1、 MIL-PRF-1/796D 13 January 2012 SUPERSEDING MIL-PRF-1/796C 23 July 1999 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, GAS SWITCHING TYPE 6024 This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the electron tube describ
2、ed herein shall consist of this document and the latest issue of MIL-PRF-1. DESCRIPTION: ATR, waveguide type, F = 2,800 MHz, peak incident power 1.0 kw. ABSOLUTE RATINGS: Parameter: Unit: Transmitter Po kw TA C Alt ft Maximum: Minimum: 1,000 20 +100 -40 10,000 - PHYSICAL CHARACTERISTICS: Dimensions:
3、 Mounting position: See figure 1 Any 2/ TEST CONDITIONS: Parameter: Unit: Transmitter Po kw tp s Du - VSWR - Test 1: Test 2: 20 750 1.0 10% 1.0 10% 0.001 0.001 1.05 1.20 Test frequency: F = 2,800 5.0% See footnotes at end of table I. _ GENERAL: Qualification: Required. This specification sheet uses
4、accept on zero defect sampling in accordance with MIL-PRF-1, table III. AMSC N/A FSC 5960 INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/796D 2 TABLE I. Testing and inspection. Method Limits Inspection MIL-STD-1311 Test Conditio
5、ns Symbol Min Max Unit Qualification inspection Degradation due to vibration 4021 - - - - - Loaded Q 4461 - 2/ QL - 5.5 - Conformance inspection, part 1 Tuning susceptance 4482 - 2/ b -0.05 +0.05 - Firing time 4486 1 2/ 3/ t - 10 sec Arc loss 4488 1 2/ 3/ La - 0.8 dB Temperature cycling (nonoperatin
6、g) 1027 - 1/ - - - - Temperature cycling life test 1027 - Group C 1/ - 50 - Hz Conformance inspection, part 2 High-level VSWR 4474 1 - - 1.15 - Normalized conductance 4484 - 2/ g - 0.05 - Conformance inspection, part 3 Life test 4551 2 Group D 2/ t 1,000 - hrs Life-test end points: - - Tuning suscep
7、tance 4482 - 2/ b -0.05 +0.05 - Normalized conductance 4484 - 2/ g - 0.1 - Firing time 4486 1 2/ 3/ t - 10 sec 1/ Satisfactory test on any one of 1B44, 1B52, 1B53, 1B56, 1B57, 5921, or 5922 ATR tube types made during the same two week period, shall be evidence that all of the group meet this test re
8、quirement. 2/ Mount in accordance with drawing 153-JAN. 3/ The tube shall be mounted as in 2/ and followed by a matched load. The tube shall fire within the limits specified after application of rf power. This test shall be performed at least 7 days after pumping and at least 24 hours after any prev
9、ious discharge. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/796D 3 NOTES: 1. Dimensions are in inches. 2. Dimensions “E“ and “J“ pertain to flange. 3. Dimensions “K“ and “L“ pertain to outside of gasket. 4. Dimension “F“ shall be measur
10、ed prior to attachment of gasket. 5. Gasket to be securely mounted to tube. FIGURE 1. Outline drawing of electron tube type 6024. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/796D 4 Ltr Dimensions Inches Millimeters Min Max Min Max Confo
11、rmance inspection, part 1 A - .625 - 15.88 B - 1.875 - 47.62 C .109 .141 2.77 3.58 D 2.985 3.015 75.82 76.58 F .165 (see note 5) .195 (see note 5) 4.19 4.95 G .347 .377 8.81 9.58 H 1.486 1.516 37.74 38.51 K - 3.223 - 81.86 L - 1.725 - 43.82 N 2.609 2.641 66.27 67.08 Q 4.109 4.141 104.37 105.18 R .20
12、3 DIA (4 holes) .245 DIA (4 holes) 5.16 DIA (4 holes) 6.22 DIA (4 holes) S 2.990 3.010 75.95 76.45 T 1.490 1.510 37.85 38.35 Conformance inspection, part 2 E 3.203 3.233 81.36 82.12 J 1.703 1.733 43.26 44.02 M 2.150 2.350 50.60 59.69 P 2.400 2.600 61.06 66.04 FIGURE 1. Outline drawing of electron tu
13、be type 6024 - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-1/796D 5 Referenced documents. In addition to MIL-PRF-1, this specification sheet references: MIL-STD-1311 153-JAN 189-JAN Custodians: Preparing activity: Army - CR DLA
14、 - CC Navy - EC Air Force - 85 (Project 5960-2011-013) DLA - CC Review activities: Army - AR Navy - AS, CG, MC, OS, SH Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-