1、 MIL-PRF-1/1719C 22 June 2012 SUPERSEDING MIL-PRF-1/1719B 17 August 2004 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE DOD-011 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube describ

2、ed herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: Pulsed, coaxial, tunable frequency range 15,400 to 15,700 MHz, rated peak power output 2.5 kw, with integral magnet. ABSOLUTE RATINGS: Tuner Parameter: if(surge) tk VSWR stop torque T(body) T(anode) T (Input bus

3、hing) Cak tsrv Alt Unit: a sec - inch/ounce C C C pF s ft Maximum: 6 - 1.3:1 20 +71 +150 +175 35 0.150 10,000 Minimum: - 60 - - -54 -54 -54 20 0.06 - ABSOLUTE RATINGS: Parameter: Ef If eb ib Pi pi Du tpc Unit: V A v a W kw - s Maximum: 7 2.5 3,800 3.1 60 12 0.005 0.5 Minimum: 6 1.5 - - - - 0.001 0.2

4、 PHYSICAL CHARACTERISTICS: Dimensions: See figure 1. Marking: 2/ Mounting position: Any. Magnet isolation: 1/ Mounting support: See figure 1. Weight: 4 pounds (maximum). Input coupling: See figure 1. Handling: 1/ Output coupling: See figure 1. Cooling: Conduction and convection. TEST CONDITIONS: Par

5、ameter: Ef ib Du tpc trc Frequency Unit: V a - s s F MHz Tolerance: 0.1 - - 0.05 0.01 F1 15,412 Test condition 1 3/ 6.3 3 .005 0.3 0.07 F2 15,436 Test condition 2 4/ 6.3 3 .001 0.3 0.07 F3 15,484 Test condition 3 5/ 6.3 3 .005 0.3 0.07 F4 15,508 Test condition 4 6/ 6.3 3 .001 0.3 0.07 F5 15,532 F6 1

6、5,568 F7 15,592 F8 15,616 F9 15,664 F10 15,688 _ GENERAL: Qualification Not required. This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. Replaces AIL P/N 395964-1, Litton type L-5328, and Varian type VMU-1018. AMSC N/A FSC 5960 INCH-POUND Provided b

7、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1719C 2 TABLE I. Testing and inspection. Inspection Method Notes Test Conditions Symbol Limits Unit MIL-STD-1311 Min Max First article inspection Temperature range operating (high) 1026 - 18/ - 1, 2 Tes

8、t Frequencies (page 1) F = F1 through F10 TA = +71C MP - 0.1 % Temperature range operating (low) 1026 18/ 1, 2 TA = -54C MP - 0.1 % Barometric pressure, reduced 1002 18/ 1, 2 - - - - Spurious output ratio 4243 9/ - po - -30 dBm Shock, specified pulse (nonoperating) 1042 7/ - 200 G; t = 3 ms F - 1.5

9、MHz Direct-interelectrode capacitance 1331 8/ - C 20 35 pF Tuner stop endurance 4223 17/ - - 50 - inch-ounce Temperature coefficient 4027 18/ 1, 2 TA = +25C to -54C to +71C to +25C F - 3 MHz Mechanical tuning fatigue 4223 10/ - - 1,500 - Cycles Frequency change (warmup) 4302 18/ 3, 4 F - 14 MHz Powe

10、r output (pulse train) - 11/ 18/ 1, 2 po - 0.5 dB Frequency stability (pulse train) - 12/ 18/ 1, 2 F - 1 MHz Frequency stability (filament) - 13/ 18/ 3, 4 Ef = 6.3 V 5% F - 1 MHz Conformance inspection, part 1 Heater current 1301 - - - - Test Frequencies (page 1) F = F1, F4, F7, 10 Ef = 6.3 V; tk =

11、60 sec If 1.5 2.5 A Warmup time (cathode) 4303 - - Ef = 6.3 V; tk = 60 sec (max) - - - - Pulse voltage (anode) 4306 - - eb 3,400 3,700 v Power output 4250 18/ 3, 4 po 2,500 3,500 w See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro

12、m IHS-,-,-MIL-PRF-1/1719C 3 TABLE I. Testing and inspection - Continued. Inspection Method Notes Test Conditions Symbol Limits Unit MIL-STD-1311 Min Max Conformance inspection, part 1 - Continued Frequency pulling figure 4310 - 18/ - 3, 4 Test Frequencies (page 1) F = F1, F4, F7, F10 VSWR = 1.3:1 (m

13、in) F - 5 MHz Frequency pushing figure 4311 18/ 3, 4 ib = 5% F - 0.5 MHz Mechanical tuning range 4223 18/ 3, 4 F 15,400 15.700 MHz Resettability 4223 18/ 3, 4 F - 5 MHz RF bandwidth 4308 15/ 18/ 3, 4 F - 2.5/tpc MHz Minor lobe ratio 4308 15/ 18/ 3,4 Ratio 8 - dB Stability 4315 16/ 18/ 3, 4 MP - 0.1

14、% Conformance inspection, part 2 Operation vibration 1031 - 7/ 18/ - 1, 2 Test Frequencies (page 1) F = F1, F4, F7, F10 F - 1 MHz Tuner torque 4223 - - TA = -54C to +71C - - 20 inch-ounce Conformance inspection, part 3 Life test - - 14/ - - Test Frequencies (page 1) F = F1, F4, F7, F10 t 2,000 - hrs

15、 Life test end points: - Power output 4250 18/ 1, 2 po 2,000 - w Pulse voltage (anode) 4306 - - eb 3,400 3,800 v Mechanical tuning range 4223 - - F 15,400 15,700 MHz Resettability 4223 - - F - 5 MHz RF bandwidth 4308 15/ 18/ 3, 4 F - 3.0/tpc MHz Minor lobe ratio 4308 15/ 18/ 3, 4 Ratio 6 - dB Stabil

16、ity 4315 16/ 18/ 1, 2 MP - 0.2 % See footnotes at top of next page. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1719C 4 TABLE I. Testing and inspection - Continued. 1/ In handling and mounting the tube, care should be exercised to preve

17、nt demagnetization. Ferromagnetic materials or energized magnets shall not be brought within 2 inches of the tube. 2/ A calibrated tuner with appropriate dial markings shall be incorporated on the tube. The tuner mechanism shall be capable of setting the tubes frequency within 5 MHz when the tube is

18、 operating at test condition 1 conditions, TA = 25C, and when the effects of frequency pushing and pulling are neglected. The tuner is to be rotated in a clockwise direction for each new setting. A tuner calibration chart shall be provided for each of the 10 frequencies specified below: Channel No.

19、Frequency 1 . F1 2 . F2 3 . F3 4 . F4 5 . F5 6 . F6 7 . F7 8 . F8 9 . F9 10 . F10 3/ High burst duty. The test shall be performed with a pulse train of 1,667 pulse pairs with a pulse pair spacing of 8 s, and an interpair interval of 60 s. This provides a pulse train of 99.96 ms duration. Pulse train

20、s shall be generated every 200 ms. 4/ Low burst duty. The test shall be performed with a pulse train of 333 pulse pairs with a pulse pair spacing of 8 s, and an interpair interval of 60 s. This provides a pulse train of 19.92 ms duration. Pulse trains shall be generated every 200 ms. 5/ High average

21、 duty. The test shall be performed with constant repetition rate single pulses spaced 60 s. 6/ Low average duty. The test shall be performed with constant repetition rate single pulses spaced 300 s. 7/ After the performance of the specified test, the tube shall meet the requirements of conformance i

22、nspection, part 3, life-test end points. 8/ The input capacitance shall be measured between the cathode terminal and a mounting plate .25 inch (6.35 mm) thick with the minimum cut-out required to flush mount the tube. 9/ Spurious emissions shall not have peak power exceeding the specified amount on

23、the tube specification sheet (TSS) within the frequency range of 7.5 GHz and 20 GHz. This limit not applicable within either the designed emission bandwidth or 5 percent of the center frequency in this TSS. 10/ Tubes shall meet the tuner torque requirements after the specified number of cycles. 11/

24、The difference in amplitude between the first and last rf pulse in the pulse train shall not exceed 0.5 dB under the condition that peak current variation of these two pulses be less than 5 percent total. 12/ The difference in frequency between the third and last pulse in the pulse train shall not e

25、xceed the specified value under the condition that peak current variation of these two pulses be less than 5 percent total. 13/ When the filament voltage is varied as specified, the measured frequency shall not change more than the specified amount. Provided by IHSNot for ResaleNo reproduction or ne

26、tworking permitted without license from IHS-,-,-MIL-PRF-1/1719C 5 TABLE I. Testing and inspection - Continued. 14/ A life-test cycle shall consist of the following: The frequency shall be shifted starting at F1 to the next higher channel each eight operating hours. 15/ The tube shall be operated int

27、o a transmission line with a VSWR of 1.3:1 minimum, adjusted in phase to produce the maximum spectrum degradation. A suitable spectrum is considered one in which the major lobe has a shape such that its slope does not change sign more than once for power levels greater than the specified dB below it

28、s peak. 16/ Stability shall be measured in terms of the average number of output pulses missing, expressed as a percent of the number of input pulses applied during the period of observation. The missing pulses (MP), due to any causes, are considered to be “missing” if the rf energy is less than 70

29、percent of the normal energy level. A VSWR = 1.3:1 (minimum) shall be adjusted to that phase producing maximum instability and the missing pulses counted during any consecutive 5-minute interval of a 10-minute test interval. 17/ Tuner stops shall be provided to limit rotation of the tuner mechanism.

30、 The lower frequency limit shall not be less than 15.375 GHz and the upper frequency limit shall not exceed 15.725 GHz, with the tuner mechanism “set” against the upper or lower stop. 18/ This test shall be performed using the requirements of either of the specified test conditions. Duration Conditi

31、on 5 minutes Off 1 minute Filament voltage applied 60 minutes Tube operating Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/1719C 6 FIGURE 1. Outline drawing of electron tube type DOD-011. Provided by IHSNot for ResaleNo reproduction or ne

32、tworking permitted without license from IHS-,-,-MIL-PRF-1/1719C 7 Dimensions Ltr Inches Millimeters Dimensions Min Max Min Max Ltr Inches Millimeters Conformance inspection, part 2 Min Max Min Max A 2.990 3.010 75.95 76.45 Qualification inspection J 2.262 2.362 57.45 59.99 B 2.490 2.510 63.25 63.75

33、K 1.157 1.217 29.39 30.91 E - 2.000 - 50.80 M 6-32 UNC-2B (4 tapped holes) F .185 .189 4.70 4.80 R .995 1.005 25.27 25.53 U 1.990 2.010 50.55 51.05 S .276 .286 7.01 7.26 Conformance inspection, part 1 T .995 1.005 25.27 25.53 D - 5.000 - 127.00 V .312 - 7.92 - G - 3.550 - 90.17 X .312 - 7.92 - H 3.1

34、70 3.270 80.52 83.06 Y .045 - 1.14 - L .620 .740 15.75 18.80 AB .283 .293 7.19 7.44 N .690 .750 17.53 19.05 Conformance inspection, part 3 P 1.990 2.010 50.55 51.05 Z .095 .101 2.41 2.57 AA .120 .130 3.05 3.30 AC .500 12.70 Nominal dimensions C 1.000 25.40 W .500 12.70 NOTES: 1. The mounting flange

35、shall be brass in accordance with ASTM-B36 and ASTM-B121/B121M, bright alloy finish or aluminum alloy, chemically treated in accordance with MIL-DTL-5541, class 3. 2. The waveguide flange shall have an electrically conductive finish. 3. The location of tuner calibration indicator specified in 2/ of

36、table I shall be viewed through a sealed window. 4. Waveguide flange mates with UG-541/U or equal modified with clearance mounting holes. 5. Cathode-heater terminals mate with Jettron connector No. 90-050 or equal. 6. Slot is .0425 .0020 inch (1.08 .05 mm) wide by .125 .010 inch (3.18 .25 mm) deep.

37、7. The tube labels shall include tube type, serial number, magnet warning data, and calibration markings. 8. Magnet coated with Silastic or equal. FIGURE 1. Outline drawing of electron tube type DOD-011 - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license

38、 from IHS-,-,-MIL-PRF-1/1719C 8 Referenced documents. In addition to MIL-PRF-1, this specification sheet references MIL-STD-1311, ASTM-B36, ASTM-B121/B121M, and MIL-DTL-5541. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made.

39、 This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to

40、the last previous issue. Custodian: Preparing activity: Army - CR DLA - CC Navy - EC DLA - CC (Project 5960-2012-040) Review activities: Army - AR Navy - AS, CG, MC, OS NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-