DLA MIL-DTL-32385 1-2011 CONNECTOR RECEPTACLE CENTER CONTACT POSITIVE PANEL GROUND TYPE [Superseded NAVY MS90335 REV D NAVY MS90335 REV C NAVY MS90335 REV B NAVY MS90335 REV A DLA .pdf

上传人:ideacase155 文档编号:690573 上传时间:2018-12-30 格式:PDF 页数:4 大小:115.03KB
下载 相关 举报
DLA MIL-DTL-32385 1-2011 CONNECTOR RECEPTACLE CENTER CONTACT POSITIVE PANEL GROUND TYPE [Superseded NAVY MS90335 REV D NAVY MS90335 REV C NAVY MS90335 REV B NAVY MS90335 REV A DLA .pdf_第1页
第1页 / 共4页
DLA MIL-DTL-32385 1-2011 CONNECTOR RECEPTACLE CENTER CONTACT POSITIVE PANEL GROUND TYPE [Superseded NAVY MS90335 REV D NAVY MS90335 REV C NAVY MS90335 REV B NAVY MS90335 REV A DLA .pdf_第2页
第2页 / 共4页
DLA MIL-DTL-32385 1-2011 CONNECTOR RECEPTACLE CENTER CONTACT POSITIVE PANEL GROUND TYPE [Superseded NAVY MS90335 REV D NAVY MS90335 REV C NAVY MS90335 REV B NAVY MS90335 REV A DLA .pdf_第3页
第3页 / 共4页
DLA MIL-DTL-32385 1-2011 CONNECTOR RECEPTACLE CENTER CONTACT POSITIVE PANEL GROUND TYPE [Superseded NAVY MS90335 REV D NAVY MS90335 REV C NAVY MS90335 REV B NAVY MS90335 REV A DLA .pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5935 INCH-POUND MIL-DTL-32385/1 14 July 2011 SUPERSEDING MS90335D 5 January 1996 DETAIL SPECIFICATION SHEET CONNECTOR, RECEPTACLE, CENTER CONTACT POSITIVE, PANEL GROUND TYPE This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirem

2、ents for acquiring the product described herein shall consist of this specification sheet, MIL-DTL-32385, and QPL-32385. INTENDED USE: 1. The connectors covered by this specification sheet are intended for use on control and instrument panels for aircraft, ground, and shipboard applications. REQUIRE

3、MENTS: 1. Material: Material shall be in accordance with MIL-DTL-32385. 2. Finish: Finish shall be in accordance with MIL-DTL-32385. 3. Design: Design shall be in accordance with MIL-DTL-32385. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-

4、32385/1 2 NOTES: 1. The part or identifying number (PIN) consists of the letters MS, the specification number, and the dash number taken from table 1. MS 90335 - X Dash number (see table I) Specification number MS prefix (Retaining MS part number) TABLE I. Dash number PIN cross-reference data. Dash

5、number 1MS90335D PIN MIL-DTL-32385/2 PIN -1 MS90335-1 MS90335-1 -2 MS90335-2 MS90335-2 1See figure 1. 2. Interpret figure in accordance with ASME Y14.5. 3. When mated with MIL-DTL-32385/5, or /6 plug that has been inserted to a depth of 0.140 0.005 inch, the connector shall have a minimum withdrawal

6、 force of 3 pounds of force (lbf) and a maximum withdrawal force of 10 lbf. 4. The manufacturers identification mark shall be permanently stamped in the metal part of the connectors. 5. The current loading of the connectors is limited to the current-carrying capacity of the wire used in the associat

7、ed interconnecting cabling. 6. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. 7. Unless otherwise specified, issues of reference documents are those in effect at the time of solicitation. 8. Interchangeability

8、 relationship: MS90335-1 and MIL-DTL-32385/1-1 parts are universally, functionally and dimensionally interchangeable. MS90335-2 and MIL-DTL-32385/1-2 parts are universally, functionally and dimensionally interchangeable. Provided by IHSNot for ResaleNo reproduction or networking permitted without li

9、cense from IHS-,-,-MIL-DTL-32385/1 3 FIGURE 1. Connector, receptacle, center contact positive, panel ground type. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32385/1 4 NOTES: 1. All dimensions are in inches. 2. Tolerances: Dimensions 0.00

10、5 unless otherwise specified. 3. Female center contact fingers closed down uniformly to meet 4 ounces minimum withdrawal force with 0.079 diameter pin before and after 3 insertions of a 0.082 diameter pin. 4. Captivation of insulator and center contact will maintain 12 lbf when applied from interfac

11、e end. 5. Insulator shall not exceed diameter of body. 6. Angular dimension of 2.5 degrees. FIGURE 1. Connector, receptacle, center contact positive, panel ground type - Continued. Custodians: Preparing Activity: Army - AV Navy - AS Air Force - 85 DLA - GS DLA - GS2 (Project 5935-2011-031) Review Ac

12、tivities: Navy - MC, SH NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • DIN 58967-30-1999 Diagnostics of infectious diseases and diseases of the immune systems in serological and molecularbiology - Part 30 ELISA (Enzyme-Linked-Immuno-Sorbent-Assay) ter.pdf DIN 58967-30-1999 Diagnostics of infectious diseases and diseases of the immune systems in serological and molecularbiology - Part 30 ELISA (Enzyme-Linked-Immuno-Sorbent-Assay) ter.pdf
  • DIN 58967-40-1994 Serodiagnosis of infectious diseases and diseases of the immune system immunoblot (IB) part 40 terms general method-specific requirements《传染病和免疫性疾病的血清诊断 免疫缺陷(IB) .pdf DIN 58967-40-1994 Serodiagnosis of infectious diseases and diseases of the immune system immunoblot (IB) part 40 terms general method-specific requirements《传染病和免疫性疾病的血清诊断 免疫缺陷(IB) .pdf
  • DIN 58967-60-2001 Diagnostics of infectious deseases and deseases of the immune system in serology and molecular biology - Part 60 Polymerase chain reaction (PCR) Terminology gener.pdf DIN 58967-60-2001 Diagnostics of infectious deseases and deseases of the immune system in serology and molecular biology - Part 60 Polymerase chain reaction (PCR) Terminology gener.pdf
  • DIN 58968-20-1990 Immunology serodiagnosis of immune diseases indirect immunofluorescence test special requirements for the detection of autoantibodies《免疫学 免疫性疾病的血清诊断 第20部分 间接免疫荧光试.pdf DIN 58968-20-1990 Immunology serodiagnosis of immune diseases indirect immunofluorescence test special requirements for the detection of autoantibodies《免疫学 免疫性疾病的血清诊断 第20部分 间接免疫荧光试.pdf
  • DIN 58969-10-2003 Medical microbiology - Diagnostics of infectious diseases in serological and molecular biology - Part 10 Complement fixation test (CFT)《医用微生物学 血清学和分子生物学中传染性疾病的诊断 .pdf DIN 58969-10-2003 Medical microbiology - Diagnostics of infectious diseases in serological and molecular biology - Part 10 Complement fixation test (CFT)《医用微生物学 血清学和分子生物学中传染性疾病的诊断 .pdf
  • DIN 58969-41-1994 Medical microbiology serodiagnosis of infectious diseases immunoblot (IB) part 41 special requirements for the detection of antibodies against Human Immunodeficie.pdf DIN 58969-41-1994 Medical microbiology serodiagnosis of infectious diseases immunoblot (IB) part 41 special requirements for the detection of antibodies against Human Immunodeficie.pdf
  • DIN 58969-44-2005 Medical microbiology - Diagnostics of infectious diseases in serology and molecular biology - Part 44 Immunoblot (IB) Special requirements for the detection of an.pdf DIN 58969-44-2005 Medical microbiology - Diagnostics of infectious diseases in serology and molecular biology - Part 44 Immunoblot (IB) Special requirements for the detection of an.pdf
  • DIN 58969-61-1997 Medical microbiology - Serodiagnosis of infectious diseases - Part 61 Polymerase chain reaction (PCR) special requirements for the detection of nucleic acid seque.pdf DIN 58969-61-1997 Medical microbiology - Serodiagnosis of infectious diseases - Part 61 Polymerase chain reaction (PCR) special requirements for the detection of nucleic acid seque.pdf
  • DIN 58970-1-1996 Laboratory centrifuges - Part 1 Definitions testing marking《试验室用离心机 第1部分 定义、测试、标记》.pdf DIN 58970-1-1996 Laboratory centrifuges - Part 1 Definitions testing marking《试验室用离心机 第1部分 定义、测试、标记》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1