DLA MIL-DTL-3933 19 C-2011 ATTENUATORS FIXED SPACE LEVEL NON SPACE LEVEL COAXIAL LINE (BNC CONNECTORS) FREQUENCY RANGE DC TO 4 5 GHZ CLASS III LOW POWER.pdf

上传人:feelhesitate105 文档编号:690743 上传时间:2018-12-30 格式:PDF 页数:5 大小:50.62KB
下载 相关 举报
DLA MIL-DTL-3933 19 C-2011 ATTENUATORS FIXED SPACE LEVEL NON SPACE LEVEL COAXIAL LINE (BNC CONNECTORS) FREQUENCY RANGE DC TO 4 5 GHZ CLASS III LOW POWER.pdf_第1页
第1页 / 共5页
DLA MIL-DTL-3933 19 C-2011 ATTENUATORS FIXED SPACE LEVEL NON SPACE LEVEL COAXIAL LINE (BNC CONNECTORS) FREQUENCY RANGE DC TO 4 5 GHZ CLASS III LOW POWER.pdf_第2页
第2页 / 共5页
DLA MIL-DTL-3933 19 C-2011 ATTENUATORS FIXED SPACE LEVEL NON SPACE LEVEL COAXIAL LINE (BNC CONNECTORS) FREQUENCY RANGE DC TO 4 5 GHZ CLASS III LOW POWER.pdf_第3页
第3页 / 共5页
DLA MIL-DTL-3933 19 C-2011 ATTENUATORS FIXED SPACE LEVEL NON SPACE LEVEL COAXIAL LINE (BNC CONNECTORS) FREQUENCY RANGE DC TO 4 5 GHZ CLASS III LOW POWER.pdf_第4页
第4页 / 共5页
DLA MIL-DTL-3933 19 C-2011 ATTENUATORS FIXED SPACE LEVEL NON SPACE LEVEL COAXIAL LINE (BNC CONNECTORS) FREQUENCY RANGE DC TO 4 5 GHZ CLASS III LOW POWER.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A FSC 5985 MIL-DTL-3933/19C 15 August 2011 SUPERSEDING MIL-DTL-3933/19B 7 November 2002 DETAIL SPECIFICATION SHEET ATTENUATORS, FIXED, SPACE LEVEL, NON SPACE LEVEL, COAXIAL LINE (BNC CONNECTORS), FREQUENCY RANGE: DC TO 4.5 GHZ, CLASS III, LOW POWER This specification is approved for use by a

2、ll Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-3933. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Metric equivalents ar

3、e in parentheses. FIGURE 1. Dimensions and configuration. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3933/19C 2 ENGINEERING DATA: Operating frequency range: DC to 4.5 GHz. Test frequency range for SWR and attenuation measureme

4、nts, measured or recorded, when using an Automatic Network Analyzer (ANA) or equivalent test equipment: 100 MHz (or lower) to 4.5 GHz. Basic test frequency for sensitive measurements like connector repeatability, temperature sensitivity, power sensitivity and any other measurements where a delta spe

5、cification is imposed: 2.0 GHz. Operating temperature range: -55C to 125C. Maximum weight: See table I. REQUIREMENTS: Qualification: Not required. First Article Testing shall be in accordance with the qualification inspection table of MIL-DTL-3933. Dimensions and configuration: See figure 1 and tabl

6、e I. Nominal impedance: 50 ohms. Attenuation: See table I. Stability and sensitivity: Maximum change in attenuation after: up to 10 dB, inclusive (dB) over 10 dB (dB/dB) Temperature change or thermal shock 0.05 0.005 Vibration or shock 0.1 0.01 Moisture resistance or salt spray 0.2 0.02 Peak power 0

7、05 0.005 Frequency sensitivity, maximum: 0.1dB/dB/GHz. Temperature sensitivity of attenuation, maximum: 0.0004 dB/dB/C. Power rating: See table I. Power sensitivity for full input power, maximum: 0.005 dB/dB/Watt. VSWR: See table I. Connector repeatability, maximum variation in attenuation: 0.02 dB

8、 Part or Identifying Number (PIN): M3933/19- (and dash number from table I with three device level designators are space level (T), screened (S) and non-screened (N) options). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3933/19C 3 TABLE

9、I. Electrical characteristics. Dash number Attenuation dB Maximum power input at 25C VSWR maximum 1/ Weight (oz) Maximum Dimension A (inches) Maximum Nominal Deviation DC to 1.0 GHz 1.0 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.5 GHz DC to 4.5 GHz AV (W) 2/ (continuously) Peak (kW) 3/ 01 N S T 1 0.3 4 0.5

10、1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 02 N S T 2 0.3 4 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 03 N S T 3 0.3 4 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 04 N S T 4 0.3 3 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 05 N S T 5 0.3 3 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 06 N S T 6

11、0.3 3 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 07 N S T 8 0.5 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 08 N S T 10 0.5 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 09 N S T 11 0.5 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 10 N S T 12 0.5 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6

12、) 11 N S T 15 0.5 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) See footnotes at end of table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3933/19C 4 TABLE I. Electrical characteristics - Continued. Dash number Attenuation dB Maximum p

13、ower input at 25C VSWR maximum 1/ Weight (oz) Maximum Dimension A (inches) Maximum Nominal Deviation DC to 1.0 GHz 1.0 to 2.0 GHz 2.0 to 3.0 GHz 3.0 to 4.5 GHz DC to 4.5 GHz AV (W) 2/ (continuously) Peak (kW) 3/ 12 N S T 20 0.5 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 13 N S T 25 0.9 2 0.5 1.1

14、0:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 14 N S T 30 0.9 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 15 N S T 40 0.9 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 3.0 (76.2) 16 N S T 50 1.2 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 3.0 (76.2) 17 N S T 60 1.4 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 3.0 (76.2) 18 N S T 1

15、3 0.5 2 0.5 1.10:1 1.15:1 1.20:1 1.25:1 4 2.7 (68.6) 1/ VSWR value is for both ends. 2/ Power input is derated linearly to 0.5 watts at +125C. 3/ Peak power for a duty cycle of 5 x 10-4; maximum pulse duration of 5 microseconds. Referenced documents. In addition to MIL-DTL-3933 this specification sh

16、eet references the following documents: Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3933/19C 5 MIL-PRF-39012/16 MIL-PRF-39012/17 Marginal notations are not used in this revision to identify changes with respect to the previous issue due t

17、o the extent of the changes. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5985-2010-017) NASA - NA DLA - CC Review activities: Army - MI Navy - AS, MC, SH Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf