DLA MIL-DTL-49285 16 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL THREE INDIVIDUALLY SHIELDED PAIRS OF 22 AWG SOLID WIRE.pdf

上传人:boatfragile160 文档编号:690834 上传时间:2018-12-30 格式:PDF 页数:4 大小:70.56KB
下载 相关 举报
DLA MIL-DTL-49285 16 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL THREE INDIVIDUALLY SHIELDED PAIRS OF 22 AWG SOLID WIRE.pdf_第1页
第1页 / 共4页
DLA MIL-DTL-49285 16 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL THREE INDIVIDUALLY SHIELDED PAIRS OF 22 AWG SOLID WIRE.pdf_第2页
第2页 / 共4页
DLA MIL-DTL-49285 16 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL THREE INDIVIDUALLY SHIELDED PAIRS OF 22 AWG SOLID WIRE.pdf_第3页
第3页 / 共4页
DLA MIL-DTL-49285 16 A-2010 CABLE SPECIAL PURPOSE ELECTRICAL THREE INDIVIDUALLY SHIELDED PAIRS OF 22 AWG SOLID WIRE.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 MIL-DTL-49285/16A 31 March 2010 SUPERSEDING MIL-C-49285/16 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, THREE INDIVIDUALLY SHIELDED PAIRS OF 22 AWG SOLID WIRE This specification is approved for use by all Departments and Agencies of the Department of Defense. The r

2、equirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. FIGURE 1. Cable illustration. AMSC N/A FSC 6145 INCH-POUND Inactive for new design after 16 June 1997. Provided by IHSNot for ResaleNo reproduction or networking permitted without lice

3、nse from IHS-,-,-MIL-DTL-49285/16A 2 Engineering information: See table I. Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal capacitance between the conductor and the shield with one conductor tied to

4、 the shield Continuous working voltage Nominal capacitance between adjacent shields Continuous working voltage between adjacent shields Shield dc resistance 40 pF/ft (picofarads/foot) 77 pF/ft 300 V rms maximum between conductors 150 pF/ft 50 volts maximum 14 ohms/1,000 feet maximum TABLE II. Descri

5、ption, physical. Components Construction details Number of pairs Conductor type and wire size Conductor insulation Conductor insulation thickness Drain wire type and size Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile strength (jacket) Elongation (jacket) Overall c

6、abling lay length Three individually shielded Solid tinned copper 22 AWG Polyvinyl chloride 0.013 inch nominal thickness Solid tinned copper 22 AWG Polyvinyl chloride 0.037 inch 0.293 inch maximum outside diameter 2464 2,000 pounds per square inch minimum 150 percent minimum 2.0 twists per foot 10 p

7、ercent Cabled pair orientation. The position of the red and green pair shield shall determine the rotation direction for pair location (see figure 1). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/16A 3 TABLE III. Shield color code. P

8、air numbers Shield color 1stpair 2ndpair 3rdpair Red Green Blue REQUIREMENTS: Design and construction: (see table II and table III). Shield location and orientation. The polyester aluminum shield is to be located on the outer circumference of the pair, with the aluminum foil side outward. Insulation

9、 on the interior of the shield is to be complete with no aluminum available for contact. Drain wire location. The drain wire is to be spirally located between the noise reducing tape and the aluminum foil shield, and is to be in continuous contact with the aluminum surface of the foil shield and the

10、 noise reducing tape throughout the cable. Cable temperature rating. The cable temperature rating shall be -20C to +80C. Flammability. The cable shall pass UL 2556 flame test requirements. Shield integrity test.* Frequency Response * 100 kHz 114 dB below reference 500 kHz 105 dB below reference 1 MH

11、z 99 dB below reference 5 MHz 85 dB below reference 10 MHz 79 dB below reference 15 MHz 74 dB below reference 20 MHz 70 dB below reference 25 MHz 65 dB below reference 30 MHz 61 dB below reference 100 MHz 42 dB below reference * Any two readings may deviate to a value of 0.9 times the stated limits.

12、 * All values are a minimum numerical value. Fixture resonance will occur between 40 and 70 MHz. Crosstalk test limits. All values are minimums. Frequency (kHz) Near end crosstalk (dB) Far end crosstalk (dB) 40 58 58 70 56 55 100 54 53 1,000 55 52 Insulation resistance between shields: 100 megohms/1

13、000 feet minimum. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/16A 4 Durometer hardness. The cable jacket shall have a “Shore A” hardness of 82 5. Part or Identifying Number (PIN): The PIN shall be M49285/16. Changes from previous i

14、ssue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to

15、 evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. This document references MIL-DTL-49285 and UL 2556. CONCLUDING MATERIAL Custodians: Preparing activity: Army CR DLA - CC N

16、avy SH Air Force 85 DLA - CC Review activities: Army MI Air Force 99 (Project 6145-2009-020) DLA - IS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change. You should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM E2590-2008 Standard Guide for Conducting Hazard Analysis-Critical Control Point (HACCP) Evaluations.pdf ASTM E2590-2008 Standard Guide for Conducting Hazard Analysis-Critical Control Point (HACCP) Evaluations.pdf
  • ASTM E2590-2009 Standard Guide for Conducting Hazard Analysis-Critical Control Point (HACCP) Evaluations《进行危害分析和关键控制点(HACCP)评价的标准指南》.pdf ASTM E2590-2009 Standard Guide for Conducting Hazard Analysis-Critical Control Point (HACCP) Evaluations《进行危害分析和关键控制点(HACCP)评价的标准指南》.pdf
  • ASTM E2590-2015 Standard Guide for Conducting Hazard Analysis-Critical Control Point (HACCP) Evaluations《执行危害分析和关键控制点 (HACCP) 评估的标准指南》.pdf ASTM E2590-2015 Standard Guide for Conducting Hazard Analysis-Critical Control Point (HACCP) Evaluations《执行危害分析和关键控制点 (HACCP) 评估的标准指南》.pdf
  • ASTM E2591-2007 Standard Guide for Conducting Whole Sediment Toxicity Tests with Amphibians《用两栖动物进行整体沉积物毒性试验的标准指南》.pdf ASTM E2591-2007 Standard Guide for Conducting Whole Sediment Toxicity Tests with Amphibians《用两栖动物进行整体沉积物毒性试验的标准指南》.pdf
  • ASTM E2591-2007(2013) Standard Guide for Conducting Whole Sediment Toxicity Tests with Amphibians《用两栖动物进行全沉积毒性试验的标准指南》.pdf ASTM E2591-2007(2013) Standard Guide for Conducting Whole Sediment Toxicity Tests with Amphibians《用两栖动物进行全沉积毒性试验的标准指南》.pdf
  • ASTM E2592-2007 Standard Practice for Evaluating Cache Packaged Weight and Volume of Robots for Urban Search and Rescue《城市搜救用机器人高速缓冲存储器包装重量和体积的评估用标准实施规程》.pdf ASTM E2592-2007 Standard Practice for Evaluating Cache Packaged Weight and Volume of Robots for Urban Search and Rescue《城市搜救用机器人高速缓冲存储器包装重量和体积的评估用标准实施规程》.pdf
  • ASTM E2592-2016 Standard Practice for Evaluating Response Robot Capabilities Logistics Packaging for Urban Search and Rescue Task Force Equipment Caches《评估响应机器人能力的标准实施规程 物流 城市搜索和救援.pdf ASTM E2592-2016 Standard Practice for Evaluating Response Robot Capabilities Logistics Packaging for Urban Search and Rescue Task Force Equipment Caches《评估响应机器人能力的标准实施规程 物流 城市搜索和救援.pdf
  • ASTM E2593-2007e1 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers《工业用铂电阻温度计的精度验证的标准指南》.pdf ASTM E2593-2007e1 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers《工业用铂电阻温度计的精度验证的标准指南》.pdf
  • ASTM E2593-2011 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers《工业用铂电阻温度计的精确验证标准指南》.pdf ASTM E2593-2011 Standard Guide for Accuracy Verification of Industrial Platinum Resistance Thermometers《工业用铂电阻温度计的精确验证标准指南》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1