1、AMSC N/A FSC 5340 MS16993C 17 MAY 2010 SUPERSEDING MS16993B 22 JUNE 1978 DETAIL SPECIFICATION SHEET PLUGS, FUSIBLE, REFRIGERANT - 12 This specification sheet is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein

2、shall consist of this specification. .688 HEXFUSIBLE ALLOY.406 .010.375-18 NPTF (DRYSEAL)STAMP FUSIBLE ALLOYMELTING POINT.281 .010FITTING END AND HEX TOCONFORM TO SAE-J513.375 FLARE1.438 .031.688.625-18UNF-2AFITTING END TO CONFORMTO SAE-J513FIGURE I. Plug, fusible. INCH-POUNDInactive for new design

3、after 1 April 1996.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS16993C 2TABLE I. Part Numbers PART NUMBER FUSIBLE ALLOY MELTING POINT RANGE F (C) MS16993-1 157 (69.4) - 170 (76.6) MS16993-2 208 (97.7) - -220 (104.4) Notes: 1. Material for body,

4、brass bar stock conforming to ASTM B16/B16M. 2. All dimensions in inches. 3. For use with dichlorodifluoromethane (CCI2F2), R-12 refrigerant. 4. To conform to Underwriters Laboratories, Inc. Standard No. UL1995. 5. Marking for identification. In addition to the fusible metal melting point indicated

5、on figure 1, the manufacturers name or equally identifiable trade name shall be clearly applied to the hexagon body of the fusible plug. 6. Workmanship. The fusible plugs shall be free of burrs, rough edges, and disfigured threads. 7. Changes from previous issue. Marginal notations are not used in t

6、his revision to identify changes with respect to the previous issue due to the extent of the changes. Custodians: Preparing Activity: Army -GL DLA -IS Navy - YD Air Force 99 (Project 5340-2010-011) Review activity: Army - MD, MI NOTE: The activities listed above were interested in this document as o

7、f the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • STAS 1785 1-1973 Indoor post insulators made of porce- lain for electrical engineering purpo- ses with outer metal fittings ASSEMBLIED POST INSULATORS (INSULATORS WITH FITTINGS)《电气.pdf STAS 1785 1-1973 Indoor post insulators made of porce- lain for electrical engineering purpo- ses with outer metal fittings ASSEMBLIED POST INSULATORS (INSULATORS WITH FITTINGS)《电气.pdf
  • STAS 1785 2-1980 Indoor post insulators made of porcelain for electrical engineering purposes with outer metal fittings INSULATORS WITHOUT FITTINGS《用于电气工程带有外部金属配件的陶瓷做的室内柱形绝缘子 不带配件的.pdf STAS 1785 2-1980 Indoor post insulators made of porcelain for electrical engineering purposes with outer metal fittings INSULATORS WITHOUT FITTINGS《用于电气工程带有外部金属配件的陶瓷做的室内柱形绝缘子 不带配件的.pdf
  • STAS 1785 3-1973 Indoor post insulators made of porcelan for electrical engineering purposcs with outer metal fittings METAL FITTINGS《电气工程用的带有外部金属配件的室内陶瓷柱绝缘子 金属配件》.pdf STAS 1785 3-1973 Indoor post insulators made of porcelan for electrical engineering purposcs with outer metal fittings METAL FITTINGS《电气工程用的带有外部金属配件的室内陶瓷柱绝缘子 金属配件》.pdf
  • STAS 1785 4-1973 Indoor post insulators made of porcelain for electrical engipeering purposes with outer metal fittings CLOSING DISKS《电气工程用的陶瓷制成的室内柱绝缘子,带有外部金属配件 圆盖板》.pdf STAS 1785 4-1973 Indoor post insulators made of porcelain for electrical engipeering purposes with outer metal fittings CLOSING DISKS《电气工程用的陶瓷制成的室内柱绝缘子,带有外部金属配件 圆盖板》.pdf
  • STAS 1786 1-1989 Indoor bushings with outer metal fittlngs for 7 2 and 12 kV class B INSULATORS WITH FITTINGS《7 2 和 12 千伏的具有外部配件的室内套管B级,带配件的绝缘子》.pdf STAS 1786 1-1989 Indoor bushings with outer metal fittlngs for 7 2 and 12 kV class B INSULATORS WITH FITTINGS《7 2 和 12 千伏的具有外部配件的室内套管B级,带配件的绝缘子》.pdf
  • STAS 1786 2-1973 INDOOR BUSHINGS WITH OUTER METAL FITTINGS FOR 6 AND 10 kV CLASS B INSULATORS  WITHOUT FITTINGS.《6 和 10 千伏的具有外部配件的室内套管,B级,无配件的绝缘子》.pdf STAS 1786 2-1973 INDOOR BUSHINGS WITH OUTER METAL FITTINGS FOR 6 AND 10 kV CLASS B INSULATORS WITHOUT FITTINGS.《6 和 10 千伏的具有外部配件的室内套管,B级,无配件的绝缘子》.pdf
  • STAS 1786 3-1989 INDOOR BUSHINGS WITH OUTER METAL FITTINGS FOR 7 2 AND 12 kV CLASS B JHETAL FITTINGS Dimcnsions《7,2和 12 千伏的具有金属配件的室内套管,B级金属配件尺寸》.pdf STAS 1786 3-1989 INDOOR BUSHINGS WITH OUTER METAL FITTINGS FOR 7 2 AND 12 kV CLASS B JHETAL FITTINGS Dimcnsions《7,2和 12 千伏的具有金属配件的室内套管,B级金属配件尺寸》.pdf
  • STAS 1786 4-1980 INDOOR BUSHINGS WITH OUTER METAL FITTINGS FROM 1 UP TO 35 kV Dimensions《带有外部金属配件的室内套管,电压为1至35千伏 尺寸》.pdf STAS 1786 4-1980 INDOOR BUSHINGS WITH OUTER METAL FITTINGS FROM 1 UP TO 35 kV Dimensions《带有外部金属配件的室内套管,电压为1至35千伏 尺寸》.pdf
  • STAS 1787-1990 Engineer's files Knife files Dimensions《工程锉尺寸》.pdf STAS 1787-1990 Engineer's files Knife files Dimensions《工程锉尺寸》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1