DLA MIL-DTL-49292 8-2013 CABLE ASSEMBLIES NONPRESSURE PROOF FIBER OPTIC MIL-DTL-83526 20 EXPANDED BEAM CONNECTOR METRIC.pdf

上传人:ideacase155 文档编号:690862 上传时间:2018-12-30 格式:PDF 页数:6 大小:71.13KB
下载 相关 举报
DLA MIL-DTL-49292 8-2013 CABLE ASSEMBLIES NONPRESSURE PROOF FIBER OPTIC MIL-DTL-83526 20 EXPANDED BEAM CONNECTOR METRIC.pdf_第1页
第1页 / 共6页
DLA MIL-DTL-49292 8-2013 CABLE ASSEMBLIES NONPRESSURE PROOF FIBER OPTIC MIL-DTL-83526 20 EXPANDED BEAM CONNECTOR METRIC.pdf_第2页
第2页 / 共6页
DLA MIL-DTL-49292 8-2013 CABLE ASSEMBLIES NONPRESSURE PROOF FIBER OPTIC MIL-DTL-83526 20 EXPANDED BEAM CONNECTOR METRIC.pdf_第3页
第3页 / 共6页
DLA MIL-DTL-49292 8-2013 CABLE ASSEMBLIES NONPRESSURE PROOF FIBER OPTIC MIL-DTL-83526 20 EXPANDED BEAM CONNECTOR METRIC.pdf_第4页
第4页 / 共6页
DLA MIL-DTL-49292 8-2013 CABLE ASSEMBLIES NONPRESSURE PROOF FIBER OPTIC MIL-DTL-83526 20 EXPANDED BEAM CONNECTOR METRIC.pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、1 MIL-DTL-49292/8 20 September 2013 DETAIL SPECIFICATION SHEET CABLE ASSEMBLIES, NONPRESSURE PROOF, FIBER OPTIC, MIL-DTL-83526/20 EXPANDED BEAM CONNECTOR, METRIC This specification is approved for use by all Depart- ments and Agencies of the Department of Defense. The requirements for acquiring the

2、product described herein shall consist of this specification sheet and MIL-DTL-49292. FIGURE 1. Outline drawing, cable assembly (hermaphroditic) fiber optic. AMSC N/A FSC 6020 METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49292/8 2 P

3、IN configuration: For cable assembly PIN configuration and insertion loss, see table I. TABLE I. Cable assembly PIN configurations and optical insertion loss. Cable assembly PIN M49292/8- Connector PIN M83526/ Cable PIN M85045/ Length “L“ (meters) Channels Mode Wavelength 30 nm 1/ Insertion loss max

4、 (dB) 2/ 2S1 20-05 30E2A 10.0 0.5 2 Single 1,310 2.01 2S2 20-05 30E2A 100.0 0.5 2 Single 1,310 2.05 2S3 20-05 30E2A 500.0 0.5 2 Single 1,310 2.25 2S4 20-05 30E2A 1000.0 0.5 2 Single 1,310 2.50 2S5 20-06 30E2A 10.0 0.5 2 Single 1,550 2.01 2S6 20-06 30E2A 100.0 0.5 2 Single 1,550 2.05 2S7 20-06 30E2A

5、500.0 0.5 2 Single 1,550 2.25 2S8 20-06 30E2A 1000.0 0.5 2 Single 1,550 2.50 2M1 20-05 8-B2A 10.0 0.5 2 Multi 850 / 1,300 1.54 / 1.52 2M2 20-05 8-B2A 100.0 0.5 2 Multi 850 / 1,300 1.88 / 1.65 2M3 20-05 8-B2A 500.0 0.5 2 Multi 850 / 1,300 3.38 / 2.25 2M4 20-05 8-B2A 1000.0 0.5 2 Multi 850 / 1,300 5.2

6、5 / 3.00 4S1 20-01 30E4A 10.0 0.5 4 Single 1,310 2.01 4S2 20-01 30E4A 100.0 0.5 4 Single 1,310 2.05 4S3 20-01 30E4A 500.0 0.5 4 Single 1,310 2.25 4S4 20-01 30E4A 1000.0 0.5 4 Single 1,310 2.50 4S5 20-03 30E4A 10.0 0.5 4 Single 1,550 2.01 4S6 20-03 30E4A 100.0 0.5 4 Single 1,550 2.05 4S7 20-03 30E4A

7、500.0 0.5 4 Single 1,550 2.25 4S8 20-03 30E4A 1000.0 0.5 4 Single 1,550 2.50 4M1 20-01 8-B4A 10.0 0.5 4 Multi 850 / 1,300 1.54 / 1.52 4M2 20-01 8-B4A 100.0 0.5 4 Multi 850 / 1,300 1.88 / 1.65 4M3 20-01 8-B4A 500.0 0.5 4 Multi 850 / 1,300 3.38 / 2.25 4M4 20-01 8-B4A 1000.0 0.5 4 Multi 850 / 1,300 5.2

8、5 / 3.00 1/ Multimode connectors can be used at two wavelengths, depending on the connector specified (see table I, column two). 2/ Cable assembly insertion loss shall include cable loss, connector loss and the loss of any required optical attenuation element(s) within each connector. PIN Example; M

9、49292/8-2S3 designates a two channel single mode fiber optic cable assembly consisting of: a M83526/20-05 connector on each end of an M85045/30E2A cable, 500 meters long, with an insertion loss of 2.25dB max at 1,310 nm 30 nm wavelength. REQUIREMENTS: Component parts: Connectors, (two required) shal

10、l be in accordance with M83526/20-XX, where XX indicates the connector configuration (2 or 4 channel and single mode or multimode (see MIL-DTL-83562/20 table V) and table I above). Dust cover assemblies shall be as specified in M83526/20 (included as part of the connector). Provided by IHSNot for Re

11、saleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49292/8 3 Cable designation shall be as follows, M85045/W-XYZ, where W is the specification sheet (either 8 (multimode) or 30 (single mode), X is either “B” or “E”, Y indicates the number of channels (2 or 4) and Z indi

12、cates fiber size (62.5/125 or 50/125) for multimode or coating diameter (250 or 500) for single mode), see table I above). Assembly: Assembly shall be in accordance with figures 1 and 2, and tables I and II, and shall pass the requirements of tables III, and IV. Length: Length shall be in accordance

13、 with table I. Cable connector termini termination pinout diagram and fiber buffer color: Cable connector termini termination pinout diagram shall be in accordance with figure 2. FIGURE 2. C1 to C2 cable connector termini termination pinout diagram. Weight: Maximum weight of the cable assembly shall

14、 be In accordance with table II. TABLE II Length vs. weight. Length “L“ (meters) Weight (kg) maximum 10.0 0.5 1.3 100.0 0.5 4.1 500.0 0.5 17.0 1000.0 0.5 33.0 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49292/8 4 Performance: Optical requ

15、irements: Insertion loss (maximum assembly attenuation) per channel shall be as specified in table I. Where cable assemblies can be used at multiple wavelengths, insertion loss shall be measured at all wavelengths. Measurements shall be made in accordance with TIA/EIA-455-171, test method B1 for mul

16、timode and method B# for single mode. Optical fiber bandwidth: For 62.5/125, 300 MHz at 850 nm 20nm and 600 MHz at 1300 nm 20 nm. For 50/125 fiber, 500 MHz-km at 850 nm 20 nm and 500 MHz-km at1,300 nm 20 nm . Crosstalk: When tested in accordance with TIA-455-42, the assembly cross talk characteristi

17、cs shall be no less than -60 dB. Thermal shock: Not applicable. Cable retention: The minimum cable retention (cable to connector pullout strength) shall be 182 kilograms (401 lbs). Fluid immersion: Not applicable. Temperature range: Operating: -46C (-51F) to +71C (160F). Storage: -57C (-71F) to + 85

18、C (185F). Salt fog: Not applicable. Part or Identifying Number (PIN) characteristics: See table I. Temperature cycling: The test cable assembly shall be tested in accordance with the following: Low temperature: MIL-STD-810, method 502, procedures I and II. High temperature: MIL-STD-810, method 501,

19、procedures I and II (constant temperature). NOTE: The minimum soak time at each storage and operating temperature shall be 2 hours. First article inspection shall consist of performing the inspections and optical tests specified in table III herein, in the sequence shown. Provided by IHSNot for Resa

20、leNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49292/8 5 TABLE III. First article inspection. Inspection 1/ Sample quantity Group I (5 units) Visual and mechanical Insertion loss 5 units 5 units Group II (5 units)2/ Bandwidth Crosstalk 5 units 5 units Group III (3 uni

21、ts) 3/ Cable seal flexing Cable retention Low pressure (altitude) Temperature cycling Dust Storage temperature Humidity 1 unit 2 units 1 unit 2 units 2 units 2 units 1 unit Group IV (2 units) 3/ Vibration Life 1 unit 1 unit 1/ All inspections to be performed in the order specified in each group. 2/

22、Units from group 1 after completion of inspections. 3/ 5 units from group II inspections shall be divided into 3 units for group III inspections and 2 units for group IV inspections. Group A inspection shall consist of performing the inspections and optical tests specified in table IV herein, in the

23、 sequence shown. TABLE IV. Group A inspection. Inspection Visual and mechanical Insertion loss Group B inspection: Not applicable. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49292/8 6 Reference documents: In addition to MIL-DTL-49292, th

24、is document references the following: MIL-STD-810 TIA-455-42 TIA/EIA-455-171 MIL-DTL-83526/20 Custodians: Preparing activity: Army - CR DLA - CC Navy - SH Air Force - 85 (Project 6020-2010-002) DLA - CC Review activities: Army - AR, AV, MI Navy - AS, CG, EC, MC Air Force - 99 NOTE: The activities li

25、sted above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf BS PD IEC TS 62763-2013_5284 Pilot function through a control pilot circuit using PWM (pulse width modulation) and a control pilot wire《通过控制导向线使用PWM (脉冲宽度调制) 的导向功能和控制导向线》.pdf
  • BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf BS ISO 8070-2007 Milk and milk products - Determination of calcium sodium potassium and magnesium contents - Atomic absorption spectrometric method《牛奶和奶制品 钙、钠、钾和镁含量的测定 原子吸.pdf
  • BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf BS ISO 8082-1-2009 Self-propelled machinery for forestry - Laboratory tests and performance requirements for roll-over protective structures - General machines《林业用自推进机械 防倾.pdf
  • BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf BS ISO 8082-2-2011 Self-propelled machinery for forestry Laboratory tests and performance requirements for roll-over protective structures Machines having a rotating platf.pdf
  • BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf BS ISO 8083-2006 Machinery for forestry - Falling-object protective structures (FOPS) - Laboratory tests and performance requirements《林业机械 落体防护装置(FOPS) 实验室试验和性能要求》.pdf
  • BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf BS ISO 8086-2004 Dairy plant - Hygiene conditions - General guidance on inspection and sampling procedures《乳品厂 卫生条件 检验和取样程序通用指南》.pdf
  • BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf BS ISO 8096-2005 Rubber- or plastics-coated fabrics for water resistant clothing - Specification《雨衣用橡胶或塑料涂覆织物 规范》.pdf
  • BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf BS ISO 8097-2001 Aircraft Minimum airworthiness requirements and test conditions for certified air cargo unit load devices《航空器 经认证的航空货运集装单元装置最低适航性要求和试验条件》.pdf
  • BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf BS ISO 8114-1993 Textile machinery and accessories - Spindles for ring-spinning and doubling machines - List of equivalent terms《纺织机械和附件 环锭纺纱机和并线机用锭子 同义术语表》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1