DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf

上传人:李朗 文档编号:691071 上传时间:2018-12-30 格式:PDF 页数:12 大小:130.38KB
下载 相关 举报
DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf_第1页
第1页 / 共12页
DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf_第2页
第2页 / 共12页
DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf_第3页
第3页 / 共12页
DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf_第4页
第4页 / 共12页
DLA MIL-DTL-7601 C-2011 GAGE EMERGENCY OXYGEN TYPE L-2.pdf_第5页
第5页 / 共12页
点击查看更多>>
资源描述

1、Comments, suggestions, or questions on this document should be addressed to DLA Aviation VEB, 8000 Jefferson Davis Highway, Richmond, VA 23297-5616, or e-mailed to STDZNMGTdla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST

2、database at https:/assist.daps.dla.mil/. AMSC N/A FSC 6685 INCH-POUND MIL-DTL-7601C 17 October 2011 SUPERSEDING MIL-G-7601B 15 November 1982 DETAIL SPECIFICATION GAGE, EMERGENCY OXYGEN, TYPE L-2 Reactivated after 17 October 2011 and may be used for new and existing designs and acquisitions. This spe

3、cification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type of high-pressure, emergency oxygen gage, range 0 to 2,500 pounds-force per square inch gauge (psig), designated type L-2. 2. APPLICABLE DOCUMENTS 2.1 Ge

4、neral. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the complete

5、ness of this list, document users are cautioned that they must meet all specified requirements of the documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications and standards. The following specifications and standards fo

6、rm a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 2 FEDERAL STANDARD FED

7、-STD-595/31136 - Red, Flat or Lusterless COMMERCIAL ITEM DESCRIPTION A-A-59503 - Nitrogen, Technical DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-27210 - Oxygen, Aviators Breathing, Liquid and Gas DEPARTMENT OF DEFENSE STANDARDS MIL-STD-130 - Identification Marking of U.S. Military Property MIL-STD-

8、889 - Dissimilar Metals MIL-STD-31000 - Technical Data Packages (Copies of these documents are available online at https:/assist.daps.dla.mil/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-government publications. The followin

9、g documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. ASTM INTERNATIONAL ASTM B545 - Standard Specification for Electrodeposited Coatings of Tin (Copies of this document are

10、available online at http:/www.astm.org/ or from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959.) SAE INTERNATIONAL SAE AS71051 - Pipe Threads, Taper, Aeronautical National Form, Symbol ANPT - Design and Inspection Standard SAE AS8879 - Screw Threads - UNJ

11、Profile, Inch Controlled Radius Root with Increased Minor Diameter SAE AS5201 - Fitting End, External Taper Pipe Thread, Design Standard (Copies of these documents are available online at http:/www.sae.org or from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) Provided by IHS

12、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 3 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes

13、precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article inspection. When specified (see 6.2), sample gages shall be subjected to first article inspection in accordance with 4.3. 3.2 Mat

14、erials. 3.2.1 Nonferrous materials. Unless otherwise specified, nonferrous materials shall be used for all parts of the gage except where ferrous materials are essential. Ferrous materials, when used, shall not come in direct contact with oxygen. 3.2.1.1 Dissimilar materials. Unless suitably protect

15、ed against electrolytic corrosion, dissimilar metals shall not be used in intimate contact with each other. Dissimilar metals are defined in MIL-STD-889. 3.2.2 Nonmetallic materials. Any nonmetallic material that is easily deteriorated or otherwise easily affected adversely by continued service use

16、with oxygen shall not be used. 3.2.3 Protective treatment. When materials are used in the construction of the gage that are subject to corrosion in oxygen, salt air, or other atmospheric conditions likely to occur during service usage, they shall be protected against such corrosion in a manner that

17、will in no way prevent compliance with the performance requirements of this specification. The use of any protective coatings and finishes that will crack, chip, or scale with normal service life, age, or extremes of atmospheric conditions shall not be used. 3.2.4 Recycled, recovered, or environment

18、ally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.3 Design. The ga

19、ge shall be designed to conform to figure 1. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 4 NOTES: 1. All dimensions are shown in inches. 2. Unless otherwise specified, all tolerances shall be 0.016. 3. Dial text and numerical markin

20、gs shall be not less than 0.062 in height. 4. 1/8ANPT fitting shall be tinned in accordance with ASTM B545. 5. The left-most end of the dial range (below 1800), the “REFILL“, and the “USE NO OIL“ markings shall be colored a flat, lusterless red to conform with FED-STD-595/31136. 6. All other dial ma

21、rkings and the pointer shall be colored flat black. 7. The left edge of the pointer shall be considered the indicating edge. 8. The dial face shall have a white background. FIGURE 1. Gage, emergency oxygen, type L-2. 3.4 Construction. The gage shall be so constructed that no parts will work loose in

22、 service. The mechanism shall be built to withstand without failure, the strains, jars, vibration, and other conditions incident to shipping, storage, installation, and service. Pivots, bearings, and gears, shall neither bind nor shake, and shall be as near frictionless as practicable. The gages sha

23、ll be so constructed that minor repairs such as replacement of cover glasses and pointers can be easily made by the personnel of the operating units without the use of special tools. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 5 3.4

24、.1 Hair springs. If hair springs are used in the construction of the gage, they shall be made of beryllium copper or phosphor bronze. 3.4.2 Bourdon tube. The bourdon tube shall be constructed of beryllium copper. 3.4.3 Viewing window. The viewing window shall be constructed of transparent plastic ma

25、terials, clear, flat, and free from flaws which will affect the readability of the gage. The plastic material shall not craze and shall remain transparent when subjected to the temperatures specified herein. 3.4.4 Case. 3.4.4.1 Base. The base of the case shall be fabricated from brass or other suita

26、ble metal. 3.4.4.2 Cover. The cover of the case shall be fabricated from steel or other materials of suitable strength to withstand the normal service conditions. Materials such as soft aluminum which are subject to damage under service conditions shall not be used. 3.4.5 Protective cap. The externa

27、l thread fitting conforming to SAE AS5201 shall be fitted with a suitable cap to protect the threads and to prevent dust and foreign matter from entering the gage during shipping and storage. 3.4.6 Pointer. The pointer shall be of sufficient length that the top end will extend not less than half of

28、the distance into the dial arc marking. The pointer shall be dull black in color. The pointer shall be 0.020 0.005 inch wide at the point where it crosses the lower scale arc. The pointer shall be as light as practicable and sufficiently rigid to prevent oscillation under vibration. 3.4.6.1 Pointer

29、adjustments. A mechanical high limit stop, if used, shall be applied to the mechanism and not to the pointer. The pointer shall be firmly attached to the mechanism, yet shall be readily adjustable. 3.4.7 Dial. The dial shall be securely fastened upon the frame assembly to insure that it will not bec

30、ome loose or turn when the gage is subjected to vibration. 3.4.8 Dial to viewing window distance. The distance between the dial and the inside of the viewing window shall be the minimum practicable, but shall be sufficient to insure freedom of movement of the pointer under all conditions of gage ope

31、ration. 3.4.9 Mechanism adjustment. The mechanism shall be provided with a means to adjust the gage indication, as necessary, during the service life of the gage. The means of adjustment shall be reasonably simple to manipulate, and shall be of such a nature that adjustment can be accomplished witho

32、ut the use of special tools. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 6 3.4.10 External construction. The indicating and pressure elements shall comprise a sub-unit distinct from the case. The gage external construction, to inclu

33、de the case, the base, and the threaded fitting, shall be sufficiently rugged to insure that small distortions of the case will not have undue effect on the internal sub-unit, thereby affecting the accuracy of the gage indication. 3.5 Interchangeability. All parts having the same manufacturers part

34、number shall be directly and completely interchangeable with each other with respect to installation and performance. Changes in manufacturers part number shall be governed by the technical data requirements of MIL-STD-31000. 3.6 Weight. The weight of the gage shall not exceed 0.16 pound. 3.7 Thread

35、s. 3.7.1 Screw. Machine screw threads shall be in accordance with SAE AS8879. 3.7.2 Pipe. ANPT pipe threads shall be in accordance with SAE AS71051. Threads shall be tinned in accordance with ASTM B545. 3.7.2.1 Pipe thread lubrication. Unless otherwise specified (see 6.2), the pipe thread shall be f

36、ree of lubrication. 3.8 Filter. The inlet shall be provided with a sintered bronze porous plug to prevent foreign materials from entering the gage. 3.9 Performance. 3.9.1 Leakage. 3.9.1.1 Bourdon tube. The bourdon tube and base, upon completion of the assembly, shall be capable of withstanding a gas

37、 pressure of 2,000 psig without leakage while immersed in a water bath. 3.9.1.2 Case. The case shall be mechanically tight in all joints. 3.9.2 Scale error. A master gage of known accuracy shall indicate at least 1,800 psig, but not more than 1,900 psig, when the gage being tested indicates 1,800 ps

38、ig. 3.9.3 Friction. The pointer shall not move more than the width of the black indication marker (see figure 1) when a pressure of 1,800 psig is applied and the gage is tapped lightly. The pointer shall move smoothly throughout the complete deflection range without vibration. 3.9.4 Drift. The point

39、er of the gage shall not move out of the width of the black indication marker (see figure 1) at 1,800 pounds after being subjected to 1,800 psig pressure for 1 hour. The gage shall be lightly tapped during this test. Provided by IHSNot for ResaleNo reproduction or networking permitted without licens

40、e from IHS-,-,-MIL-DTL-7601C 7 3.9.5 Seasoning. The gage shall be capable of satisfactory operation after being subjected to a pressure of 1,800 psig for not less than 300 cycles. 3.9.6 Temperature. 3.9.6.1 Low temperature. The gage shall demonstrate proper function at a temperature of -65 F (-54 C)

41、. 3.9.6.2 High temperature. The gage shall demonstrate proper function at a temperature of 160 F (71 C). 3.9.7 Overpressure. The gage shall not leak or burst while being subjected to a hydrostatic pressure of 3,500 psig for not less than 5 minutes. 3.9.8 Vibration. The gage shall function satisfacto

42、rily after being vibrated at any desired frequency between 500 and 2,500 cycles per minute (cpm) with a double-amplitude of not less than 0.018 inch, nor more than 0.020 inch, for a period of not less than 3 hours. 3.10 Markings. 3.10.1 Dial markings. The dial shall have a white background with dull

43、 black markings, unless otherwise specified (see 6.2). It shall be marked with an arc 0.031 inch wide showing the pressure range of the gage. A black indication marker, consisting of a segment of a width corresponding to a 100-psig segment of the scale arc plus the width of the pointer at the scale

44、arc, shall be placed at the point corresponding to the 1,800 psig pressure indication on the arc. This marker shall be set normal to the upper scale arc surface. True 1,800-psig pressure shall be indicated on the gage by the left-most edge of the pointer lining up with the left-most edge of the 1,80

45、0-psig indicator marking. A marking of “1800“ (less quotes) shall be plainly marked in proximity to the 1,800-psig pressure indication marker on the dial. 3.10.1.1 Up-pressure side. The remainder of the indicator scale on the up-pressure side shall be marked in black and continue to the 2,500-pound

46、pressure limit. A marking of “2500“ (less quotes) shall be plainly marked in proximity to the 2,500-psig pressure indication marker on the up-pressure limit end of the dial. 3.10.1.2 Indicator scale. Starting at the left edge of the 1,800-psig pressure indication marking, the indicator scale shall b

47、e continued to the zero-pressure limit in a lusterless red color, in accordance with shade number 31136 of FED-STD-595. The words “REFILL“ (less quotes) shall be in red, and “FULL“ in dull black and shall be located along the arc as shown in figure 1. The word “OXYGEN“ shall be marked on the dial in

48、 dull black. The “FULL“ and “REFILL“ markings may be located on the opposite side of the arc instead of being located as shown on figure 1. 3.10.1.3 Additional markings. The following marking in red letters shall be placed on the dial as shown on figure 1: “USE NO OIL“ (less quotes). Provided by IHS

49、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-7601C 8 3.10.1.4 Durability. All markings shall be sufficiently durable to withstand use encountered in normal service life. 3.11 Identification of product. Each gage shall be marked in accordance with MIL-STD-130, with the following information, using letters not less than 0.062 inch high:

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 标准规范 > 国际标准 > 其他

copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1