DLA MIL-DTL-3933 31-2010 ATTENUATORS FIXED COAXIAL CONNECTOR SPACE LEVEL NON SPACE LEVEL TYPE 3 5 mm CONNECTOR FREQUENCY RANGE DC TO 28 GHz CLASS III LOW POWER.pdf

上传人:feelhesitate105 文档编号:690747 上传时间:2018-12-30 格式:PDF 页数:4 大小:32.57KB
下载 相关 举报
DLA MIL-DTL-3933 31-2010 ATTENUATORS FIXED COAXIAL CONNECTOR SPACE LEVEL NON SPACE LEVEL TYPE 3 5 mm CONNECTOR FREQUENCY RANGE DC TO 28 GHz CLASS III LOW POWER.pdf_第1页
第1页 / 共4页
DLA MIL-DTL-3933 31-2010 ATTENUATORS FIXED COAXIAL CONNECTOR SPACE LEVEL NON SPACE LEVEL TYPE 3 5 mm CONNECTOR FREQUENCY RANGE DC TO 28 GHz CLASS III LOW POWER.pdf_第2页
第2页 / 共4页
DLA MIL-DTL-3933 31-2010 ATTENUATORS FIXED COAXIAL CONNECTOR SPACE LEVEL NON SPACE LEVEL TYPE 3 5 mm CONNECTOR FREQUENCY RANGE DC TO 28 GHz CLASS III LOW POWER.pdf_第3页
第3页 / 共4页
DLA MIL-DTL-3933 31-2010 ATTENUATORS FIXED COAXIAL CONNECTOR SPACE LEVEL NON SPACE LEVEL TYPE 3 5 mm CONNECTOR FREQUENCY RANGE DC TO 28 GHz CLASS III LOW POWER.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5985 MIL-DTL-3933/31 10 August 2010 DETAIL SPECIFICATION SHEET ATTENUATORS, FIXED COAXIAL CONNECTOR SPACE LEVEL, NON SPACE LEVEL TYPE 3.5 mm CONNECTOR FREQUENCY RANGE: DC TO 28 GHz, CLASS III, LOW POWER This specification is approved for use by all Departments and Agencies of the Depart

2、ment of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-3933. NOTES: 1. Dimension A, 1.30 0.02 (33 0.5). 2. Dimensions are in inches. 3. Metric equivalents are given in parentheses for general information only. FIGURE 1. Dime

3、nsions and configuration. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3933/31 2 ENGINEERING DATA: Operating frequency range: DC to 28 gigahertz (GHz) (see table I). Test frequency range for SWR and attenuation measurements, mea

4、sured or recorded, when using an Automatic Network Analyzer (ANA) or equivalent test equipment: 100 MHz (or lower) to 14 GHz. Basic test frequency for sensitive measurements like temperature sensitivity, power sensitivity, and any other measurements where a delta specification is imposed: 14 GHz. Op

5、erating temperature range: -55 C to +100 C Weight: 0.30 ounces (8 g) maximum. REQUIREMENTS: Dimensions and configuration: See figure 1. Nominal impedance: 50 ohms. Attenuation: See table I. Stability and sensitivity: Maximum attenuation change after: Up to 10 dB, inclusive (dB) Over 10 dB (dB/dB) Te

6、mperature change/ thermal shock 0.05 0.005 Vibration or shock 0.1 0.01 Moisture resistance or salt spray 0.2 0.02 Peak power 0.05 0.005 Temperature sensitivity of attenuation, maximum: 0.0004 dB/dB/C. Power: See table I. Power sensitivity for full input power, maximum: 0.004 dB/dB/Watt. VSWR: See ta

7、ble I. Part or Identifying Number (PIN): M3933/31- (and dash number from table I with three device level designators are space level (T), screened (S) and non-screened (N) options). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-AMSC N/A FSC 5985 TA

8、BLE I. Electrical characteristics. Dash Number Attenuation (dB) Maximum power Input VSWR maximum 1/ Dimension A in inches (mm) 0.02 (0.5) Nominal Deviation DC to 8 GHz 8 to 12.4 GHz 12.4 to 28 GHz DC to 28 GHz AV (W) at 25C 2/ (continuously) Peak 3/ kW 01 N S T 0 +0.5, - 0 2 0.5 1.10:1 1.15:1 1.25:1

9、 1.30 (33) 02 N S T 3 0.60 2 0.5 1.10:1 1.15:1 1.25:1 1.30 (33) 03 N S T 6 0.60 2 0.5 1.10:1 1.15:1 1.25:1 1.30 (33) 04 N S T 10 0.60 2 0.5 1.10:1 1.15:1 1.25:1 1.30 (33) 05 N S T 20 0.75 2 0.5 1.10:1 1.15:1 1.25:1 1.30 (33) 06 N S T 30 0.75 2 0.5 1.10:1 1.15:1 1.25:1 1.30 (33) 1/ VSWR value is for

10、both ends. 2/ Power rating derated linearly to 0.2 Watts at 1000C. 3/ Peak power: 500 watts at 5 x 10-4 duty cycle, 5 microsecond pulsewidth.MIL-DTL-3933/313Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-3933/31 4 Referenced documents. This

11、specification sheet only references MIL-DTL-3933. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5985-2010-006) DLA - CC Review activities: Army - MI Navy - AS, MC, SH Air Force - 99 Civil agencies: NASA - NA NOTE: The activities listed above were interested in

12、this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ANSI IEEE 987-2001 Guide for Application of Composite Insulators《复合绝缘体的应用指南》.pdf ANSI IEEE 987-2001 Guide for Application of Composite Insulators《复合绝缘体的应用指南》.pdf
  • ANSI IEEE 991-1986 Logic Circuit Diagrams《逻辑线路图》.pdf ANSI IEEE 991-1986 Logic Circuit Diagrams《逻辑线路图》.pdf
  • ANSI IEEE 11073-10102-2012 Health informatics-Point-of-care medical device communication Part 10102 Nomenclature-Annotated ECG.pdf ANSI IEEE 11073-10102-2012 Health informatics-Point-of-care medical device communication Part 10102 Nomenclature-Annotated ECG.pdf
  • ANSI IEEE 11073-10406-2011 Health informatics Personal health device communication Part 10406 Device specialization Basic electrocardiograph (ECG) (1- to 3-lead ECG)《健康信息学.个人保健装置通信.pdf ANSI IEEE 11073-10406-2011 Health informatics Personal health device communication Part 10406 Device specialization Basic electrocardiograph (ECG) (1- to 3-lead ECG)《健康信息学.个人保健装置通信.pdf
  • ANSI IEEE 11073-10418 CORR 1-2015 Health informatics-Personal health device communication Part 10418 Device specialization-International Normalized Ratio (INR) monitor Corrigendum .pdf ANSI IEEE 11073-10418 CORR 1-2015 Health informatics-Personal health device communication Part 10418 Device specialization-International Normalized Ratio (INR) monitor Corrigendum .pdf
  • ANSI IEEE 11073-10418-2011 Health informatics Personal health device communication Part 10418 Device specialization International Normalized Ratio (INR) monitor《健康信息学.个人健康装置通信.装置专业.pdf ANSI IEEE 11073-10418-2011 Health informatics Personal health device communication Part 10418 Device specialization International Normalized Ratio (INR) monitor《健康信息学.个人健康装置通信.装置专业.pdf
  • ANSI IEEE 11073-10420-2010 Health informatics Personal health device communication Part 10420 Device specialization-Body composition analyzer《健康信息学.个人健康设备通讯.设备规范.身体组成分析仪》.pdf ANSI IEEE 11073-10420-2010 Health informatics Personal health device communication Part 10420 Device specialization-Body composition analyzer《健康信息学.个人健康设备通讯.设备规范.身体组成分析仪》.pdf
  • ANSI IEEE 11073-10421-2010 Health informatics Personal health device communication Part 10421 Device specialization Peak expiratory flow monitor (peak flow)《健康信息学.个人保健设备通信.设备规范.峰呼气.pdf ANSI IEEE 11073-10421-2010 Health informatics Personal health device communication Part 10421 Device specialization Peak expiratory flow monitor (peak flow)《健康信息学.个人保健设备通信.设备规范.峰呼气.pdf
  • ANSI IEEE 11073-30200A-2011 Health informatics - Point-of-care medical device communication - Part 30200 Transport profile - Cable connected - Amendment 1.pdf ANSI IEEE 11073-30200A-2011 Health informatics - Point-of-care medical device communication - Part 30200 Transport profile - Cable connected - Amendment 1.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1