1、AMSC N/A FSC 5985 MIL-DTL-3922/56D 5 January 2010 SUPERSEDING MIL-DTL-3922/56C 6 March 2000 DETAIL SPECIFICATION SHEET FLANGES, WAVEGUIDE (COVER) (ROUND, 8 HOLE) This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The requirements for acquiring the

2、flanges described herein shall consist of this document and the latest issue of MIL-DTL 3922. NOTES: 1. Dimensions are in inches. 2. Metric equivalents (to the nearest 0.01 mm) are given for general information only and are based upon 1.00 inch = 25.4 mm. 3. Metric equivalents are in parentheses. 4.

3、 Roughness of mating surfaces shall not exceed 63 microinches in accordance with ASME B46.1, except that flaws shall be included in the roughness height measurement. FIGURE 1. Flange configuration. INCH-POUND Inches mm .002 0.05 .003 0.08 .004 0.10 .015 0.38 .062 1.57 .125 3.18 .313 7.95 Provided by

4、 IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3922/56D 2 TABLE I. Dash number and dimensions. PIN M3922/56- 1/ Dimensions Dash Used with A B C D E F G H J K L M no. Waveguide M85/1- Mating flange M3922/61-+.003 (0.08) -.000 +.003 (0.08) -.000 .015 (0.

5、38) BSC Max Rad +.003(0.08)-.000.015 (0.38) .015(0.38).015 (0.38) .015 (0.38) Nom .015(0.38)001 2/ 043 002 3.007 1.507 5.313 4.750 .062 .257 3.500 .250 .750 3.375 2.000 1.875002 3/ 041 001 (76.38) (38.28) (134.95) (120.65) (1.57) (6.53) (88.90) (6.35) (19.05) (85.73) (50.80) (47.63)1/ Dimensions are

6、 in inches (millimeters are in parentheses). 2/ Copper alloy. 3/ Aluminum alloy. REQUIREMENTS: Dimensions and configuration: See figure 1 and table I. Material: Metallic alloy as specified in table I. Marking: See figure 1. Part or Identifying Number (PIN): M3922/56- (and PIN from table I). TABLE II

7、 Cross-reference and engineering information. PIN M3922/56- AN nomenclature Frequency range (GHz) 001 002 UG-53/U UG-584/U 2.60-3.95 2.60-3.95 Referenced documents. In addition to MIL-DTL-3922, this specification sheet references the following documents: ASME-B46.1 Marginal notations are not used i

8、n this revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5985-2009-036) DLA - CC Review activities: Army - AV, MI Navy - AS, MC, OS Air Force - 99 NOTE: The activities

9、 listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS IEC 60287-2-3-2017 Electric cables Calculation of the current rating Thermal resistance Cables installed in ventilated tunnels《电缆 当前评级的计算 热阻 通风隧道中安装的电缆》.pdf BS IEC 60287-2-3-2017 Electric cables Calculation of the current rating Thermal resistance Cables installed in ventilated tunnels《电缆 当前评级的计算 热阻 通风隧道中安装的电缆》.pdf
  • BS IEC 60287-3-1-2017 Electric cables Calculation of the current rating Operating conditions Site reference conditions《电缆 电流额定的计算 第3-1部分 操作条件 现场参考条件》.pdf BS IEC 60287-3-1-2017 Electric cables Calculation of the current rating Operating conditions Site reference conditions《电缆 电流额定的计算 第3-1部分 操作条件 现场参考条件》.pdf
  • BS IEC 60287-3-2-2012 Electric cables Calculation of the current rating Sections on operating conditions Economic optimization of power cable size《电缆 额定电流的计算 操作条件部分 电力电缆尺寸的经济优化》.pdf BS IEC 60287-3-2-2012 Electric cables Calculation of the current rating Sections on operating conditions Economic optimization of power cable size《电缆 额定电流的计算 操作条件部分 电力电缆尺寸的经济优化》.pdf
  • BS IEC 60287-3-3-2007 Electric cables - Calculation of the current rating - Sections on operating conditions - Cables crossing external heat sources《电缆 额定电流的计算 运行条件章节 横越外部热源的电缆》.pdf BS IEC 60287-3-3-2007 Electric cables - Calculation of the current rating - Sections on operating conditions - Cables crossing external heat sources《电缆 额定电流的计算 运行条件章节 横越外部热源的电缆》.pdf
  • BS IEC 60300-3-10-2001 Dependability management - Application guide - Maintainability《可靠性管理 应用指南 维修性》.pdf BS IEC 60300-3-10-2001 Dependability management - Application guide - Maintainability《可靠性管理 应用指南 维修性》.pdf
  • BS IEC 60300-3-5-2001 Dependability management - Application guide - Application guide - Reliability test conditions and statistical test principles《可靠性管理 应用指南 可靠性试验条件和统计试验原则》.pdf BS IEC 60300-3-5-2001 Dependability management - Application guide - Application guide - Reliability test conditions and statistical test principles《可靠性管理 应用指南 可靠性试验条件和统计试验原则》.pdf
  • BS IEC 60300-3-6-1998 Dependability management - Application guide - Software aspects of dependability《相依性管理 应用指南 软件相依性特点》.pdf BS IEC 60300-3-6-1998 Dependability management - Application guide - Software aspects of dependability《相依性管理 应用指南 软件相依性特点》.pdf
  • BS IEC 60300-3-7-1999 Dependability management - Application guide - Application guide - Reliability stress screening of electronic hardware《可靠性管理 应用指南 电子硬件的可靠性应力筛选》.pdf BS IEC 60300-3-7-1999 Dependability management - Application guide - Application guide - Reliability stress screening of electronic hardware《可靠性管理 应用指南 电子硬件的可靠性应力筛选》.pdf
  • BS IEC 60313-2002 Coaxial connectors used in nuclear laboratory instrumentation《核实验室仪器用的同轴电缆连接器》.pdf BS IEC 60313-2002 Coaxial connectors used in nuclear laboratory instrumentation《核实验室仪器用的同轴电缆连接器》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1