-81969/34 MIL-STD-1698 CONCLUDING MATERIAL Custodians: Preparing activity: Army - AT DLA - CC Navy - EC Air Force - 85 DLA - CC (Project 5935-2013-114) Review activities: Army AV, MI Air Force 99 NOTE: The activities listed abov

13、e were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM D5422-2009 866 Standard Test Method for Measurement of Properties of Thermoplastic Materials by Screw-Extrusion Capillary Rheometer《用螺旋挤出式毛细管流变仪测量热塑性材料性能的标准试验方法》.pdf ASTM D5422-2009 866 Standard Test Method for Measurement of Properties of Thermoplastic Materials by Screw-Extrusion Capillary Rheometer《用螺旋挤出式毛细管流变仪测量热塑性材料性能的标准试验方法》.pdf
  • ASTM D5422-2017 red 7500 Standard Test Method for Measurement of Properties of Thermoplastic Materials by Screw-Extrusion Capillary Rheometer《用螺杆挤出毛细管流变仪测量热塑性材料性能的标准试验方法》.pdf ASTM D5422-2017 red 7500 Standard Test Method for Measurement of Properties of Thermoplastic Materials by Screw-Extrusion Capillary Rheometer《用螺杆挤出毛细管流变仪测量热塑性材料性能的标准试验方法》.pdf
  • ASTM D5423-2014 6552 Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation《电气绝缘评估用实验室强制对流炉的标准规范》.pdf ASTM D5423-2014 6552 Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation《电气绝缘评估用实验室强制对流炉的标准规范》.pdf
  • ASTM D5424-2005 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configurati.pdf ASTM D5424-2005 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configurati.pdf
  • ASTM D5424-2010 2500 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Config.pdf ASTM D5424-2010 2500 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Config.pdf
  • ASTM D5424-2014 red 8023 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Co.pdf ASTM D5424-2014 red 8023 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Co.pdf
  • ASTM D5425-2002 Standard Guide for Development of Fire Hazard Assessment Standards of Electrotechnical Products《制定电工技术产品着火危险评定标准用的标准指南》.pdf ASTM D5425-2002 Standard Guide for Development of Fire Hazard Assessment Standards of Electrotechnical Products《制定电工技术产品着火危险评定标准用的标准指南》.pdf
  • ASTM D5425-2008 923 Standard Guide for Development of Fire Hazard Assessment Standards of Electrotechnical Products《电工产品火灾危险评估标准的制定的标准指南》.pdf ASTM D5425-2008 923 Standard Guide for Development of Fire Hazard Assessment Standards of Electrotechnical Products《电工产品火灾危险评估标准的制定的标准指南》.pdf
  • ASTM D5425-2013 5890 Standard Guide for Development of Fire Hazard Assessment Standards of Electrotechnical Products《制定电工技术产品着火危险评定标准用的标准指南》.pdf ASTM D5425-2013 5890 Standard Guide for Development of Fire Hazard Assessment Standards of Electrotechnical Products《制定电工技术产品着火危险评定标准用的标准指南》.pdf