DLA MIL-PRF-27 164 D-2011 TRANSFORMER AND INDUCTORS (AUDIO POWER AND HIGH-POWER PULSE) INDUCTORS HIGH Q.pdf

上传人:priceawful190 文档编号:692663 上传时间:2018-12-30 格式:PDF 页数:3 大小:32.34KB
下载 相关 举报
DLA MIL-PRF-27 164 D-2011 TRANSFORMER AND INDUCTORS (AUDIO POWER AND HIGH-POWER PULSE) INDUCTORS HIGH Q.pdf_第1页
第1页 / 共3页
DLA MIL-PRF-27 164 D-2011 TRANSFORMER AND INDUCTORS (AUDIO POWER AND HIGH-POWER PULSE) INDUCTORS HIGH Q.pdf_第2页
第2页 / 共3页
DLA MIL-PRF-27 164 D-2011 TRANSFORMER AND INDUCTORS (AUDIO POWER AND HIGH-POWER PULSE) INDUCTORS HIGH Q.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC FSC 5950 MIL-PRF-27/164D 22 April 2011 SUPERSEDING MIL-PRF-27/164C 14 February 1995 PERFORMANCE SPECIFICATION SHEET TRANSFORMER AND INDUCTORS (AUDIO, POWER, AND HIGH-POWER PULSE) INDUCTORS, HIGH Q This specification is approved for use by all Departments and Agencies of the Department of Defen

2、se. The requirements for acquiring the products described herein shall consist of this specification and MIL-PRF-27. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Marking shall be on the side of the case. FIGURE 1. Dimensions and configurations.

3、 .484 .031 .438 .031 “X“ H “X“ mAdc “X“ ohms “X“ Q WV : 175 V pk CIRCUIT DIAGRAM AND MARKING 1 2 ALTITUDE 75,000 ft. MAX (SEE TABLE I FOR VALUE OF “X“ .025 DIA 1.000 .125 .563 .031 .344 .016 .203 .016 INCH-POUNDInches mm .016 .025 .031 .203 .344 .438 .484 .563 1.000 0.41 0.64 0.79 5.16 8.74 11.13 12

4、29 14.30 25.40 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-27/164D 2 REQUIREMENTS: (When numbers in parentheses, i.e., (1-2) are used, they indicate the winding and the extreme terminals of the winding.) Electrical ratings: See table I.

5、Working voltage (peak): 175 volts peak. Design and construction: Dimensions and configurations: See figure 1. Case: Metal. Material: Mu metal. Terminals: Tin-lead plated type D4 in accordance with MIL-STD-1276. Weight: .3 ounces maximum. Operating temperature range: -55C to +105C. Altitude: 75,000 f

6、eet maximum. Terminal strength: MIL-STD-202, method 211, test condition A, 2.0 pounds. TABLE I. Electrical ratings. Dash number 1/ (1-2) Inductance 3% H 2/ 3/ (1-2) DC current (max) mA 4/ DC resistance at 25C (1-2) 20% ohms (1-2) Quality factor Q min Voltage (rms) Frequency (Hz) 01 02 03 04 05 06 07

7、 08 09 10 11 .15 .25 .40 .70 1.4 2.5 4.0 6.0 10.0 25.0 60.0 12 9 7 5 3 1 0.7 0.6 0.5 0.3 0.2 33 55 90 135 210 210 340 530 850 2300 5160 18 18 18 18 18 16 16 16 16 16 16 1 1 1 1 1 1 1 1 1 1 1 2000 2000 2000 2000 1500 800 800 800 800 800 800 1/ Qualification testing and approval to M27/164-11 shall be

8、 sufficient to grant qualification approval to M27/164-01 through M27/164-11. 2/ Dash numbers 01 through 05, inductance is measured at 1 kHz, 1 V rms, 0 dc. 3/ Dash numbers 06 through 11, inductance is measured at 400 Hz, 1 V rms, 0 dc. 4/ The dc current is that amount of dc that will reduce the ind

9、uctance by approximately 5 percent (8 percent max.). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-27/164D 3 Dielectric withstanding voltage: See table I. At sea level: 500 V rms. At reduced barometric pressure: 300 V rms. Vibration (high f

10、requency): MIL-STD-202, method 204, test condition D. Marking location: See figure 1. Part or Identifying Number (PIN): M27/164-(dash number from table I). Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue

11、were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relati

12、onship to the last previous issue. Referenced documents. In addition to MIL-PRF-27, this document references the following: MIL-STD-202 MIL-STD-1276 Custodians: Preparing activity: Army CR DLA CC Navy EC Air Force 85 (Project 5950-2009-051) DLA - CC Review activities: Army AR, MI Navy AS, MC, OS, SH

13、 Air Force 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of this information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ANSI UL 331B-2015 UL Standard for Safety Strainers for Diesel Fuel Biodiesel Fuel Diesel Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20) Kerosene and .pdf ANSI UL 331B-2015 UL Standard for Safety Strainers for Diesel Fuel Biodiesel Fuel Diesel Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20) Kerosene and .pdf
  • ANSI UL 340-2017 UL Standard for Safety Test for Comparative Flammability of Liquids (Sixth Edition).pdf ANSI UL 340-2017 UL Standard for Safety Test for Comparative Flammability of Liquids (Sixth Edition).pdf
  • ANSI UL 343-2008 UL Standard for Safety Pumps for Oil-Burning Appliances (Ninth Edition Reprint with Revisions Through and Including December 14 2017).pdf ANSI UL 343-2008 UL Standard for Safety Pumps for Oil-Burning Appliances (Ninth Edition Reprint with Revisions Through and Including December 14 2017).pdf
  • ANSI UL 346-2005 UL Standard for Safety Waterflow Indicators for Fire Protective Signaling Systems (Fifth Edition Reprint with Revisions Through and Including October 30 2014)《防火信令.pdf ANSI UL 346-2005 UL Standard for Safety Waterflow Indicators for Fire Protective Signaling Systems (Fifth Edition Reprint with Revisions Through and Including October 30 2014)《防火信令.pdf
  • ANSI UL 347-2016 Standard for Medium-Voltage AC Contactors Controllers and Control Centres《中压交流电接触器 控制器和控制中心安全性标准》.pdf ANSI UL 347-2016 Standard for Medium-Voltage AC Contactors Controllers and Control Centres《中压交流电接触器 控制器和控制中心安全性标准》.pdf
  • ANSI UL 347A-2015 UL Standard for Safety Medium Voltage Power Conversion Equipment (First Edition Reprint with revisions through and including June 27 2017)《中压电力变换设备安全性标准》.pdf ANSI UL 347A-2015 UL Standard for Safety Medium Voltage Power Conversion Equipment (First Edition Reprint with revisions through and including June 27 2017)《中压电力变换设备安全性标准》.pdf
  • ANSI UL 355-2004 UL Standard for Safety Cord Reels (Tenth Edition Reprint with Revisions Through and Including February 25 2016)《电缆卷盘》.pdf ANSI UL 355-2004 UL Standard for Safety Cord Reels (Tenth Edition Reprint with Revisions Through and Including February 25 2016)《电缆卷盘》.pdf
  • ANSI UL 360-2013 UL Standard for Safety Liquid-Tight Flexible Metal Conduit (Seventh Edition Reprint with Revisions Through and Including May 18 2018)《不透液体软布线钢管安全性标准(提案日期11-2-12)》.pdf ANSI UL 360-2013 UL Standard for Safety Liquid-Tight Flexible Metal Conduit (Seventh Edition Reprint with Revisions Through and Including May 18 2018)《不透液体软布线钢管安全性标准(提案日期11-2-12)》.pdf
  • ANSI UL 363-2011 UL Standard for Safety Knife Switches (Eleventh Edition Reprint with Revisions Through and Including November 13 2015)《闸刀开关安全标准》.pdf ANSI UL 363-2011 UL Standard for Safety Knife Switches (Eleventh Edition Reprint with Revisions Through and Including November 13 2015)《闸刀开关安全标准》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1