1、 MIL-HDBK-780D w/Change 1 6 January 2012 SUPERSEDING MIL-HDBK-780D 28 May 2004 DEPARTMENT OF DEFENSE HANDBOOK STANDARD MICROCIRCUIT DRAWINGS This handbook is for guidance only. Do not cite this document as a requirement. AMSC N/A FSC 5962 NOT MEASUREMENT SENSITIVE Provided by IHSNot for ResaleNo rep

2、roduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 ii FOREWORD 1. This handbook is approved for use by all Departments and Agencies of the Department of Defense. 2. This handbook provides guidance on standard microcircuit drawings (SMDs). The purpose of the SMD p

3、rogram is to minimize the proliferation of specification and source control drawings within the Department of Defense (DoD). The use of one SMD for an item of supply in use by DoD Departments and Agencies is the objective of this program. 3. It is intended that the issue of SMDs affect DoD procureme

4、nt through minimizing the proliferation of duplicate drawings for an item of supply. 4. It is also the objective of the SMD Program that the resulting drawing be multi-user in actual implementation. 5 The application of this handbook is currently confined to the acquisition of microcircuits until su

5、ch time that applicability to federal supply classes other than FSC 5962 is deemed appropriate. 6. Comments, suggestions, or questions on this document should be addressed to Commander, Defense Logistics Agency, DLA Land and Maritime, ATTN: VA, P. O. Box 3990, Columbus, OH 43218-3990 or emailed to S

6、TD1835dla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/. SUMMARY OF CHANGE 1 MODIFICATIONS 1. References to MIL-HDBK-512 has been changed to MIL-STD-3018, which supersedes it.

7、 2. References to MIL-STD-1835 and SD-19 have been added. 3. References to ASME Y14.5M has been changed to ASME Y14.5, which supersedes it. 4. The organization notated as ASME has been changed from American Society of Mechanical Engineers to ASME International to reflect the current name. 5. Section

8、 2, and throughout, the web address for acquiring government specifications and standards has been changed to the current address for the Assist online services. 6. Section 4.2.5.5, Classification of conformance inspections has been edited to include Group E which was missing. 7. In various location

9、s, Defense Supply Center Columbus has been changed to DLA Land Maritime to reflect the current name. 8. Figures 1-6 has been changed to reflect current boiler plates. 9. Where applicable, changes were made to comply with MIL-STD-967 for preparation of a military handbook. * * * * Provided by IHSNot

10、for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 iii CONTENTS PARAGRAPH PAGE 1. SCOPE 1 1.1 Scope 1 2. APPLICABLE DOCUMENTS 1 2.1 General . 1 2.2 Government documents 1 2.2.1 Specifications, standards, and handbooks 1 2.2.2 Other Government docu

11、ments, drawings, and publications 1 2.3 Non-Government publications . 1 2.4 Order of precedence . 2 3. DEFINITIONS . 2 3.1 Standard microcircuit drawing . 2 3.2 General specification . 2 3.3 Military Parts Control Advisory Group (MPCAG) . 2 4. GENERAL GUIDANCE . 2 4.1 Introduction . 2 4.2 Sectional

12、arrangement of an SMD 2 4.2.1 Subject matter . 2 4.2.2 Section 1 2 4.2.2.1 Scope . 2 4.2.2.2 Part or Identifying Number (PIN) . 2 4.2.3 Section 2 . 3 4.2.3.1 Listing of references 3 4.2.3.1.1 Government documents 3 4.2.3.1.2 Nongovernment standards and other publications 4 4.2.3.1.3 Order of precede

13、nce . 4 4.2.4 Section 3 . 4 4.2.4.1 Requirements 4 4.2.4.1.1 Organization of requirements 5 4.2.4.1.2 Sequencing of requirements and tests 5 4.2.4.2 Materials 5 4.2.4.3 Design . 5 4.2.4.4 Construction 5 4.2.4.5 Hardware . 5 4.2.4.6 Performance characteristics 5 4.2.4.7 Dimensions 6 4.2.4.8 Finish .

14、6 4.2.4.9 Marking . 6 4.2.4.10 Selection of alternative materials, construction, etc. 6 4.2.4.11 Certificate of compliance . 6 4.2.4.12 Certificate of conformance . 6 4.2.4.13 Notification of change or discontinuance . 6 * Provided by IHSNot for ResaleNo reproduction or networking permitted without

15、license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 iv CONTENTS PARAGRAPH PAGE 4.2.4.14 Verification and review 6 4.2.5 Section 4 . 6 4.2.5.1 Quality assurance provisions . 6 4.2.5.2 Responsibility for inspection 6 4.2.5.3 Responsibility for compliance 7 4.2.5.4 Conformance inspection 7 4.2.5.4.1 Conforma

16、nce inspection sampling . 7 4.2.5.5 Classification of conformance inspections . 7 4.2.5.6 Tabular listing of conformance inspection . 8 4.2.6 Section 5 . 8 4.2.6.1 Packaging, packing, and marking 8 4.2.7 Section 6 . 8 4.2.7.1 Notes . 8 4.2.7.2 Intended use 8 4.2.7.3 Comments . 8 4.2.7.4 Sources of s

17、upply 8 4.3 Approved SMDs 9 4.3.1 SMD user 9 4.3.2 Changes to SMDs 9 4.3.3 Nonconcurrence with proposed changes 9 5. DETAILED GUIDANCE . 9 5.1 Introduction 9 5.2 Drawing preparation 9 5.3 Initial drawing preparation . 9 5.3.1 Blank drawings 9 5.3.2 SMD coordination 9 5.3.3 Preliminary and final draf

18、t submittal . 9 5.3.3.1 Preliminary draft construction 9 5.3.4 Maintenance 9 5.3.5 SMD content preparation . 9 5.3.5.1 Section 1, scope 9 5.3.5.1.1 Scope 9 5.3.5.1.2 PIN 9 5.3.5.1.2.1 PIN length 10 5.3.5.1.3 Radiation hardness assurance (RHA) Designator . 10 5.3.5.1.4 Device type(s) . 10 5.3.5.1.5 D

19、evice class designator . 10 5.3.5.1.6 Case outline 10 5.3.5.1.7 Lead finish . 10 5.3.5.1.8 Absolute maximum ratings 10 5.3.5.1.9 Recommended operating conditions . 10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 v CONTENTS

20、 PARAGRAPH PAGE 5.3.5.2 Section 2, applicable documents 10 5.3.5.2.1 Order of precedence 10 5.3.5.3 Section 3, requirements . 10 5.3.5.3.1 Item requirements 10 5.3.5.3.2 Design, construction and physical dimensions . 10 5.3.5.3.3 Terminal connections . 10 5.3.5.3.4 Block diagram 11 5.3.5.3.5 Truth t

21、ables 11 5.3.5.3.6 Case outline(s) . 11 5.3.5.3.7 Electrical performance characteristics and post irradiation parameter limits . . 11 5.3.5.3.8 Electrical test requirements 11 5.3.5.3.9 Marking 11 5.3.5.3.10 Tables 11 5.3.5.3.11 Graphics . 11 5.3.5.3.12 Certificate of compliance 11 5.3.5.3.13 Certif

22、icate of conformance . 11 5.3.5.3.14 Notification of change . 11 5.3.5.3.15 Verification of change . 11 5.3.6 Section 4, verification . 12 5.3.6.1 Sampling and inspection 12 5.3.6.2 Screening . 12 5.3.6.3 Qualification inspection 12 5.3.6.4 Conformance inspection 12 5.3.6.4.1 Group A inspection . 12

23、 5.3.6.4.2 Group C inspection 12 5.3.6.4.3 Group D inspection 12 5.3.6.4.4 Group E inspection . 12 5.3.6.5 Tables, electrical tests 12 5.3.7 Section 5, packaging 12 5.3.7.1 Packaging requirements 12 5.3.8 Section 6, notes . 12 5.3.8.1 Intended use 12 5.3.8.1.1 Replaceability . 12 5.3.8.1.2 Substitut

24、ability 13 5.3.8.2 Configuration control of SMDs . 13 5.3.8.3 Record of users 13 5.3.8.4 Comments 13 5.3.8.5 Abbreviations, symbols, and definitions . 13 5.3.8.6 Sources of supply . 13 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/C

25、HANGE 1 vi CONTENTS PARAGRAPH PAGE 6 NOTES . 13 6.1 Intended use . 13 6.1.1 Standard microcircuit drawing program (SMDP) . 13 6.2 Draft construction 13 6.3 Certificate of compliance . 13 6.4 Subject term (key word) listing 13 6.5 Change notations 13 FIGURES 1. Drawing, title sheet . 14 2. Drawing, c

26、ontinuation sheet . 15 3. Certificate of compliance 16 4. SMD preparation flowchart . 19 5. SMD with boilerplate . 21 6. Sample SMD 29 * Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 1 1. SCOPE 1.1 Scope. This handbook prov

27、ides guidance and information concerning standard microcircuit drawings (SMDs). System applications are subject to the approval of the applicable program office. This handbook is for guidance only and cannot be cited as a requirement. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed below a

28、re not necessarily all of the documents referenced herein, but are those needed to understand the information provided by this handbook. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to th

29、e extent specified herein. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-38534 - Hybrid Microcircuits, General Specification for MIL-PRF-38535 - Integrated Circuits (Microcircuits) Manufacturing, General Specification for DEPARTMENT OF DEFENSE STANDARD MIL-STD-883 - Test Method Standard Microcircuits

30、 MIL-STD-1835 - Department of Defense Interface Standard, Electronic Component Case Outlines MIL-STD-3018 - Parts Management Standard DEPARTMENT OF DEFENSE HANDBOOK MIL-HDBK-103 - List of Standard Microcircuit Drawings (SMDs) (Copies of these documents are available online at https:/assist.daps.dla.

31、mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the exte

32、nt specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract DEFENSE STANDARDIZATION PROGRAM OFFICE. SD-19 - Parts Management Guide (Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch/ or from the

33、 Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. ASME International (ASME) ASME Y14.5 - Dimensioning and Tolerancing ASME Y14.100

34、- Engineering Drawing Practices (Copies of these documents are available online at http:/www.asme.org/ or from the ASME International, Three Park Avenue, New York, NY 10016-5990). 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, t

35、he text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. * * * * * * * * Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CH

36、ANGE 1 2 3. DEFINITIONS 3.1 Standard microcircuit drawing (SMD). SMDs depict the Governments requirements for an existing commercial item, tested for a military application, disclosing applicable configuration, envelope dimensions, mounting and mating dimensions, interface dimensional characteristic

37、s, specified performance requirements, and inspection and acceptance test requirements as appropriate for a military environment. 3.2 General specification. A general specification is prepared in the six-section format and covers requirements and test procedures that are common to a group of parts,

38、materials, or equipments. It is used with either associated device specifications, specification sheets or SMDs (not a mixture); e.g., MIL-PRF-38534 or MIL-PRF-38535 for microcircuits. 3.3 Military Parts Control Advisory Group (MPCAG). A DoD organization which provides advice to the military departm

39、ents and military contractors on the selection of parts in assigned commodity classes, and collects data on nonstandard parts for developing and updating military specifications and standards. 4. GENERAL GUIDANCE 4.1 Introduction. This section provides general guidelines regarding contents, organiza

40、tion, and paragraphing applicable to the preparation of SMDs. SMDs should be in a standard drawing format in accordance with the guidance contained herein (see figures 1 and 2). 4.2 Sectional arrangement of an SMD. An SMD contains six sections, titled and numbered as shown below. SMDs should be in s

41、tandard drawing format in accordance with ASME Y14.100 (see figures 1 and 2). 1. SCOPE 2. APPLICABLE DOCUMENTS 3. REQUIREMENTS 4. VERIFICATION 5. PACKAGING 6. NOTES 4.2.1 Subject matter. Subject matter should be kept within the scope of the sections so that the same requirements or information will

42、always appear in the same section of every SMD. If there is no information pertinent to a section, the following should appear below the section heading: “This section is not applicable to this drawing“. 4.2.2 Section 1. 4.2.2.1 Scope. The scope should repeat the item name and its modifiers, and pro

43、vide a clear, concise abstract of the coverage of the SMD. This brief statement is the beginning paragraph. The scope should not contain requirements that should be part of section 3. Figures are not included in the scope. 4.2.2.2 Part or Identifying Number (PIN). Section 1 includes a paragraph enti

44、tled “PIN“ which describes how the SMD PIN is constructed (see 5.3.5.1.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-780D w/CHANGE 1 3 4.2.3 Section 2. 4.2.3.1 Listing of references. Section 2 is used to list those documents referenced

45、 in the SMD. Government specifications, standards, adopted non-Government standards, international standardization documents, handbooks, drawings, and approved publications may be referenced in microcircuit drawings. Other non-Government documents promulgated by non-Government standards bodies may a

46、lso be referenced. Government regulations or codes are referenced as applicable. Military Activity Regulations and other documents not readily available from or through the contracting activity are not referenced in an SMD. Care should be taken in referencing non-Government publications to assure th

47、e availability of copies and to acquire prior approval of copyright owner. All those documents identified and referred to in sections 3, 4, and 5 of the SMD are listed in section 2. References are confined to documents currently available at the time of issuance of the SMD. Figures bound integrally

48、with the SMD are not listed in section 2 unless they are reduced-size copies of drawings provided for information only. 4.2.3.1.1 Government documents. Referenced Government documents are listed by document title and identifier excluding revision letters (unless otherwise specified) or suffix (preparing activity symbols) and the “00“ designation for “USED IN LIEU OF“. The titl