DLA MIL-DTL-55021 1 D-2011 CABLE ELECTRICAL SHIELDED SINGLES SHIELDED AND JACKETED SINGLES TWISTED PAIRS AND TRIPLES INTERNAL HOOKUP -40 TO 105 Degrees C.pdf

上传人:tireattitude366 文档编号:690964 上传时间:2018-12-30 格式:PDF 页数:3 大小:42.65KB
下载 相关 举报
DLA MIL-DTL-55021 1 D-2011 CABLE ELECTRICAL SHIELDED SINGLES SHIELDED AND JACKETED SINGLES TWISTED PAIRS AND TRIPLES INTERNAL HOOKUP -40 TO 105 Degrees C.pdf_第1页
第1页 / 共3页
DLA MIL-DTL-55021 1 D-2011 CABLE ELECTRICAL SHIELDED SINGLES SHIELDED AND JACKETED SINGLES TWISTED PAIRS AND TRIPLES INTERNAL HOOKUP -40 TO 105 Degrees C.pdf_第2页
第2页 / 共3页
DLA MIL-DTL-55021 1 D-2011 CABLE ELECTRICAL SHIELDED SINGLES SHIELDED AND JACKETED SINGLES TWISTED PAIRS AND TRIPLES INTERNAL HOOKUP -40 TO 105 Degrees C.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A FSC 6145 INCH-POUND MIL-DTL-55021/1D SUPERSEDING 23 March 2011 MIL-DTL-55021/1C 11 August 2000 DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, SHIELDED SINGLES, SHIELDED AND JACKETED SINGLES, TWISTED PAIRS AND TRIPLES, INTERNAL HOOKUP, -40 TO 105 oC This specification is approved for use by

2、all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-55021. REQUIREMENTS. Cable construction: The cable shall consist of shielded singles, shielded and jacketed singles, or twisted

3、 pairs or triples in accordance with MIL-DTL-55021 (see figure 1 herein). FIGURE 1. Shielded and jacketed cable. Type of wire(s): The insulated wires used in constructing the cable shall conform to MIL-DTL-16878/1 (type B), MIL-DTL-16878/2 (type C), MIL-DTL-16878/3 (type D), MIL-DTL-16878/17 (type B

4、J), MIL-DTL-16878/18 (type CJ), or MIL-DTL-16878/19 (type DJ) as specified (see MIL-DTL-55021). All wires in the cable shall be of the same wire type and AWG size. Length of lay: The length of lay shall be as specified in table I. Shield coverage and braid angle: If shielding is required by the cont

5、ract or order (see MIL-DTL-55021), the minimum allowable coverage shall be 90 percent, and the angle made by the shielding braid with the longitudinal axis of the twisted conductors shall be between 20 and 40 degrees. Provided by IHSNot for ResaleNo reproduction or networking permitted without licen

6、se from IHS-,-,-MIL-DTL-55021/1D 2 TABLE I. Length of layWire size range . (AWG) Inches per twist Twist tolerance (inch) 32 to 24 2.0 .5 22 to 18 2.5 .5 16 to 14 3.5 .5 12 to 10 4.5 .5 8 to 6 5.5 .5 4 to 1/0 6.0 .5 Jacket materials: If jacketing is required by the contract or order (see MIL-DTL-5502

7、1), the jacket materials shall be polyvinyl chloride or polyamide. Jacket wall thickness: The jacket wall thickness shall be specified in table II or table III. When a polyamide jacket of greater than .250 inches is specified, a polyamide braid conforming to MIL-C-572 shall be used. TABLE II. Polyvi

8、nyl chloride jacket thicknessDiameter over braided shield 1/. (inch) Jacket thickness (nominal) (inch) Jacket thickness (minimum) (inch) Under .375 .016 .008 .375 and over .025 .015 1/ When specifying a jacket thickness, both unshielded and shielded constructions are applicable. TABLE III. Polyamide

9、 jacket thicknessDiameter over braided shield 1/. (inch) Jacket thickness (nominal) (inch) Jacket thickness (minimum) (inch) Under .200 .006 .004 .200 and over .008 .006 1/ When specifying a jacket thickness, both unshielded and shielded constructions are applicable. Heat resistance: The cable shall

10、 be conditioned at 1055 oC for 96+1, -0 hours. Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issues due to the extensiveness of the changes. Referenced documents. In addition to MIL-DTL-55021, this document references t

11、he following: MIL-C-572 MIL-DTL-16878/1 MIL-DTL-16878/2 MIL-DTL-16878/3 MIL-DTL-16878/17 MIL-DTL-16878/18 MIL-DTL-16878/19 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-55021/1D 3 CONCLUDING MATERIAL Custodians: Preparing activity: Army - M

12、I DLA - CC Navy - AS Air Force 85 (Project 6145-2011-011) DLA - CC Review activities: Army - AR, AT, CR, CR4 Note: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information using the Assist Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1