DLA MS21355 REV K-2012 SWITCH TOGGLE POSITIVE BREAK MINIATURE TOGGLE SEALED PRINTED CIRCUIT BOARD TERMINALS DOUBLE POLE 250 MOUNTING BUSHING.pdf

上传人:王申宇 文档编号:696249 上传时间:2019-01-02 格式:PDF 页数:4 大小:108.92KB
下载 相关 举报
DLA MS21355 REV K-2012 SWITCH TOGGLE POSITIVE BREAK MINIATURE TOGGLE SEALED PRINTED CIRCUIT BOARD TERMINALS DOUBLE POLE 250 MOUNTING BUSHING.pdf_第1页
第1页 / 共4页
DLA MS21355 REV K-2012 SWITCH TOGGLE POSITIVE BREAK MINIATURE TOGGLE SEALED PRINTED CIRCUIT BOARD TERMINALS DOUBLE POLE 250 MOUNTING BUSHING.pdf_第2页
第2页 / 共4页
DLA MS21355 REV K-2012 SWITCH TOGGLE POSITIVE BREAK MINIATURE TOGGLE SEALED PRINTED CIRCUIT BOARD TERMINALS DOUBLE POLE 250 MOUNTING BUSHING.pdf_第3页
第3页 / 共4页
DLA MS21355 REV K-2012 SWITCH TOGGLE POSITIVE BREAK MINIATURE TOGGLE SEALED PRINTED CIRCUIT BOARD TERMINALS DOUBLE POLE 250 MOUNTING BUSHING.pdf_第4页
第4页 / 共4页
亲,该文档总共4页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 INCH-POUND MS21355K 4 May 2012 SUPERSEDING MS21355J 4 September 1991 DETAIL SPECIFICATION SHEET SWITCH, TOGGLE, POSITIVE BREAK, MINIATURE, TOGGLE SEALED, PRINTED CIRCUIT BOARD TERMINALS, DOUBLE POLE, .250 MOUNTING BUSHING This specification is approved for use by all Departments and Agencies of the

2、 Department of Defense. The requirements for acquiring the products described herein shall consist of this specification sheet and MIL-DTL-8834. FIGURE 1. Dimensions and configuration. AMSC N/A FSC 5930 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,

3、-MS21355K 2 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .010 (0.25 mm) on decimals and 5 on angles. FIGURE 1. Dimensions and configuration - Continued. Provided by IHSNot for ResaleNo reproduction or

4、networking permitted without license from IHS-,-,-MS21355K 3 REQUIREMENTS: For hardware detail specifications, see appendix of MIL-DTL-8834. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. Refere

5、nced Government documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Dielectric withstanding voltage: For center on circuits, DWV shall be 1,200 V rms at sea level. 115 V ac 6

6、0 hertz electrical endurance tests are to be performed at room temperature and pressure. Switches shall be rigidly mounted by their normal means on a rigid metal panel and subjected to shock test, method 207 of MIL-STD-202. The switch shall be electrically and mechanically operative at the conclusio

7、n of the test and there shall be no mechanical transfer during the test. Terminals: Gold plated. Suitable for mounting on panels. .062 inches (1.57 mm) maximum thickness. Weight: .0143 pound maximum (6.5 grams). Strength of terminals: 5 pounds normal to the mounting plane and 1 pound in other planes

8、. Altitude: 50,000 feet. Strength of actuator: Lever pivot and lever stop 6 pounds. Terminals need not be marked. Terminal identification is shown for reference purposes only. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS21355K 4 TABLE I. Detail

9、 requirements. MS dash no Circuit made between terminals as indicated with the toggle lever in these positions: 1/ Current capacity in amperes Low current level switching 5 mV Resistive load Inductive load 28 V dc 115 V 28 V dc 115 V Opposite locking tab side 4/ Center position Locking tab side 4/ 6

10、0 Hz ac 400 Hz ac 60 Hz ac 400 Hz ac -211 on 2-3 5-6 off on 1-2, 4-5 5 2 3 2/ 1 1 2 3/ 25 A -221 none off -231 on 1-2, 4-5 -241 off none -271 mom-on 2-3, 5-6 mom-on 1-2 4-5 -281 none -311 on 2-3, 5-6 -321 5/ none on 2-3, 5-6 -331 5/ on 2-3, 5-6 2-3 on 4-5 on 1-2, 4-5 -341 5/ mom-on 2-3, 5-6 mom-on 1

11、-2, 4-5 -351 5/ on 2-3, 5-6 1/ Direction of movement of internal mechanism is opposite to the direction of the toggle movement. 2/ With time constant of .020 .002 second. 3/ Contact resistance not to exceed 50 during life, low current level switching. 4/ Non-functional terminals shall not be supplie

12、d. 5/ Delayed action of the switch toggle lever may cause circuit to close or open before snap action mechanism trips. Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Referenced doc

13、uments. In addition to MIL-DTL-8834, this document references MIL-STD-202. Custodians: Preparing activity: Navy - AS DLA CC Air Force - 85 DLA - CC (Project 5930-2011-125) Review activities: Army - MI Navy - EC Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • ASTM C990M-2006 Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants (Metric)《使用预制柔性接头缝密封件的混凝土管道、人孔和预制箱型部件用.pdf ASTM C990M-2006 Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants (Metric)《使用预制柔性接头缝密封件的混凝土管道、人孔和预制箱型部件用.pdf
  • ASTM C990M-2008 Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants (Metric).pdf ASTM C990M-2008 Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants (Metric).pdf
  • ASTM C990M-2009 Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants (Metric)《使用预制挠性接缝密封胶的混凝土管道 人孔和预制箱形件的接缝.pdf ASTM C990M-2009 Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants (Metric)《使用预制挠性接缝密封胶的混凝土管道 人孔和预制箱形件的接缝.pdf
  • ASTM C990M-2009(2014) Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants &40 Metric&41 《使用预制挠性接缝密封胶40 公制4.pdf ASTM C990M-2009(2014) Standard Specification for Joints for Concrete Pipe Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants &40 Metric&41 《使用预制挠性接缝密封胶40 公制4.pdf
  • ASTM C991-2003 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规范》.pdf ASTM C991-2003 Standard Specification for Flexible Glass Fiber Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规范》.pdf
  • ASTM C991-2008 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings.pdf ASTM C991-2008 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings.pdf
  • ASTM C991-2008e1 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规范》.pdf ASTM C991-2008e1 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规范》.pdf
  • ASTM C991-2015 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规格》.pdf ASTM C991-2015 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings《金属建筑物用挠性玻璃纤维绝缘材料标准规格》.pdf
  • ASTM C991-2016 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings《金属建筑用柔性纤维玻璃绝缘的标准规格》.pdf ASTM C991-2016 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings《金属建筑用柔性纤维玻璃绝缘的标准规格》.pdf
  • 相关搜索

    当前位置:首页 > 标准规范 > 国际标准 > 其他

    copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
    备案/许可证编号:苏ICP备17064731号-1