DLA MIL-PRF-83383 4 F-2011 CIRCUIT BREAKERS REMOTE CONTROL AC-DC THERMAL TRIP-FREE SERIES TRIP TRIPLE POLE AUXILIARY CONTACTS (5 TO 100 AMPERES).pdf

上传人:Iclinic170 文档编号:693009 上传时间:2018-12-30 格式:PDF 页数:6 大小:60.32KB
下载 相关 举报
DLA MIL-PRF-83383 4 F-2011 CIRCUIT BREAKERS REMOTE CONTROL AC-DC THERMAL TRIP-FREE SERIES TRIP TRIPLE POLE AUXILIARY CONTACTS (5 TO 100 AMPERES).pdf_第1页
第1页 / 共6页
DLA MIL-PRF-83383 4 F-2011 CIRCUIT BREAKERS REMOTE CONTROL AC-DC THERMAL TRIP-FREE SERIES TRIP TRIPLE POLE AUXILIARY CONTACTS (5 TO 100 AMPERES).pdf_第2页
第2页 / 共6页
DLA MIL-PRF-83383 4 F-2011 CIRCUIT BREAKERS REMOTE CONTROL AC-DC THERMAL TRIP-FREE SERIES TRIP TRIPLE POLE AUXILIARY CONTACTS (5 TO 100 AMPERES).pdf_第3页
第3页 / 共6页
DLA MIL-PRF-83383 4 F-2011 CIRCUIT BREAKERS REMOTE CONTROL AC-DC THERMAL TRIP-FREE SERIES TRIP TRIPLE POLE AUXILIARY CONTACTS (5 TO 100 AMPERES).pdf_第4页
第4页 / 共6页
DLA MIL-PRF-83383 4 F-2011 CIRCUIT BREAKERS REMOTE CONTROL AC-DC THERMAL TRIP-FREE SERIES TRIP TRIPLE POLE AUXILIARY CONTACTS (5 TO 100 AMPERES).pdf_第5页
第5页 / 共6页
点击查看更多>>
资源描述

1、AMSC N/A FSC 5925 INCH-POUND MIL-PRF-83383/4F 25 October 2011 SUPERSEDING MIL-PRF-83383/4E 08 December 2004 PERFORMANCE SPECIFICATION SHEET CIRCUIT BREAKERS, REMOTE CONTROL, AC-DC, THERMAL, TRIP-FREE, SERIES TRIP, TRIPLE POLE, AUXILIARY CONTACTS (5 TO 100 AMPERES) This specification is approved for

2、use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-83383. FIGURE 1. Dimensions and configuration. Provided by IHSNot for ResaleNo reproduction or networking permitted with

3、out license from IHS-,-,-MIL-PRF-83383/4F 2 1/ Part number is from National Aerospace Standard NASM315. 2/ Part number is from National Aerospace Standard NASM35338 3/ Part number is from National Aerospace Standard NAS1149. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for gen

4、eral information only. 3. Unless otherwise specified, tolerance is .015 (0.38 mm). FIGURE 1. Dimensions and configuration - Continued. Current rating amperes A B +.030 -.000 C Nut 1/ Lock washer 2/ Flat washer 3/ 5 to 25 .190-32UNC-2A .500 .500 AN315-3R MS35338-43 NAS1149F0332P 35 to 100 .250-28UNF-

5、2A .610 .610 AN315-4R MS35338-44 NAS1149F0463P Inches mm Inches mm Inches mm Inches mm .015 0.38 .127 3.23 .500 12.70 2.526 64.16 .02 0.5 .163 4.14 .600 15.24 2.940 74.68 .030 0.76 .172 4.37 .610 15.49 3.250 82.55 .031 0.79 .183 4.65 .77 19.6 3.29 83.6 .050 1.27 .24 6.1 1.530 38.86 3.43 87.1 .07 1.8

6、 .243 6.17 1.838 46.69 3.69 93.7 .135 3.43 .25 6.4 2.03 51.6 4.26 108.2 .150 3.81 .350 8.89 2.28 57.9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83383/4F 3 NOTE: Terminals 5A and 5B shall be internally grounded to the mounting leg(s). FI

7、GURE 2. Schematic. Note: Terminal junction system (TJS) module shall accept pin contacts P/N M39029/1-100 or -101 as specified in SAE-AS39029/1. FIGURE 3. Terminal junction system module. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83383/

8、4F 4 TABLE I. Dash numbers and characteristics. REQUIREMENTS: Interface and physical dimensions: See figure 1. Weight: 2.250 pounds (1,022 grams), maximum. Trip indication: See figure 1. Terminals: See figures 1 and 2. Auxiliary contact terminals: Contact capacity at 28 V dc and 115 V ac, 400 Hz sha

9、ll be 3 amperes resistive, 1.5 amperes inductive, and 0.5 ampere lamp load. Voltage rating: 115/200 V dc, 400 Hz. Current ratings: See table I. Tripping times: See table I. Response time: 25 milliseconds.Dash Current Tripping times from -54C 5C to +71C 5C (time in seconds) number rating Percent rate

10、d current (amperes) 200 400 1000 Min Max Min Max Min Max 01 5.0 7 80 1.2 10 .3 1.2 02 7.5 11 80 2.4 13 .33 1.1 03 10.0 12 80 2.8 11 .42 1.3 04 15.0 13 80 1.7 10 .35 1.2 05 20.0 14 80 2.9 9.6 .4 1.3 06 25.0 15 80 2.6 10 .4 1.3 07 35.0 16 80 2.8 11 .35 1.3 08 40.0 16 80 2.6 10 .36 1.3 09 50.0 13 80 2.

11、9 10 .4 1.25 10 60.0 13 80 2.4 16 .26 1.8 11 75.0 13 80 2.5 16 .26 1.8 12 80.0 14 80 2.7 12.5 .3 2 13 100.0 17 63 3.5 13 .35 1.9 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-83383/4F 5 Power requirements and response time at minimum voltag

12、e: Standby current drain and actuation current: Test voltage: 28 0.5 V dc to TJS module, then 200 2 V line to line, 400 Hz, 3 phase ground neutral to line terminal. Actuating current, 6.0 amperes dc and 11 amperes ac rms maximum. Maximum operating time at minimum voltage: Test voltage: 181 V ac rms

13、maximum line-to-line, 3 phase. Endurance: Electrical: 5 to 25 amperes: 30,000 cycles resistive or inductive or motor load or lamp load. 35 to 50 amperes: 30, 000 cycles resistive or inductive or motor load or 25,000 cycles lamp load. 60 to 100 amperes: 30,000 cycles resistive or inductive load or 25

14、,000 cycles motor load. Interrupting capacities: G - 3,600 amperes, single phase an 2,160 amperes, three phase. H - 3,600 amperes, single phase and 2,160 amperes, three phase. Other marking: Current rating: See figure 1. Line and load terminals: See figure 1. Terminal junction system (TJS) module: S

15、ee figure 3. Position indication: See figure 1. Indication is provided by a lens over “open” and “closed” on red and green background. Part or Identifying Number (PIN): M83383/04- (dash number from table I) (e.g., M83383/04-01). Provided by IHSNot for ResaleNo reproduction or networking permitted wi

16、thout license from IHS-,-,-MIL-PRF-83383/4F 6 Indicator/control unit (I/CU): In order to maintain compatibility between the RCCB and the I/CU, the following must be observed when making an I/CU selection: a. The I/CU must be a ampere rated circuit breaker (P/N MS22073-1/2 or P/N MS26574-1/2, as spec

17、ified in SAE-AS58091, or equivalent). b. The line impedance (terminal 3 to I/CU) plus the I/CU impedance must not exceed 7.5 ohms. c. The I/CU must respond to a decreasing current pulse of I2t 2 throughout the temperature range. CAUTION TO USERS: Coordination between devices supplied by different ma

18、nufacturers should be verified by the user. Referenced documents. In addition to MIL-PRF-83383, this document references the following: ASTM-D5948 NASM315 NASM35338 NAS1149 SAE-AS58091 SAE-AS39029/1 The margins of this specification are marked with vertical lines to indicate where changes from the p

19、revious issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notati

20、ons and relationship to the last previous issue. Custodians: Preparing activity: Army - CR DLA - CC Navy - AS Air Force - 85 (Project 5925-2011-013) DLA - CC NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM C1485-2006 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source《使用电辐射热能源测定暴露的屋顶层绝热材料辐射通量的标准试验方法》.pdf ASTM C1485-2006 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source《使用电辐射热能源测定暴露的屋顶层绝热材料辐射通量的标准试验方法》.pdf
  • ASTM C1485-2013 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source《使用电辐射热能源测定暴露的屋顶层绝热材料辐射通量的标准试验方法》.pdf ASTM C1485-2013 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source《使用电辐射热能源测定暴露的屋顶层绝热材料辐射通量的标准试验方法》.pdf
  • ASTM C1486-2000 Standard Practice for Testing Chemical-Resistant Broadcast and Slurry-Broadcast Resin Monolithic Floor Surfacings《检验耐化学物质和泥浆扩散的树脂整体地板表面的标准操作规程》.pdf ASTM C1486-2000 Standard Practice for Testing Chemical-Resistant Broadcast and Slurry-Broadcast Resin Monolithic Floor Surfacings《检验耐化学物质和泥浆扩散的树脂整体地板表面的标准操作规程》.pdf
  • ASTM C1486-2000(2012) Standard Practice for Testing Chemical-Resistant Broadcast and Slurry-Broadcast Resin Monolithic Floor Surfacings《检验耐化学物质和泥浆扩散的树脂整体地板表面的标准实施规程》.pdf ASTM C1486-2000(2012) Standard Practice for Testing Chemical-Resistant Broadcast and Slurry-Broadcast Resin Monolithic Floor Surfacings《检验耐化学物质和泥浆扩散的树脂整体地板表面的标准实施规程》.pdf
  • ASTM C1486-2018 Standard Practice for Testing Chemical-Resistant Broadcast and Slurry-Broadcast Resin Monolithic Floor Surfacings《耐化学性广播和泥浆广播树脂整体式地板表面试验的标准实施规程》.pdf ASTM C1486-2018 Standard Practice for Testing Chemical-Resistant Broadcast and Slurry-Broadcast Resin Monolithic Floor Surfacings《耐化学性广播和泥浆广播树脂整体式地板表面试验的标准实施规程》.pdf
  • ASTM C1487-2002(2007) Standard Guide for Remedying Structural Silicone Glazing《修理结构性硅玻璃门窗的标准指南》.pdf ASTM C1487-2002(2007) Standard Guide for Remedying Structural Silicone Glazing《修理结构性硅玻璃门窗的标准指南》.pdf
  • ASTM C1487-2002(2012) Standard Guide for Remedying Structural Silicone Glazing《修理结构性硅玻璃门窗的标准指南》.pdf ASTM C1487-2002(2012) Standard Guide for Remedying Structural Silicone Glazing《修理结构性硅玻璃门窗的标准指南》.pdf
  • ASTM C1488-2004 Standard Practice for Simulated Aging of Cellulosic Loose-Fill Insulation《纤维素疏松填充绝缘材料模拟老化的标准实施规程》.pdf ASTM C1488-2004 Standard Practice for Simulated Aging of Cellulosic Loose-Fill Insulation《纤维素疏松填充绝缘材料模拟老化的标准实施规程》.pdf
  • ASTM C1489-2001 Standard Specification for Lime Putty for Structural Purposes《结构用石灰膏标准规范》.pdf ASTM C1489-2001 Standard Specification for Lime Putty for Structural Purposes《结构用石灰膏标准规范》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1