DLA MIL-PRF-20 27 G-2011 CAPACITORS FIXED CERAMIC DIELECTRIC (TEMPERATURE COMPENSATING) ESTABLISHED AND NON-ESTABLISHED RELIABILITY STYLES CCR75 AND CC75.pdf

上传人:lawfemale396 文档编号:692559 上传时间:2018-12-30 格式:PDF 页数:4 大小:43.91KB
下载 相关 举报
DLA MIL-PRF-20 27 G-2011 CAPACITORS FIXED CERAMIC DIELECTRIC (TEMPERATURE COMPENSATING) ESTABLISHED AND NON-ESTABLISHED RELIABILITY STYLES CCR75 AND CC75.pdf_第1页
第1页 / 共4页
DLA MIL-PRF-20 27 G-2011 CAPACITORS FIXED CERAMIC DIELECTRIC (TEMPERATURE COMPENSATING) ESTABLISHED AND NON-ESTABLISHED RELIABILITY STYLES CCR75 AND CC75.pdf_第2页
第2页 / 共4页
DLA MIL-PRF-20 27 G-2011 CAPACITORS FIXED CERAMIC DIELECTRIC (TEMPERATURE COMPENSATING) ESTABLISHED AND NON-ESTABLISHED RELIABILITY STYLES CCR75 AND CC75.pdf_第3页
第3页 / 共4页
DLA MIL-PRF-20 27 G-2011 CAPACITORS FIXED CERAMIC DIELECTRIC (TEMPERATURE COMPENSATING) ESTABLISHED AND NON-ESTABLISHED RELIABILITY STYLES CCR75 AND CC75.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、AMSC N/A FSC 5910 MIL-PRF-20/27G 21 April 2011 SUPERSEDING MIL-PRF-20/27F 21 June 2001 PERFORMANCE SPECIFICATION SHEET CAPACITORS, FIXED, CERAMIC DIELECTRIC (TEMPERATURE COMPENSATING), ESTABLISHED AND NON-ESTABLISHED RELIABILITY, STYLES CCR75 AND CC75 This specification is approved for use by all De

2、partments and Agencies of the Department of Defense. The requirements for acquiring the capacitors described herein shall consist of this specification sheet and MIL-PRF-20. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Lead diameter shall be .0

3、16 (0.41 mm) +.005, -.001 (+0.13, -0.03 mm). 4. Lead length may be a minimum of 1.00 inch (25.4 mm) long for use in tape and reel packaging, when specified in the ordering data. FIGURE 1. Styles CCR75 and CC75 capacitors. INCH-POUND CC75 is inactive for new design after 6 June 1984. Use CCR75. Inche

4、s mm .010 0.25 .090 2.29 .160 4.06 1.250 31.75 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/27G 2 REQUIREMENTS: Dimensions and configuration: See figure 1. Lead type: Axial. Case type: Tubular, molded. DC rated voltage: See table I. Ope

5、rating temperature range: -55C to +125C. Characteristic: See table I. Failure rate level (CCR75 only): M (1.0 percent), P (0.1 percent), R (.01 percent) or S (.001 percent). Thermal shock and voltage conditioning (CCR75 only): In accordance with MIL-PRF-20. Capacitance: Within tolerance specified (s

6、ee table I). Dissipation factor: In accordance with MIL-PRF-20. Dielectric withstanding voltage: In accordance with MIL-PRF-20. Body insulation: Test II. Solderability: In accordance with MIL-PRF-20. Resistance to soldering heat: In accordance with MIL-PRF-20. TABLE I. Capacitor characteristics. PIN

7、 1/ 2/ 3/ Rated voltage (volts, dc) Nominal capacitance (pF) Capacitance tolerance PIN 1/ 2/ 3/ Rated voltage (volts, dc) Nominal capacitance (pF) Capacitance tolerance CC-75CXR10- CC-75CXR11- CC-75CXR12- CC-75CXR13- CC-75CXR15- CC-75CXR16- CC-75CXR18- CC-75CXR20- CC-75CXR22- CC-75CXR24- CC-75CXR27-

8、 CC-75CXR30- CC-75CXR33- CC-75CXR36- CC-75CXR39- 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 0.10 0.11 0.12 0.13 0.15 0.16 0.18 0.20 0.22 0.24 0.27 0.30 0.33 0.36 0.39 B B B B B B B B B B B B B B B CC-75CXR43- CC-75CXR47- CC-75CXR51- CC-75CXR56- CC-75CXR62- CC-75CXR68- CC-75CXR75- CC

9、75CXR82- CC-75CXR91- CC-75CX1R0- CC-75CX1R1- CC-75CX1R2- CC-75CX1R3- CC-75CX1R5- CC-75CX1R6- 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 0.43 0.47 0.51 0.56 0.62 0.68 0.75 0.82 0.91 1.0 1.1 1.2 1.3 1.5 1.6 B B B B B B B B B BC BC BC BC BC BC See footnotes at end of table. Provided b

10、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/27G 3 TABLE I. Capacitor characteristics - Continued. PIN 1/ 2/ 3/ Rated voltage (volts, dc) Nominal capacitance (pF) Capacitance tolerance PIN 1/ 2/ Rated voltage (volts, dc) Nominal capacitance (pF)

11、Capacitance tolerance CC-75CX1R8- CC-75CX2R0- CC-75CK2R2- CC-75CK2R4- CC-75CK2R7- CC-75CK3R0- CC-75CK3R3- CC-75CK3R6- CC-75CK3R9- CC-75CJ4R3- CC-75CJ4R7- CC-75CJ5R1- CC-75CJ5R6- CC-75CJ6R2- CC-75CJ6R8- CC-75CJ7R5- CC-75CH8R2- CC-75CH9R1- CC-75CH100- CC-75CH110- CC-75CH120- CC-75CH130- CC-75CH150- CC

12、75CH160- CC-75CH180- CC-75CG200- CC-75CG220- CC-75CG240- CC-75CG270- CC-75CG300- CC-75CG330- CC-75CG360- 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 1.8 2.0 2.2 2.4 2.7 3.0 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.

13、2 9.1 10 11 12 13 15 16 18 20 22 24 27 30 33 36 BC BC BC BC BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD BCD FG FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ CC-75CG390- CC-75CG430- CC-75CG470- CC-75CG510- CC-75CG560- CC-75CG620- CC-75CG680- CC-75CG750- CC-75CG820- CC-75CG910- CC-75CG10

14、1- CC-75CG111- CC-75CG121- CC-75CG131- CC-75CG151- CC-75CG161- CC-75CG181- CC-75CG201- CC-75CG221- CC-75CG241- CC-75CG271- CC-75CG301- CC-75CG331- CC-75CG361- CC-75CG391- CC-75CG431- CC-75CG471- CC-75CG511- CC-75CG561- CC-75CG621- CC-75CG681- 200 200 200 200 200 200 200 200 100 100 100 100 100 100 1

15、00 100 100 100 100 100 50 50 50 50 50 50 50 50 50 50 50 39 43 47 51 56 62 68 75 82 91 100 110 120 130 150 160 180 200 220 240 270 300 330 360 390 430 470 510 560 620 680 FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ 1/ Com

16、plete PIN will include the following: 1st dash - Symbol “R” (for style CCR75) or dash will be deleted (for style CC75). 2nd dash - Applicable capacitance tolerance symbol. 3rd dash - Applicable failure rate level symbol (CCR75 only) or dash will be deleted (for style CC75). 2/ With respect to charac

17、teristics in previous revisions of this specification sheet: for capacitance values of 2 pF or less, characteristic CX is interchangeable with characteristics CG and CH; for capacitance values of 2.2 pF through 3.9 pF, characteristic CK is interchangeable with characteristic CH; for capacitance valu

18、es of 4.3 pF through 7.5 pF, characteristic CJ is interchangeable with characteristic CH; and for capacitance values of 10 pF through 18 pF, characteristic CH is interchangeable with characteristic CG. These parts shall be stocked under the same applicable NSNs. 3/ Temperature coefficient is not pra

19、ctically measurable for characteristic CX capacitors. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/27G 4 Temperature coefficient and capacitance drift: In accordance with MIL-PRF-20. For capacitors with values of 18 pF or less, the temp

20、erature coefficient tolerance shall be determined in accordance with table II. TABLE II. Temperature coefficient tolerances. Permissible capacitance change from capacitance at +25C in ppm/C Temperature Characteristic CX CK CJ CH CG +125C 1/ 250 ppm/C 120 ppm/C 60 ppm/C 30 ppm/C -55C 2/ 1/ +246.25 -3

21、26.25 +116.25 -166.25 +55.00 -91.25 +27.50 -53.75 1/ Not practically measurable. 2/ The ppm/C values for -55C were calculated by dividing ppm by negative 80C. Life: In accordance with MIL-PRF-20, operating condition 2. Part or Identifying Number (PIN): In accordance with MIL-PRF-20 and table I. Mark

22、ing: Method I of MIL-STD-1285, as shown in the following example: JCK - “J” brand (ER only) (J); and characteristic (CK). 2R2 - Capacitance value. CM1 - Capacitance tolerance (C); FR level, CCR75 only (M); and year code (1 for 2011). ATM - Lot code (A); and trademark (TM). Referenced documents. In a

23、ddition to MIL-PRF-20, this specification sheet references the following document: MIL-STD-1285 Changes from previous issue. The margins of this specification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the

24、 Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodians: Prepari

25、ng activity: Army - CR DLA - CC Navy - EC Air Force 85 (Project 5910-2011-011) DLA - CC Review activities: Navy - AS, MC, OS, SH Air Force 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS ISO 17751-2007 Textiles - Quantitative analysis of animal fibres by microscopy - Cashmere wool speciality fibres and their blends《纺织品 显微镜法定量分析动物纤维 羊绒 羊毛 特殊纤维及其混合物》.pdf BS ISO 17751-2007 Textiles - Quantitative analysis of animal fibres by microscopy - Cashmere wool speciality fibres and their blends《纺织品 显微镜法定量分析动物纤维 羊绒 羊毛 特殊纤维及其混合物》.pdf
  • BS ISO 17752-2012 Corrosion of metals and alloys Procedures to determine runoff rates of metals from materials as a result of atmospheric corrosion《金属和铝合金腐蚀 由于空气腐蚀结果造成的来源于材料中金属的径流率.pdf BS ISO 17752-2012 Corrosion of metals and alloys Procedures to determine runoff rates of metals from materials as a result of atmospheric corrosion《金属和铝合金腐蚀 由于空气腐蚀结果造成的来源于材料中金属的径流率.pdf
  • BS ISO 17761-2015 Space environment (natural and artificial) Model of high energy radiation at low altitudes (300 km to 600 km)《航天环境 (天然和人造) 低海拔 (300 km至600 km) 的高能量辐射模型》.pdf BS ISO 17761-2015 Space environment (natural and artificial) Model of high energy radiation at low altitudes (300 km to 600 km)《航天环境 (天然和人造) 低海拔 (300 km至600 km) 的高能量辐射模型》.pdf
  • BS ISO 17770-2017 Space systems Cube satellites (CubeSats)《航天系统 立方体卫星(CubeSats)》.pdf BS ISO 17770-2017 Space systems Cube satellites (CubeSats)《航天系统 立方体卫星(CubeSats)》.pdf
  • BS ISO 17771-2003 Plastics - Thermoset moulding compounds - Determination of the degree of fibre wetting in SMC《塑料 热固性模制化合物 SMC中纤维润湿程度的测定》.pdf BS ISO 17771-2003 Plastics - Thermoset moulding compounds - Determination of the degree of fibre wetting in SMC《塑料 热固性模制化合物 SMC中纤维润湿程度的测定》.pdf
  • BS ISO 17772-1-2017 Energy performance of buildings Indoor environmental quality Indoor environmental input parameters for the design and assessment of energy performance of buildi.pdf BS ISO 17772-1-2017 Energy performance of buildings Indoor environmental quality Indoor environmental input parameters for the design and assessment of energy performance of buildi.pdf
  • BS ISO 17775-2007 Aircraft Ground-service connections Potable water toilet-flush water and toilet drain《航空器 地面设施连接件 饮用水 厕所冲洗水和厕所排水》.pdf BS ISO 17775-2007 Aircraft Ground-service connections Potable water toilet-flush water and toilet drain《航空器 地面设施连接件 饮用水 厕所冲洗水和厕所排水》.pdf
  • BS ISO 17780-2015 Animal and vegetable fats and oils Determination of aliphatic hydrocarbons in vegetable oils《动植物油脂 植物油中脂肪烃的测定》.pdf BS ISO 17780-2015 Animal and vegetable fats and oils Determination of aliphatic hydrocarbons in vegetable oils《动植物油脂 植物油中脂肪烃的测定》.pdf
  • BS ISO 17786-2015 Dimethyl ether (DME) for fuels Determination of high temperature (105C) evaporation residues Mass analysis method《燃料用二甲醚 (DME) 高温 (105 ℃) 蒸发残留物的测定 质量分析法》.pdf BS ISO 17786-2015 Dimethyl ether (DME) for fuels Determination of high temperature (105C) evaporation residues Mass analysis method《燃料用二甲醚 (DME) 高温 (105 ℃) 蒸发残留物的测定 质量分析法》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1