1、AMSC N/A FSC 5930 INCH-POUND MIL-DTL-5423/17 18 February 2010 DETAIL SPECIFICATION SHEET BOOT, DUST AND WATER SEAL, BUSHING SEAL, TYPE A STYLE 10 (PANEL BUSHING SEAL ONLY) This specification sheet is approved for use by all Departments and Agencies of the Department of Defense. The requirements for
2、acquiring the product described herein shall consist of this specification sheet and MIL-DTL-5423. FIGURE 1. Dimensions and configuration boots type A, style 10. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5423/17 2 NOTES: 1. Dimensions a
3、re in inches. 2. Metric equivalents are given for general information only. 3. This seal is intended for use with toggle switches per MIL-DTL-3950, MIL-DTL-8834, and MIL-DTL-83731. 4. Bushing seal to be assembled so that surface marked “Top” is up, or “Bottom” is down. FIGURE 1. Dimensions and confi
4、guration boots type A, style 10 Continued. Inches mm Inches mm A 0.110 +.010 0.28+0.03 F .610+.015 1.55 +0.04 -.005 -0.0127 -.015 -0.04 B .086 0.22G .0620.16 C .062 0.015 0.16+0.04 H .0150.04 -.013 -0.033 D .466 +.006 1.18+0.02 J .078+.005 0.20 +0.01 -.005 -0.01 -.006 -0.02 E .426 +.006 1.08+0.02 K
5、.0150.04 -.006 -0.02 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-5423/17 3 REQUIREMENTS Dimensions and configuration: See figure 1. Silicon rubber: Grade 50. Qualification: First Article Testing in accordance with MIL-DTL-5423. Watertight
6、ness: The boot (bushing seal) shall be assembled to the test enclosure using a solid bushing of dimensions equivalent to a bushing of an applicable switch (including the non-turn notch). The solid bushing and bushing seal shall be assembled per figure I. The test shall be conducted in accordance wit
7、h the “Final” watertightness test of MIL-DTL-5423, except that the pressure shall be limited to 6 pounds-force per square inch gauge, external pressure only, and no operations are required. At the conclusion of this procedure, the test enclosure shall be examined in the bushing area for evidence of
8、water leakage. The following tests are not required: Restoring force, durability, sand and dust, vibration, salt spray, endurance and lubricant. Part or Identifying Number (PIN): M5423/17-01 Reference Documents: MIL-DTL-5423 MIL-DTL-3950 MIL-DTL-8834 MIL-DTL-83731 Custodians: Preparing activity: Arm
9、y - CR DLA - CC Navy - AS Air Force - 85 (Project 5930-2010-012) DLA - CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-