1、AMSC N/A FSC 5930 INCH-POUND MIL-DTL-9395/39D 1 March 2010 SUPERSEDING MIL-DTL-9395/39C 30 May 2001 DETAIL SPECIFICATION SHEET SWITCHES, PRESSURE, (GAUGE) TYPE II, LOW LEVEL TO 5 AMPERES This specification is approved for use by all Departments and Agencies of the Department of Defense. The complete

2、 requirements for acquiring the switches described herein shall consist of this specification and the latest issue of MIL-DTL-9395. Inches mm Inches mm.03 0.8 .55 14.0.035 0.89 .56 14.2.055 1.40 .750 19.05.125 3.18 .87 22.1.200 5.08 1.12 28.4.224 5.69 1.135 28.83.25 6.4 1.50 38.1.50 12.7 2.37 60.2NO

3、TES: 1. Dimensions are in inches. Metric equivalents are given for general information only. 2. Exact shape of switch optional provided dimensions specified are not exceeded and mounting holes and connector location are as specified. 3. Schematic shown is for switches with pressure ports exposed to

4、zero lbf/in2. 4. Unless otherwise specified, tolerances are .010 (0.25 mm) for three place decimals and .02 (.51 mm) for two place decimals. FIGURE 1. Switches. MIL-DTL-38999 SAE-AS4395E05 .200 DIA THRU .224 (2) PLACES Provided by IHSNot for ResaleNo reproduction or networking permitted without lice

5、nse from IHS-,-,-MIL-DTL-9395/39D 2 REQUIREMENTS: Dimensions, configuration, and electrical schematic: See figure 1. Weight: See figure 1. Calibration: See tables I, II, III, and IV. System pressure: 180 lbf/in2. Proof pressure: 270 lbf/in2. Burst pressure: 800 lbf/in2. Electrical ratings: See table

6、 I. Minimum current: 25,000 cycles. Low level: 50,000 cycles. NOTE: Switches shall be subjected only to low level loads prior to delivery. Seal: Electrical chamber: See table I. Pressure chamber: Hermetic. Reference chamber: Unsealed. Electrical connector: See figure 1. Pressure port: See figure 1.

7、Media: Dry air; nitrogen gas; fuel in accordance with MIL-DTL-5624; lubricating oil in accordance with MIL-PRF-7808; hydraulic fluid in accordance with MIL-PRF-5606 or MIL-PRF-83282; oxygen; or Coolanol 25R, or equal. High temperature (operating and nonoperating): B (275F). Low temperature (operatin

8、g and nonoperating): D (-65F). Altitude: C (except 80,000 feet). Shock: C (100 G). Vibration: S (test condition D, method 204 of MIL-STD-202, except 10 to 2,000 Hz, 20 G). Supplemental nonoperating sinusoidal vibration: Sweep time: 15 minutes. Frequency range and amplitude: 50 through 81 Hz, .036 in

9、ch double amplitude; 81 through 210 Hz, 12 G; 210 through 298 Hz, .0053 inch double amplitude; 298 through 50 Hz, 24G. Test duration: 15 minutes in each of three mutually perpendicular planes. Life (mechanical): A (100,000 cycles). Life (electrical): C (50, 000 cycles). Provided by IHSNot for Resale

10、No reproduction or networking permitted without license from IHS-,-,-MIL-DTL-9395/39D 3 Acceleration: C (8 G). Pulsation amplitude: A (0 percent). Pulsation frequency: A (0 Hz). Pressure rise: A (less than 100 lbf/in2). Dielectric withstanding voltage (at reduced barometric pressure): Applicable at

11、350 V rms. Electrical connector torque: 8 foot-pounds. Pressure port torque: 15 foot-pounds. Terminal strength: Applicable when terminals are used. Flame test: Applicable. Explosion: Applicable. QUALIFICATION: Single submission: Restricted to switch submitted. Group submission: See table V. QUALIFIC

12、ATION: Single submission: Restricted to switch submitted. Group submission: See table V. Part or Identifying Number (PIN): Consists of “M“ prefix followed by spec sheet number; a dash (-); and a five-letter code. The five-letter code identifies the configuration, electrical rating, and pressure sett

13、ing mode (code from table I); high-pressure setting (coarse value code from table II) followed by fine value with applicable tolerance (code from table III); and low-pressure setting (coarse value code from table II) followed by fine value with applicable tolerance (code from table III). The five-le

14、tter code used in the following example identifies a switch of configuration 1, low level to 1 ampere resistive at 28 V dc, which actuates on increasing pressure at 1.5 0.5 lbf/in2and deactuates on decreasing pressure at .5 0.5 lbf/in2. EXAMPLE: M9395/39- A A J “M“ prefix and specification sheet num

15、ber A G Configuration, electrical, rating, and pressure setting mode = code “A“ of table I High-pressure setting = code “A“ of table II (coarse value of 0 lbf/in2and code “J“ of table III (fine value of 1.5 0.5 lbf/in2). LOW-PRESSURE SETTING = Code “A“ of table II (coarse value of 0 lbf/in2and code

16、“G“ of table II (fine value of 0.5 0.5 lbf/in2). NOTE: Design limitations (actuation values and tolerances, deadband and actuation values and tolerances) should be coordinated with the manufacturer(s) listed on the QPL for this spec sheet before specifying a particular “M“ number. The fact that oper

17、ating characteristics can be coded does not necessarily mean that it can be manufactured or acquired. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-9395/39D 4 TABLE I. Codes for combinations of configurations, electrical ratings, and pressu

18、re settings modes. Low Level to 1 ampere resistive at 28 Vdc 1.5 to 5 amperes at 28 Vdc Pressure setting mode Configuration 1 Electrical chamber High pressure Low pressure Hermetic Unsealed Hermetic Unsealed Code A D G K At (or max) 1/ At (or min) 1/ Code B E H L At (or max) 1/ Differential 2/ Code

19、C F J M Differential 2/ At (or min) 1/ 1/ Setting values are designated by codes from table II and III. 2/ Setting values are designated by codes from table IV. TABLE II. Codes for coarse settings. Code Coarse value (lbf/in2) Code Coarse value (lbf/in2) Code Coarse value (lbf/in2) A 0 L 30 W 80 B 2.

20、5 M 35 X 85 C 5 N 40 Y 90 D 7.5 P 45 Z 95 E 10 Q 50 1 100 F 12.5 R 55 2 105 G 15 S 60 3 110 H 17.5 T 65 4 115 J 20 U 70 5 120 K 25 V 75 6 125 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-9395/39D 5 TABLE III. Codes for combinations of fine

21、 settings and tolerance values. Fine value (lbf/in2) for settings below 20 lbf/in2Tolerance (lbf/in2) 0 0.5 1 1.5 2 Code A B C D E 0.25 Code F G H J K 0.5 Code L M N P Q 1.0 Code R S T U V 1.5 Code W X Y Z 1 2.0 Code 2 3 4 5 6 2.5 Code 7 8 9 0 - 4/ Min or Max Fine value (lbf/in2) for settings of 20

22、lbf/in2 and above Tolerance (lbf/in2) 0 1 2 3 4 Code A B C D E 1.0 1/ Code F G H J K 2.0 2/ Code L M N P Q 3.0 3/ Code R S T U V 4.0 Code W X Y Z 1 5.0 Code 2 3 4 5 6 6.0 Code 7 8 9 0 - 4/ Min or Max 1/ Not applicable for pressure settings above 33 lbf/in2. 2/ Not applicable for pressure settings ab

23、ove 66 lbf/in2. 3/ Not applicable for pressure settings above 100 lbf/in2. 4/ A dash (-) is used as the code character for these fine setting and tolerance values. TABLE IV. Codes for differential settings. 1/ Code Differential value (lbf/in2) Code Differential value (lbf/in2) A 0 T 11 B 0.5 U 12 C

24、1 V 13 D 1.5 W 14 E 2 X 15 F 2.5 Y 16 G 3 Z 18 H 3.5 1 20 J 4 2 22 K 4.5 3 24 L 5 4 26 M 5.5 5 28 N 6 6 30 P 7 7 35 Q 8 8 40 R 9 9 45 S 10 0 50 1/ Differential settings require two codes, minimum differential and maximum differential. Provided by IHSNot for ResaleNo reproduction or networking permit

25、ted without license from IHS-,-,-MIL-DTL-9395/39D 6 TABLE V. Extent of qualification. PIN Number of samples required Tests Qualifies Electrical chambers either hermetically sealed or unsealed M9395/39-GAJAG 2 ea. resistive Complete in accordance with qualification inspection of MIL-DTL-9395 All -AAJ

26、AG 2 ea. intermediate current -A6R3W 2 ea. low level -G6R3W 2 ea. resistive Electrical chambers unsealed M9395/39-KAJAG 2 ea. resistive Complete in accordance with qualification inspection of MIL-DTL-9395 Configuration codes D, E, F, K, L, and M -DAJAG 2 ea. current -D6R3W 2 ea. low level -K6R3W 2 e

27、a. resistive The margins of this specification are marked with vertical lines to indicate where modifications were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate t

28、he requirements of this document based on the entire content irrespective of the marginal notations. Referenced documents: MIL-DTL-9395 MIL-PRF-5606 MIL-DTL-5624 MIL-PRF-7808 MIL-DTL-38999 MIL-PRF-83282 MIL-STD-202 Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project

29、5930-2008-046) DLA CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文