1、AMSC N/A FSC 5920 INCH-POUND MIL-PRF-15160/15H 3 October 2013 SUPERSEDING MIL-PRF-15160/15G 24 January 2013 PERFORMANCE SPECIFICATION SHEET FUSES, INSTRUMENT, POWER, AND TELEPHONE (NONINDICATING), STYLE F15 This specification is approved for use by all Departments and Agencies of the Department of D
2、efense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-15160. Ltr Inches mm Min Max Min Max A 1.969 2.031 50.01 51.59 B .554 .570 14.07 14.48 C .500 - 12.70 - NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for ge
3、neral information only. FIGURE 1. Style F15, characteristic A. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/15H 2 Ltr Inches mm Min Max Min Max A 1.969 2.031 50.01 51.59 B .554 .570 14.07 14.48 C .500 - 12.70 - D - .130 - 3.30 E .085
4、 - 2.16 - F .140 .164 3.56 4.17 G - .115 - 2.92 H - .150 - 3.81 J .070 - 1.78 - K .026 .036 0.66 0.91 NOTES: 1. Dimensions are in inches. 2. The diameter of the rejection ferrule shall be within zero and minus .050 inch of the diameter of the main contact area. 3. The end of the ferrule shall be fla
5、t with not greater than .015 inch concavity. FIGURE 2. Style F15, characteristic BR. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/15H 3 REQUIREMENTS: Interface and physical dimensions: See figures 1 and 2. Case: Fiber or alternate ma
6、terial. (Alternate to fiber material (tube) shall have an average burst strength of 2,100 pounds per square inch with a value of not less than 1,450 pounds per square inch). Ferrule: Brass. Finish: Nickel, bright alloy, or bright dipped, silver plated when specified. Terminal strength: Method 211 of
7、 MIL-STD-202, test condition E, 5 inch-pound torque between ferrules and fuse body. Electrical: Electrical requirements shall be as specified in table I. Shock: Method 207 of MIL-STD-202, HI shock. Vibration: Method 204 of MIL-STD-202, test condition A (except 5g peak). TABLE I Electrical requiremen
8、ts. Characteristic A BR Voltage rating Overload test 1/ 135% 500% Short circuit test at 250 V dc at 250 V ac at 450 V rms ac 2/ 0 20A fuse 25 30A fuse 250 V ac 250 V dc 450 V rms ac 0 1 hour N/A 10,000A N/A (50% PF max.) 3/8,000A 1,500A 250 V ac 250 V dc N/A 0 1 hour 10 25 seconds 10,000A 200,000A (
9、20% PF max.) N/A N/A 1/ Overload is shown as a percentage of the current rating of the fuse. 2/ Characteristic A fuses may be used for 450 V rms ac. 3/ Power factor (PF). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/15H 4 Part or Ide
10、ntifying Number (PIN): The PIN shall be constructed from table II (e.g., F15A250V1A, or F15BR250V2 1/2A). TABLE II Part or Identifying Number. 1/ Style Characteristic Maximum voltage Current rating F15 F15 A A 250 V 250 V 1A 2A F15 F15 A A 250 V 250 V 3A 5A F15 A 250 V 6A F15 A 250 V 10A F15 A 250 V
11、 15A F15 A 250 V 20A F15 A 250 V 25A F15 A 250 V 30A F15 BR 2/ 250 V 1A F15 BR 2/ 250 V 1 6/10A F15 BR 2/ 250 V 2A F15 BR 2/ 250 V 2 1/2A F15 BR 2/ 250 V 3 2/10A F15 BR 2/ 250 V 4A F15 BR 2/ 250 V 5A F15 BR 2/ 250 V 6 1/4A F15 BR 2/ 250 V 8A F15 BR 2/ 250 V 10A F15 BR 2/ 250 V 12A F15 F15 BR 2/ BR 2
12、/ 250 V 250 V 15A 20A F15 BR 2/ 250 V 25A F15 BR 2/ 250 V 30A 1/ For silver plated terminals, the designator “S” is added after the current rating. 2/ The characteristic B fuse has been discontinued. The characteristic BR fuse may be used to replace the old characteristic B fuse of the same current
13、rating. VERIFICATION: Qualification inspections: The number of qualification samples required shall be: a. 24 samples maximum current rating of each voltage and design. b. 24 samples minimum current rating of each voltage and design. NOTE: If labels are used, five additional samples of any rating ar
14、e required. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/15H 5 Referenced documents. In addition to MIL-PRF-15160, this document references the following: MIL-STD-202 The margins of this specification are marked with vertical lines t
15、o indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content
16、irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity: Army - CR DLA - CC Navy - SH Air Force - 85 (Project 5920-2013-007) DLA - CC Review activities: Army - AT, CR4, MI Navy - AS, CG, MC, OS Air Force - 19, 99 NOTE: The activities listed
17、above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-