1、 MIL-PRF-1/781F 29 May 2013 SUPERSEDING MIL-PRF-1/781E 1 May 2007 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, THYRATRON TYPE 6D4 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirement for acquiring the electron tube described herein sh

2、all consist of this specification and MIL-PRF-1. DESCRIPTION: Triode, noise generator. Mounting position: Any. Weight: 0.3 ounce (8.5 grams) nominal. Base: E7-1 (EIA). Envelope: T5-1/2 (5-2). Pin connections: Pin no.: - - - 1 2 3 4 5 6 7 Element: - - - g nc h h k nc a ABSOLUTE RATINGS: Parameter: Ef

3、 Ebb epx epv Ib ib tk Ec1 Unit: V V dc v v mA dc a sec V dc Maximum: 6.93 250 350 350 25 0.110 - -150 Minimum: 5.67 - - - - - 30 - Test conditions: 6.3 125 - - - - - - ABSOLUTE RATINGS: Parameter: Rhk Rg Rp Rk Ehk Du TA Unit: Meg Meg Ohms Ohms V % C Maximum: - - - - -110 0.75 +90 Minimum: - - - - -

4、 -55 Test conditions: 1.0 0.5 650 4,000 - - - _ GENERAL: Qualification - Not required. This specification sheet uses accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A FSC 5960 INCH-POUND INACTIVE FOR NEW DESIGN AFTER 30 APRIL 1997. Provided by IHSNot for ResaleNo repr

5、oduction or networking permitted without license from IHS-,-,-MIL-PRF-1/781F 2 TABLE I. Requirements or tests. Requirement or test MIL-STD-1311 method Notes Conditions Symbol Limits Unit Min Max Conformance inspection, part 1 Grid-cathode voltage Heater current Critical grid voltage for conduction (

6、1) Voltage drop - - - 3241 3201 3204 1 - - - 4 - - - Ec = -20 V dc; Rhk = 0 Rb/Ib = 100 mA dc Egk If Ec Etd - - - 230 -11.0 - - - 2.0 270 -14.0 18 V dc mA V dc V dc Conformance inspection, part 2 Heater-cathode leakage Critical grid voltage for conduction (2) Critical grid voltage for conduction (3)

7、 Noise output (1) Noise output (2) 1336 3201 3201 - - - - - - - - - - - - - - 2 3 Ehk = -100 V dc Ebb = 50 V dc Ebb = 300 V dc Ebb = 300 V dc; Rg = 0; Rp = 56,000 ohms Ebb = 250 V dc; Rg = Rk = 0; Rp = 0.33 Meg Ihk Ec Ec - - - Output - -5.0 -21 - - - 10 15 -7.0 -31 - - - - - - A dc V dc V dc - - - v

8、 Conformance inspection, part 3 Life test Life-test end points: Critical grid voltage for conduction (1) Noise output (2) Low-frequency vibration - - - - - - 3201 - - - 1031 - - - - - - 3 5 Group A; Ebb = 250 V dc; Ec = -20 V dc; Rp = 5,000 ohms; Rhk = disconnected; Ehk = 110 V; t = 500 hours No vol

9、tages applied - - - Ec Output - - - - - - -9.5 9.0 - - - - - - -15.5 - - - - - - - - - V dc v - - - See footnotes at top of next page. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/781F 3 TABLE I. Requirements or tests - Continued. NOTES:

10、 1. Voltage measured across specified grid resistor. 2. The tube shall be placed in the circuit shown (see figure 1) in a constant magnetic field of 375 10 percent gausses perpendicular to the normal electron path. The direction of the magnetic field shall be such as to deflect the electron beam tow

11、ard the top of the tube (north pole of magnet at pin No. 7). The noise voltage measured at the output of the 1,000 Hz bandwidth filter shall not be less than the limits specified below for the various specified frequencies: Frequency, MHz Minimum noise voltage, V rms 0.1 0.2 0.5 1.0 2.0 5.0 10.0 10,

12、000 14,000 25,000 22,000 7,000 500 70 3. The tube shall be placed in the circuit shown (see figure 2) in a constant magnetic field of 375 20 percent gausses which is perpendicular to the normal electron path. The direction of the magnetic field shall be such as to deflect the electron beam toward th

13、e top of the tube. The noise voltage measured at the anode of the tube and across the output of the circuit shall not be less than the specified limit in peak-to-peak volts. The oscilloscope used for noise amplitude measurement shall have a 3 dB video bandwidth extending to at least 4 MHz. 4. This t

14、est shall be the first test performed at the conclusion of the holding period. 5. This test shall be performed according to the life testing schedule given in MIL-PRF-1 paragraph 4.3.8. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/781F 4

15、 FIGURE 1. Noise voltage test circuit. FIGURE 2. Noise voltage test circuit. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/781F 5 Referenced documents. In addition to MIL-PRF-1, this document references MIL-STD-1311. The margins of this s

16、pecification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements

17、of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 (Project 5960-2013-011) DLA - CC Review activities: Army - AR Navy - AS, CG, MC, OS, SH Air For

18、ce - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM C1153-2010(2015) Standard Practice for Location of Wet Insulation in Roofing Systems Using Infrared Imaging《使用红外成像法定位屋面系统中湿隔性的标准实施规程》.pdf ASTM C1153-2010(2015) Standard Practice for Location of Wet Insulation in Roofing Systems Using Infrared Imaging《使用红外成像法定位屋面系统中湿隔性的标准实施规程》.pdf
  • ASTM C1154-2006 Standard Terminology for Non-Asbestos Fiber-Reinforced Cement Products《无石棉的纤维增强水泥制品的标准术语》.pdf ASTM C1154-2006 Standard Terminology for Non-Asbestos Fiber-Reinforced Cement Products《无石棉的纤维增强水泥制品的标准术语》.pdf
  • ASTM C1154-2006(2011) Standard Terminology for Non-Asbestos Fiber-Reinforced Cement Products 《非石棉纤维增强水泥制品的标准术语》.pdf ASTM C1154-2006(2011) Standard Terminology for Non-Asbestos Fiber-Reinforced Cement Products 《非石棉纤维增强水泥制品的标准术语》.pdf
  • ASTM C1154-2006(2016) Standard Terminology for Non-Asbestos Fiber-Reinforced Cement Products《无石棉纤维增强水泥产品的标准术语》.pdf ASTM C1154-2006(2016) Standard Terminology for Non-Asbestos Fiber-Reinforced Cement Products《无石棉纤维增强水泥产品的标准术语》.pdf
  • ASTM C1155-1995(2007) Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data《通过现场数据测定建筑包覆物的热阻的标准实施规程》.pdf ASTM C1155-1995(2007) Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data《通过现场数据测定建筑包覆物的热阻的标准实施规程》.pdf
  • ASTM C1155-1995(2013) Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data《通过现场数据测定建筑包覆物热阻的标准操作规程》.pdf ASTM C1155-1995(2013) Standard Practice for Determining Thermal Resistance of Building Envelope Components from the In-Situ Data《通过现场数据测定建筑包覆物热阻的标准操作规程》.pdf
  • ASTM C1156-2003 Standard Guide for Establishing Calibration for a Measurement Method Used to Analyze Nuclear Fuel Cycle Materials《用于分析核燃料循环材料的测量方法用校准方法的确定的标准指南》.pdf ASTM C1156-2003 Standard Guide for Establishing Calibration for a Measurement Method Used to Analyze Nuclear Fuel Cycle Materials《用于分析核燃料循环材料的测量方法用校准方法的确定的标准指南》.pdf
  • ASTM C1156-2003(2011) Standard Guide for Establishing Calibration for a Measurement Method Used to Analyze Nuclear Fuel Cycle Materials《用于分析核燃料循环材料的测量方法用校准方法的确定的标准指南》.pdf ASTM C1156-2003(2011) Standard Guide for Establishing Calibration for a Measurement Method Used to Analyze Nuclear Fuel Cycle Materials《用于分析核燃料循环材料的测量方法用校准方法的确定的标准指南》.pdf
  • ASTM C1157 C1157M-2009 Standard Performance Specification for Hydraulic Cement《水硬水泥性能规格》.pdf ASTM C1157 C1157M-2009 Standard Performance Specification for Hydraulic Cement《水硬水泥性能规格》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1