DLA MIL-PRF-12934 15 E-2009 RESISTORS VARIABLE WIREWOUND PRECISION STYLE RR3200.pdf

上传人:inwarn120 文档编号:692149 上传时间:2018-12-30 格式:PDF 页数:5 大小:68.96KB
下载 相关 举报
DLA MIL-PRF-12934 15 E-2009 RESISTORS VARIABLE WIREWOUND PRECISION STYLE RR3200.pdf_第1页
第1页 / 共5页
DLA MIL-PRF-12934 15 E-2009 RESISTORS VARIABLE WIREWOUND PRECISION STYLE RR3200.pdf_第2页
第2页 / 共5页
DLA MIL-PRF-12934 15 E-2009 RESISTORS VARIABLE WIREWOUND PRECISION STYLE RR3200.pdf_第3页
第3页 / 共5页
DLA MIL-PRF-12934 15 E-2009 RESISTORS VARIABLE WIREWOUND PRECISION STYLE RR3200.pdf_第4页
第4页 / 共5页
DLA MIL-PRF-12934 15 E-2009 RESISTORS VARIABLE WIREWOUND PRECISION STYLE RR3200.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、Comments, suggestions, or questions on this document should be addressed to: Defense Supply Center, Columbus, ATTN: DSCC VAT, Post Office Box 3990, Columbus, Ohio 43218-3990 or by email Resistordla.mil. Since contact information can change, you may want to verify the currency of this address informa

2、tion using the ASSIST Online database at http:/assist.daps.dla.mil/. AMSC N/A FSC 5905 INCH-POUND MIL-PRF-12934/15E 25 August 2009 SUPERSEDING MIL-PRF-12934/15D 1 February 1999 PERFORMANCE SPECIFICATION RESISTORS, VARIABLE, WIREWOUND, PRECISION, STYLE RR3200 This specification is approved for use by

3、 all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-12934 1. SCOPE 1.1 Scope. This specification covers the requirements for style RR3200, variable, wirewound, precision resistor

4、s. 1.2 Part or Identifying Number (PIN). Variable resistors covered by this specification must be identified by a PIN which must be in the following form. Single-section (cup) resistors RR3200 A 2 A 7 J 103 Style Function and shaft length (1.2.1) Class and center tap (1.2.2) Resistance temperature c

5、haracteristic (1.2.3) Rotational life characteristic (1.2.4) Function conformity tolerance and resistance tolerance characteristic (1.2.5) Resistance (1.2.6) 1.2.1 Function and shaft length. The function and shaft length applicable to this specification is identified by a single symbol in accordance

6、 with table I. TABLE I. Function and shaft length. Symbol Shaft length tolerance 0.03125 (.79) 1/ Function A 0.750 (19.05) Linear B 0.875 (22.23) Linear C 1.000 (25.40) Linear D 1.125 (28.58) Linear E 1.250 (31.75) Linear F 1.375 (34.93) Linear 1/ Metric equivalents are in parentheses. Provided by I

7、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-12934/15E 21.2.2 Class and center tap. The class and center tap applicable to this specification are symbols 2, 3, 4, and 5. 1.2.3 Resistance temperature characteristic. The resistance temperature characteri

8、stic applicable to this specification are symbols A to H, inclusive. 1.2.4 Rotational life characteristic. The rotational life characteristics applicable to this specification are symbols 7, 8, and 9. This potentiometer is capable of operations up to 100 rpm. 1.2.5 Function-conformity tolerance and

9、resistance tolerance characteristics. The function-conformity tolerance and resistance tolerance characteristic applicable to this specification are symbols A to X, Inclusive. 1.2.6 Resistance. The nominal total resistance values and nominal resolution applicable to this specification is in accordan

10、ce with table II. TABLE II. Nominal total resistance and nominal resolution characteristics. Nominal total resistance value Nominal resolution Ohms Percent 100 0.32200 0.27500 0.20 1,000 0.172,000 0.15 5,000 0.11 10,000 0.1020,000 0.092. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this

11、 section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users a

12、re cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this

13、document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation (see 6.2). DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-12934 - Resistors, Variable, Wirewound, Precision, General Specification for. (Copies of these documents are a

14、vailable online at http:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094). 2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein (except for

15、related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MI

16、L-PRF-12934/15E 33. REQUIREMENTS 3.1 General. The requirements for acquiring the product described herein shall consist of this document and MIL-PRF-12934. 3.2 Interface and physical dimensions. The resistors shall meet the interface and physical dimensions specified in figure 1. Inches mm Inches mm

17、 Inches mm Inches mm .005 0.13 .060 1.52 .250 6.35 .750 19.05 .010 0.25 .062 1.57 .281 7.14 .781 19.84 .020 0.51 .100 2.54 .312 7.92 1.093 27.76 .040 1.02 .125 3.18 .625 15.88 1.160 29.46 Style Turns Maximum continuous working voltage (volts) Power rating (watts) 1/ Maximum starting and running torq

18、ue (ounce-inch) Single-turn, single cup Per additional single-turn cup Starting Running Starting Running RR3200 Single 250 1.5 0.5 0.4 0.4 0.3 1/ When single turn units are ganged, the first cup will be full wattage rating, the remaining cups will be 75 percent of rated wattage. NOTES: 1. Dimensions

19、 are in inches. 2. Metric equivalents are given for general information. FIGURE 1. Style RR3200 105 MAXProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-12934/15E 43.3 Minimum total resistance. The minimum total resistance value shall be 100 oh

20、ms. 3.4 Maximum total resistance. The maximum total resistance value shall be 20,000 ohms. 3.5 Mechanical travel. The mechanical travel shall be 360 degrees. 3.6 Actual electrical travel. The theoretical electrical travel shall be 350 degrees 2 degrees. 3.7 Ganged cups. There shall be no more than 3

21、 cups ganged. 3.8 Phasing. For independent linearity the phasing between the cups shall be within 1 degree. This shall be measured, with respect to the first cup, starting from the counterclockwise end point. 3.9 Function. The type of function applicable to this specification shall be independent li

22、nearity. 3.10 Weight. The maximum weight shall be 0.08 pounds and each additional cup shall be 0.04 pounds. 3.11 Hardware. The mounting nut shall be 0.0125 inch thick and shall measure 0.3125 inch across the hexagonal flats. Thread size shall be 0.250-32NEF-2B. Internal-tooth lockwasher of suitable

23、size shall be supplied. 3.12 Pure tin. The use of pure tin, as an underplate or final finish is prohibited both internally and externally. Tin content of resistor components and solder shall not exceed 97 percent, by mass. Tin shall be alloyed with a minimum of 3 percent lead, by mass (see 6.4). 4.

24、VERIFICATIONS. 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-12934. 5. PACKAGING. 5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When packaging of materiel is to be pe

25、rformed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Points packaging activity within the Military Service or Defense Agency, or within t

26、he military services system commands. Packaging data retrieval is available from the managing Military Departments or Defense Agencys automated packaging files, CD-ROM products, or by contacting the responsible packaging activity. 6. NOTES (This section contains information of general or explanatory

27、 nature that may be helpful, but is not mandatory.) 6.1 Intended use. The intended use specified in MIL-PRF-12934 will be applicable to this specification. 6.2 Acquisition requirements. Acquisition documents must specify the following: a. Title, number, and date of this specification, and the comple

28、te PIN (see 1.2). b. Unless otherwise specified (see 2.1), the versions of the individual documents referenced will be those in effect on the date of release of the solicitation.). c. Packaging instructions (see 5.1). 6.3 PIN. This specification requires a PIN that describes technology and appropria

29、te references to associated documents (see 1.2 and 3.1). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-12934/15E 56.4 Tin whisker growth. The use of alloys with tin content greater than 97 percent, by mass, may exhibit tin whisker growth pr

30、oblems after manufacture. Tin whiskers may occur anytime from a day to years after manufacture and can develop under typical operating conditions, on products that use such materials. Conformal coatings applied over top of a whisker-prone surface will not prevent the formation of tin whiskers. Alloy

31、s of 3 percent lead, by mass, have shown to inhibit the growth of tin whiskers. For additional information on this matter, refer to ASTM-B545 (Standard Specification for Electrodeposited Coatings of Tin). 6.5 Changes from previous issue. The margins of this specification are marked with vertical lin

32、es to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire cont

33、ent irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force - 85 Review activities (Project 5905-2009-024) Army - AR, AT, AV, CR4, MI Navy - AS, CG, MC, OS Air Force - 19, 99 NOTE: The activities liste

34、d above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS 5306-1-2006 Code of practice for fire extinguishing installations and equipment on premises - Hose reels and foam inlets《房屋用灭火装置及设备的实施规则 软管卷盘和泡沫引入口》.pdf BS 5306-1-2006 Code of practice for fire extinguishing installations and equipment on premises - Hose reels and foam inlets《房屋用灭火装置及设备的实施规则 软管卷盘和泡沫引入口》.pdf
  • BS 5306-3-2017 Fire extinguishing installations and equipment on premises-Part3 Commissioning and maintenance of portable fire extinguishers-Code of practice《房屋内的灭火装置和设备 第3部分 手提式灭火.pdf BS 5306-3-2017 Fire extinguishing installations and equipment on premises-Part3 Commissioning and maintenance of portable fire extinguishers-Code of practice《房屋内的灭火装置和设备 第3部分 手提式灭火.pdf
  • BS 5306-4-2001+A1-2012 Fire extinguishing installations and equipment on premises Specification for carbon dioxide systems《房屋用灭火装置及设备 二氧化碳系统规格》.pdf BS 5306-4-2001+A1-2012 Fire extinguishing installations and equipment on premises Specification for carbon dioxide systems《房屋用灭火装置及设备 二氧化碳系统规格》.pdf
  • BS 5306-5 1-1992 Code of practice for fire extinguishing installations and equipment on premises - Halon systems - Specification for halon 1301 total flooding systems《房屋灭火装置及设备惯例 第.pdf BS 5306-5 1-1992 Code of practice for fire extinguishing installations and equipment on premises - Halon systems - Specification for halon 1301 total flooding systems《房屋灭火装置及设备惯例 第.pdf
  • BS 5306-5 2-1984 Code of practice for fire extinguishing installations and equipment on premises - Halon systems - Halon 1211 total flooding systems《住宅灭火装置及设备 第5部分 哈朗(聚四氟乙烯)灭火系统 第2.pdf BS 5306-5 2-1984 Code of practice for fire extinguishing installations and equipment on premises - Halon systems - Halon 1211 total flooding systems《住宅灭火装置及设备 第5部分 哈朗(聚四氟乙烯)灭火系统 第2.pdf
  • BS 5306-8-2012 Fire extinguishing installations and equipment on premises Part 8 Selection and positioning of portable fire extinguishers Code of practice《房屋灭火装置及设备 第8部分 便携式灭火器的选择和.pdf BS 5306-8-2012 Fire extinguishing installations and equipment on premises Part 8 Selection and positioning of portable fire extinguishers Code of practice《房屋灭火装置及设备 第8部分 便携式灭火器的选择和.pdf
  • BS 5306-9-2015 Fire extinguishing installations and equipment on premises Recharging of portable fire extinguishers Code of practice《处所内的灭火装置及设备 便携式灭火器的再充装 实践规程》.pdf BS 5306-9-2015 Fire extinguishing installations and equipment on premises Recharging of portable fire extinguishers Code of practice《处所内的灭火装置及设备 便携式灭火器的再充装 实践规程》.pdf
  • BS 5307-1976 Specification - Basic ball-lock punches《普通球锁冲床规范》.pdf BS 5307-1976 Specification - Basic ball-lock punches《普通球锁冲床规范》.pdf
  • BS 5315-1991 Hose clamps (worm drive type) for general purpose use (metric series)《通用软管夹子(蜗杆驱动型)(米制系列)》.pdf BS 5315-1991 Hose clamps (worm drive type) for general purpose use (metric series)《通用软管夹子(蜗杆驱动型)(米制系列)》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有