1、AMSC N/A FSC 5930 INCH-POUND MIL-DTL-3786/5H 26 January 2011 SUPERSEDING MIL-DTL-3786/5G 19 November 2004 DETAIL SPECIFICATION SHEET SWITCH, ROTARY, OPEN CONSTRUCTION, .200 AMPERE, STYLE SR05 Inactive for new design after 8 March 1999 This specification is approved for use by all Departments and Age
2、ncies of the Department of Defense. The complete requirements for acquiring the switch described herein shall consist of this specification and MIL-DTL-3786. FIGURE 1. Style SR05 switch. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/5H
3、 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .015 (0.38 mm). 4. The number of sections is as selected from table III. 5. Nonturn device as shown is not applicable to S construction switches. 6. Inner
4、shaft stop strength 4 inch-pounds. Outer shaft stop strength 15 inch pounds. 7. Shaft-flat angle A is the angle between a line through the center of the shaft and center of the nonturn device, and another line through the center of the shaft and perpendicular to the shaft flat. For construction S sw
5、itches, the bushing flat is the nonturn device. Angle A is 270. 8. Shaft shown in maximum counterclockwise position for switches with stops, and with switch in position number 1 for switches without stops. 9. Front plate design optional provided it falls within the maximum outside diameter of the se
6、ction dimension referenced. 10. Terminal tabs may be bent to the rear at an angle up to 75 from the plane of the section. 11. Marking plate is included with all switches. FIGURE 1. Style SR05 switch - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
7、m IHS-,-,-MIL-DTL-3786/5H 3 FIGURE 2. Circuit diagrams - viewed from front or knob end with switch in extreme counterclockwise position. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/5H 4 NOTE: For switches with fewer than maximum numb
8、er of positions, short clips will be omitted from clockwise end of rotation. FIGURE 2. Circuit diagrams - viewed from front or knob end with switch in extreme counterclockwise position - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-
9、DTL-3786/5H 5 REQUIREMENTS: Dimensions and configuration: See figures 1 and 2. Construction type: See table I. Angle of throw: See table II. Mounting hardware: Each switch shall be supplied with two hexagon nuts in accordance with MS25082-20, and one internal-tooth lock washer in accordance with NAS
10、M35333-42. Insulation material: See table II. Number of poles per deck: See table III. Number of decks: See table IV. Number of positions: See table III. Switching characteristics: See table IV. Temperature-life characteristics: See table I. Altitude: Symbol C (70,000 feet). Rotational-torque: 0.75
11、inch-pound minimum, 4 inch-pound maximum at room temperature. 0.75 inch-pound minimum, 6 inch-pound maximum at minimum temperature. Terminal strength (pull): A force of 2 pounds shall be applied to the terminals. Contact resistance: At room temperature: Initial and after vibration and shock: 20 mill
12、iohms, maximum. After moisture-resistance and salt spray: 30 milliohms, maximum. After initial soak and completion of life test: 40 milliohms, maximum. Vibration grade: Symbol 3 (10 to 2000 Hz). Shock type: See table I. Dielectric withstanding voltage: At atmospheric pressure: 750 volts, rms. At red
13、uced barometric pressure: 375 volts, rms. Life (rotational): The test loads for the applicable circuit conditions shall be as specified in table V. Each of the loads specified for the applicable environmental condition shall be switched by at least one rotor contact of the switch. Provided by IHSNot
14、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/5H 6 Part or Identifying Number (PIN): The military pin shall consists of M3786/5- (four letters selected from tables I through IV) as shown in the following example: M3786/5- A D E C Construction type, temp
15、erature-life characteristic and shock type (see table I) Insulation material and angle of throw (see table II) Poles per deck and number of positions (see table III) Number of decks and switching characteristics (see table IV) Pins shall be generated only to identify switches shown on figure 2. Acqu
16、iring switches not identified by military pins shall be in accordance with the ordering data of MIL-DTL-3786. Application. To conserve material, space, and weight, the following is suggested: Two-position and three-position switches with 30 angle of throw should be four poles per deck. Four-position
17、 switches with 30 angle of throw should be three poles per deck. Five- and six-position switches with 30 angle of throw should be two poles per deck. Two-, three-, four-, and five-position switches with 36 angle of throw should be two poles per deck. Two-, three-, and four-position switches with 45
18、angle of throw should be two poles per deck. Two- and three-position switches with 60 angle of throw should be two poles per deck. M3786/5-ADEC identifies a rotary switch of construction type N, temperature-life characteristic B, shock types H and M, ceramic or glass bonded mica insulation material,
19、 36 degree angle of throw, 1 pole per deck, 5 positions, 2 decks, and nonshorting switching characteristic. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/5H 7 TABLE I. Code letter for combination of construction type, temperature-life
20、characteristic, and shock typeCode letter . Construction type 1/ 2/ Temperature-life characteristic Shock type A N B H and M B S B H and M C N C H and M D S C H and M E N D H and M F S D H and M G N B M H S B M J N C M K S C M L N D M M S D M 1/ Construction type N identifies an open construction sw
21、itch, without a sealed shaft and panel seal. 2/ Construction type S is an open construction switch, with a sealed shaft and panel seal. TABLE II. Code letter for combinations of insulation material and angle of throwCode letter . Insulation material Angle of throw Code letter Insulation material Ang
22、le of throw A C 30 J P 45 B G 30 K C 60 C P 30 L G 60 D C 36 M P 60 E G 36 N C 90 F P 36 P G 90 G C 45 Q P 90 H G 45 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/5H 8 TABLE III. Code letters for combination of poles per deck and numbe
23、r of positionsCode letter . Poles per deck Number of positions Code letter Poles per deck Number of positions A 1 C 1/ M 1 12 B 1 2 N 2 2 C 1 3 P 2 3 D 1 4 Q 2 4 E 1 5 R 2 5 F 1 6 S 2 6 G 1 7 T 3 2 H 1 8 U 3 3 J 1 9 V 3 4 K 1 10 W 4 2 L 1 11 X 4 3 1/ Switch is continuous rotation type (no stops), an
24、d number of positions is dependent of angle of throw as follows: Angle of throw 30 12 Positions 36 10 45 8 60 6 90 4 TABLE IV. Code letter for combinations of number of decks and switching characteristicsCode . Number Switching characteristics letter of decks First deck Second deck Third deck Fourth
25、 deck Fifth deck Sixth deck A 1 NS B 1 S C 2 NS NS D 2 S S E 2 NS S F 3 NS NS NS G 3 S S S H 3 NS NS S J 3 NS S S K 4 NS NS NS NS L 4 S S S S M 4 NS NS NS S N 4 NS S S S P 5 NS NS NS NS NS Q 5 S S S S S R 5 NS NS NS NS S S 5 NS S S S S T 4 NS NS S S U 5 NS NS NS S S TABLE IV. Code letter for combina
26、tions of number of decks and switching characteristics - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3786/5H 9 Code Number Switching characteristics letter of decks First deck Second deck Third deck Fourth deck Fifth deck Sixth
27、 deck V 5 NS NS S S S W 6 NS NS NS NS NS NS X 6 S S S S S S Y 6 NS NS NS NS NS S Z 6 NS NS NS NS S S 1 6 NS NS NS S S S 2 6 NS NS S S S S 3 6 NS S S S S S TABLE V. Electrical loadsEnvironmental condition . Inductive load Resistive loads Milliamperes Volts, dc Milliamperes Volts, dc At atmospheric pr
28、essure 20 28 200 28 dc 100 115 rms At reduced barometric pressure - - 100 28 dc 50 115 rms The margins of this specification are marked with vertical lines to indicate where modifications from this revision were made. This was done as a convenience only and the Government assumes no liability whatso
29、ever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations. Reference Documents: MIL-DTL-3786 Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air For
30、ce - 85 (Project 5930-2011-008) DLA CC Review activities: Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-