1、MIL-DTL-62011/2 27 July 2009 DETAIL SPECIFICATION SHEET PUMP, FUEL, ELECTRICALLY-OPERATED: 24-VOLT DC, IN-TANK TYPE, SIDE-MOUNTED CONNECTOR, TYPE II This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product describ
2、ed herein shall consist of this specification sheet and MIL-DTL-62011. FIGURE 1. Fuel pump, side-mounted, envelope dimensions. ASMC N/A FSC 2910 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62011/2 2 Inches mm Inches mm .13 3.3
3、2.00 50.8 .17 4.3 2.5 64.0 .19 4.8 2.95 74.9 .25 6.4 3.0 76.0 .38 9.7 3.78 96.0 .4375 11.113 3.82 97.0 .50 12.7 4.17 105.9 .69 17.5 4.50 114.3 .90 22.9 6.56 166.6 8.00 203.2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. FIGURE 1. Fuel pump, side-mounted, e
4、nvelope dimensions Continued. REQUIREMENTS Dimensions and configuration: See figure 1. Pump: The pump shall be an electrically-operated 27.5-volt dc in-tank type pump conforming to the envelope dimensions on figure 1. The pump shall be designed to be mounted vertically within a fuel tank. The pump c
5、over shall be secured to the pump assembly using positive means (e.g., rivets, staked pins, or screws) at a minimum of two places (see figure 1). The specific method and location is optional. The inlet area of the pump shall be covered by a screen of either wire fabric industrial grade monel or stai
6、nless steel 18 x 18 mesh with 0.017-inch (.43 mm) diameter wire (see figure 1). Cable: The pump shall be provided with a top-mounted connector. The electric cable connection shall be mounted to the cylindrical surface of the motor housing and perpendicular to the longitudinal axis of the pump. A fle
7、xible shielded cable, as defined on figure 1, of a specified length may be provided. The cable shall incorporate a grounding connection for the shielding braid. An independent ground connection shall be used. Finish. Finishes shall be as specified in table I. All platings shall be capable of meeting
8、 a minimum of 100 hours salt spray test in accordance with MIL-DTL-62011. The fittings shall show no evidence of corrosion after 100 hours of salt spray. Fluid passages, other openings and internal threads shall not be subject to the plating thickness requirement and may have bare areas provided the
9、y are protected with a light film of oil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62011/2 3 TABLE I. Material and finish identification codes. PIN code material/plating finish Plating Finish Blank Cadmium plating in accordance with SA
10、E-AMS-C-81562, type II, class 3 or SAE-AMS-QQ-P-416, type II, class 2. H Aluminum-nickel in accordance with ASTM F1136, grade 3, NC. J Zinc-nickel in accordance with SAE-AMS2417, type 1. N Nickel in accordance with SAE-AMS-QQ-N-290, class 2, grade B P Zinc phosphate finish in accordance MIL-DTL-1623
11、2 type Z, class1. R Zinc plating in accordance with ASTM B633; type VI, Fe/Zn 5. 1/ Z Zinc plating in accordance with ASTM B633; type II or III, Fe/Zn 5, or ASTM B695, type II, class 5. 1/ Hexavalent chromium free. The Part or Identifying Number (PIN) consists of the letters M, the basic specificati
12、on number, specification sheet number, a dash, the cable length, and finish. PIN example: M62011/2-008-H Referenced documents. In addition to MIL-DTL-62011, this document references the following: MIL-DTL-16232 ASTM B633 ASTM B695 ASTM F1136 SAE-AMS2417 SAE-AMS-QQ-P-416 SAE-AMS-C-81562 SAE-AMS-QQ-N-
13、290 Specification number Specification sheet number Cable length (inches) M 60211 /2 - 000 - H M prefix Finish (see table I) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-62011/2 4 CONCLUDING MATERIAL Custodians: Preparing activity: Army -
14、AT DLA - CC Navy - AS Air Force 99 (Project 2910-2009-005) DLA - CC Review activities: Navy - MC Air Force 70, 71 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-