DLA MIL-DTL-52286 D-2010 CABLE ASSEMBLIES POWER ELECTRICAL (WITH MOLDED ON TERMINATIONS) GENERAL SPECIFICATION FOR.pdf

上传人:sofeeling205 文档编号:690882 上传时间:2018-12-30 格式:PDF 页数:55 大小:1.03MB
下载 相关 举报
DLA MIL-DTL-52286 D-2010 CABLE ASSEMBLIES POWER ELECTRICAL (WITH MOLDED ON TERMINATIONS) GENERAL SPECIFICATION FOR.pdf_第1页
第1页 / 共55页
DLA MIL-DTL-52286 D-2010 CABLE ASSEMBLIES POWER ELECTRICAL (WITH MOLDED ON TERMINATIONS) GENERAL SPECIFICATION FOR.pdf_第2页
第2页 / 共55页
DLA MIL-DTL-52286 D-2010 CABLE ASSEMBLIES POWER ELECTRICAL (WITH MOLDED ON TERMINATIONS) GENERAL SPECIFICATION FOR.pdf_第3页
第3页 / 共55页
DLA MIL-DTL-52286 D-2010 CABLE ASSEMBLIES POWER ELECTRICAL (WITH MOLDED ON TERMINATIONS) GENERAL SPECIFICATION FOR.pdf_第4页
第4页 / 共55页
DLA MIL-DTL-52286 D-2010 CABLE ASSEMBLIES POWER ELECTRICAL (WITH MOLDED ON TERMINATIONS) GENERAL SPECIFICATION FOR.pdf_第5页
第5页 / 共55页
点击查看更多>>
资源描述

1、Comments, suggestions, or questions on this document should be addressed to Defense Supply Center Richmond, ATTN: DSCR-VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616, or e-mailed to STDZNMGTdla.mil. Since contact information can change, you may want to verify the currency of this address

2、 information using the ASSIST database at https:/assist.daps.dla.mil/. AMSC N/A FSC 6150 INCH-POUND MIL-DTL-52286D 18 May 2010 SUPERSEDING MIL-C-52286C 28 April 1980 DETAIL SPECIFICATION CABLE ASSEMBLIES, POWER, ELECTRICAL (WITH MOLDED ON TERMINATIONS), GENERAL SPECIFICATION FOR Inactive for new des

3、ign after 9 December 2003. This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers cable assemblies with one or more molded-rubber terminals for interior and exterior power and lighting. 2. APPLICABLE DOCUMENT

4、S 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the

5、completeness of this list, document users are cautioned that they must meet all specified requirements of the documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specificati

6、ons, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-

7、DTL-52286D 2 FEDERAL SPECIFICATION TT-C-490 - Chemical Conversion Coatings and Pretreatments for Ferrous Surfaces (Base for Organic Coatings) COMMERCIAL ITEM DESCRIPTION A-A-2917 - Twine, Cotton, Seine DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-3432 - Cables, (Power and Special Purpose) and Wire,

8、Electrical (300 and 600 Volts) MIL-I-3930 - Insulating and Jacketing Compounds, Electrical (for Cables, Cords, and Wires), General Specification for DOD-P-15328 - Primer (Wash), Pretreatment (Formula No. 117 for Metals) (Metric) MIL-DTL-15659 - Terminal, Lug: Solder, Copper and Phosphor Bronze MIL-I

9、-24391 - Insulation Tape, Electrical, Plastic Pressure-Sensitive (See supplement 1 for list of specification sheets.) DEPARTMENT OF DEFENSE STANDARDS MIL-STD-108 - Definitions of and Basic Requirements for Enclosures for Electric and Electronic Equipment MIL-STD-130 - Identification Marking of U.S.

10、Military Property DEPARTMENT OF DEFENSE HANDBOOK MIL-HDBK-454 - General Guidelines for Electronic Equipment (Copies of these documents are available online at https:/assist.daps.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2

11、.3 Non-government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Provided by IHSNot for ResaleNo reproduction or networking permitted without

12、 license from IHS-,-,-MIL-DTL-52286D 3 AMERICAN SOCIETY FOR QUALITY (ASQ) ASQ Z1.4 - Sampling Procedures and Tables for Inspection by Attributes (Copies of this document are available from http:/www.asq.org/ or American Society of Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203.) ASTM INTE

13、RNATIONAL ASTM A466/A466M - Standard Specification for Weldless Chain ASTM B26/B26M - Standard Specification for Aluminum-Alloy Sand Castings ASTM B633 - Standard Specification for Electrodeposited Coatings of Zinc on Iron and Steel ASTM D2240 - Standard Test Method for Rubber Property -Durometer Ha

14、rdness (Copies of these documents are available online at http:/www.astm.org/ or from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959.) MASTER PAINTERS INSTITUTE (MPI) Reference Number 8 - Alkyd, Exterior Flat (MPI Gloss Level 1) Reference Number 9 - Alkyd,

15、 Exterior Gloss (MPI Gloss Level 6) Reference Number 47 - Alkyd, Interior, Semi-Gloss (MPI Gloss Level 5) Reference Number 48 - Alkyd, Interior, Gloss (MPI Gloss Level 6) Reference Number 49 - Alkyd, Interior, Flat (MPI Gloss Level 1) Reference Number 51 - Alkyd, Interior, (MPI Gloss Level 3) Refere

16、nce Number 94 - Alkyd, Exterior, Semi-Gloss (MPI Gloss Level 5) (Copies of these documents are available from http:/ or from Master Painters Institute, 2800 Ingleton Ave., Burnaby, BC V5C 6G7, Canada. SAE INTERNATIONAL SAE AS7928 - Terminals, Lug: Splices, Conductor: Crimp Style, Copper, General Spe

17、cification for (Copies of this document are available from http:/www.sae.org/ or from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-52286D 4 SOCIETY FOR PROTECTIVE COATI

18、NGS SSPC-Paint 25 - Zinc Oxide, Alkyd, Linseed Oil Primer for Use Over Hand Cleaned Steel Type I and Type II (Copies of this document are available from http:/www.sspc.org/ or from The Society for Protective Coatings, 40 24th Street, 6th Floor, Pittsburgh, PA 15222-4656.) UNDERWRITERS LABORATORIES U

19、L 496 - Lampholders (Copies of these documents are available from http:/ or from Underwriter Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and

20、the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The individual ite

21、m requirements shall be as specified herein and in accordance with the applicable specification sheet. In the event of any conflict between the requirements of this specification and the specification sheet, the latter shall govern. 3.2 Description. Cable assemblies shall consist of cables, connecto

22、rs, dummy connectors, adapters, and terminal lugs and shall be as shown on figures 1 through 46 and applicable specification sheets. Dimensions and tolerances are shown where required. Where tolerances are not shown or where those prescribed could result in incorrect fits, the contractor is responsi

23、ble for providing tolerances to insure correct fit, assembly, and operation of each assembly. No deviation from dimensions or tolerances shown on the figures is permissible without prior approval of the contracting officer. 3.3 First article. When specified (see 6.2), a sample shall be subjected to

24、first article inspection in accordance with 4.2. 3.3.1 First article sample. The contractor shall furnish two cable assemblies of each type supplied for examination and test within the time frame specified (see 6.2) to prove prior to starting production that his production methods and choice of desi

25、gn detail will produce cable assemblies that comply with the requirements of this specification. Examination and tests shall be as specified in section 4; and, unless otherwise specified herein, all examinations and tests shall be conducted by the contractor subject to surveillance and approval by t

26、he Government (see 6.3). When specified (see 6.2), the Government will conduct any or all of the first article examination and tests (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-52286D 5 3.4 Operation. Each cable assembly, when

27、connected to a source of power and carrying rated current shall not overheat or show signs of arcing. The connectors or terminals shall show no signs of electrical or mechanical malfunction or damage when connected or disconnected. 3.5 Cable. The cable shall be of the low-temperature, heat-resistant

28、 kind, conforming to MIL-DTL-3432 and shall be of the type and length specified on the applicable specification sheet. 3.6 Molded connectors (plugs, receptacles, inserts, adapters, and dummy connectors). Material used for insulation and jacketing shall be the same as the cable to which the connector

29、s are to be vulcanized and shall have a durometer type A hardness of 60 10 as described in ASTM D2240. The insulation shall fully enclose the base of the pins and sockets. The jacket shall be molded integrally to the insulation. The connector shall be vulcanized to the cable and shall form a waterti

30、ght seal as defined in MIL-STD-108. 3.7 Metal connector with molded insert. 3.7.1 Shell and cover. Connector shells and covers for molded inserts shall be of cast aluminum conforming to ASTM B26/B26M, alloy 356, temper T6. Pins and nuts used to secure the covers shall be of carbon steel. 3.7.2 Remov

31、ability of inserts. All molded inserts for connectors shall be removable. Provisions shall be made to position inserts to prevent rotation with respect to the shell. 3.8 Dummy connectors. Dummy connectors shall be molded from insulation material conforming to MIL-I-3930 and as specified on the appli

32、cable figure. Dummy connectors shall prevent the entrance of moisture, dirt, or other foreign material into the specified plug. 3.8.1 Attaching means. Dummies shall be attached to the cable by either a length of cotton twine or a brass chain as specified on the applicable specification sheet. 3.8.1.

33、1 Cotton twine. Cotton twine shall conform to A-A-2917, Size No. 18, and shall be attached to the dummy and cable assembly by means of a durable knot which will not slip when pulled. 3.8.1.2 Chain. Chain shall conform to ASTM A466/A466M, plumbers chain (class SF), trade size 1/0; nominal metal thick

34、ness 0.023 inch; approximately 24 links per foot; and minimum breaking force of 110 pounds. 3.9 Connector adapters. Connector adapters shall consist of plugs and receptacles molded together to form a single piece. The material used for insulation shall be IS-L and jacketing shall be JS-L in accordan

35、ce with MIL-I-3930. The insulation shall fully enclose the base of the pins and sockets. The jacket shall be molded integrally to the insulation. Three-way adapters shall be furnished with two dummy connectors; five-way adapters shall be furnished with four dummy connectors. Provided by IHSNot for R

36、esaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-52286D 6 3.10 Caps. A watertight cap shall be placed on each single-conductor plug and each single-conductor receptacle for protection during shipment and installation. The cap shall consist of a rubber plug or recepta

37、cle made of jacket material conforming to MIL-I-3930 and shall be designed to protect the mating surfaces of the connector from moisture and dirt. Tape shall be wrapped over the joining seam to hold the cap securely in place and to give additional protection from moisture and dirt. The tape shall co

38、nform to MIL-I-24391 and shall be 0.0085 0.001 inch thick and 0.75 inch wide. The cap shall not damage or deform the connector in any way. 3.11 Pins and sockets. Pins and sockets of the molded connectors, inserts, and adapters shall be centered, anchored, and molded perpendicular to the face of the

39、component so that they will not loosen by repeated connection and disconnection with other electrical connectors. There shall be no intrusion of insulation or foreign material into the socket. Contact dimensions shall be as specified in table I. The illustrations shown on figure 1 are for dimensiona

40、l purposes only and are not intended to indicate the design. Applicable type numbers of contacts shall be as specified on the applicable figure. 3.11.1 Pins. The entering end of the pin shall be hemispherical with a radius of approximately one-half of the pin diameter. 3.11.2 Sockets. The receiving

41、end of the socket shall be rounded or chamfered for directing and centering the entering pin. Sockets shall have three slots 0.02 inch maximum width and approximately 120 degrees apart and shall have circumferential-type retaining springs for maintaining positive electrical contact between pin and s

42、ocket. Sockets shall have an external metallic retaining sleeve or band to prevent distortion of the socket. 3.11.3 Wire connections. Each conductor shall be mechanically and electrically bonded to the pin or socket. Each shall be closed at the end connected to the conductor to prevent moisture from

43、 entering the cable. 3.11.3.1 Strain relief. The conductors within the connector shall be arranged with adequate slack to prevent the conductors from breaking, or separating from pins or sockets, when subjected to jerks or pulls on the cable. 3.12 Bond between connectors and cables. The bond between

44、 a connector or insert and a cable shall withstand the pull specified on the applicable specification sheet for 1 minute without mechanical or electrical damage. 3.13 Degree of closure. Molded connectors, adapters, inserts, caps, and dummy connectors when mated with applicable mating components shal

45、l provide a watertight joint as defined in MIL-STD-108. 3.14 Connect and disconnect force. Connect and disconnect force of the connectors shall be as shown on the applicable figure and connectors shall be constructed to withstand 500 repeated connections and disconnections without damage. Provided b

46、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-52286D 7 TABLE I. Contact dimensions. Pin Socket A B C D TYPE (inch) (inch) (inch) (inch) max. 0.656 0.156 0.703 0.158 I min. 0.594 0.154 0.641 0.156 max. 1.109 0.187 1.172 0.189 II S min. 1.031 0.185 1.0

47、94 0.187 max. 1.109 0.250 1.172 0.252 II P min. 1.031 0.248 1.094 0.250 max. 1.250 0.312 1.312 0.314 III S1min. 1.125 0.310 1.188 0.312 max. 1.250 0.375 1.312 0.377 III P2min. 1.125 0.373 1.188 0.375 max. 1.641 0.375 1.750 0.377 IV S min. 1.562 0.486 1.625 0.375 max. 1.641 0.438 1.750 0.440 IV P min

48、. 1.562 0.436 1.625 0.438 max. 1.077 0.187 1.125 0.189 V min. 1.015 0.185 1.062 0.187 max. 0.828 0.156 0.891 0.158 VI S min. 0.750 0.154 0.859 0.156 max. 0.828 0.218 0.891 0.220 VI P min. 0.750 0.216 0.859 0.218 max. 0.515 0.125 0.562 0.127 VII S min. 0.453 0.123 0.500 0.125 max. 0.515 0.156 0.562 0

49、.158 VII P min. 0.453 0.154 0.500 0.156 max. 0.490 0.125 - - VIII S min. 0.360 0.123 - - max. 0.490 0.156 - - VIII P min. 0.360 0.154 - - max. 1.703 0.312 1.781 0.314 IX min. 1.601 0.310 1.703 0.312 max. 0.640 0.125 0.703 0.127 X S min. 0.610 0.123 0.641 0.125 max. 0.640 0.156 0.703 0.158 X P min. 0.610 0.154 0.641 0.156 max. 2.250 0.625 2.312 0.627 XI min. 2.187 0.623 2.250 0

展开阅读全文
相关资源
猜你喜欢
  • ASTM C1103M-2014 Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines (Metric)《已安装的预制混凝土污水管线 (米制) 接头验收试验的标准实践规程》.pdf ASTM C1103M-2014 Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines (Metric)《已安装的预制混凝土污水管线 (米制) 接头验收试验的标准实践规程》.pdf
  • ASTM C1104 C1104M-2000(2006) Standard Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation《测定未覆面矿物纤维绝缘材料的水蒸汽吸收性的标准试验方法》.pdf ASTM C1104 C1104M-2000(2006) Standard Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation《测定未覆面矿物纤维绝缘材料的水蒸汽吸收性的标准试验方法》.pdf
  • ASTM C1104 C1104M-2013 Standard Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation《测定未覆面矿物纤维绝缘材料的水蒸汽吸收性的标准试验方法》.pdf ASTM C1104 C1104M-2013 Standard Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation《测定未覆面矿物纤维绝缘材料的水蒸汽吸收性的标准试验方法》.pdf
  • ASTM C1104 C1104M-2013a Standard Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation《测定未覆面矿物纤维绝缘材料水蒸汽吸收性的标准试验方法》.pdf ASTM C1104 C1104M-2013a Standard Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation《测定未覆面矿物纤维绝缘材料水蒸汽吸收性的标准试验方法》.pdf
  • ASTM C1105-2005 Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction《由于碱金属碳酸盐矿石反应引起混凝土长度变化的标准试验方法》.pdf ASTM C1105-2005 Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction《由于碱金属碳酸盐矿石反应引起混凝土长度变化的标准试验方法》.pdf
  • ASTM C1105-2008 Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction.pdf ASTM C1105-2008 Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction.pdf
  • ASTM C1105-2008a Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction《由于碱金属碳酸盐矿石反应引起混凝土长度变化的标准试验方法》.pdf ASTM C1105-2008a Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction《由于碱金属碳酸盐矿石反应引起混凝土长度变化的标准试验方法》.pdf
  • ASTM C1105-2008a(2016) Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction《由于碱金属碳酸盐矿石反应引起混凝土长度变化的标准试验方法》.pdf ASTM C1105-2008a(2016) Standard Test Method for Length Change of Concrete Due to Alkali-Carbonate Rock Reaction《由于碱金属碳酸盐矿石反应引起混凝土长度变化的标准试验方法》.pdf
  • ASTM C1106-2000(2005) Standard Test Methods for Chemical Resistance and Physical Properties of Carbon Brick《碳砖物理特性及耐化学性的标准试验方法》.pdf ASTM C1106-2000(2005) Standard Test Methods for Chemical Resistance and Physical Properties of Carbon Brick《碳砖物理特性及耐化学性的标准试验方法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1