DLA MS24152 REV J-2003 RELAYS ELECTROMAGNETIC 3 PDT 25 AMPERES TYPE II NONHERMETICALLY SEALED (MECHANICALLY INTERLOCKED)《密封II型 3 PDT 25安培电磁继电器》.pdf

上传人:deputyduring120 文档编号:696327 上传时间:2019-01-02 格式:PDF 页数:5 大小:84.53KB
下载 相关 举报
DLA MS24152 REV J-2003 RELAYS ELECTROMAGNETIC 3 PDT 25 AMPERES TYPE II NONHERMETICALLY SEALED (MECHANICALLY INTERLOCKED)《密封II型 3 PDT 25安培电磁继电器》.pdf_第1页
第1页 / 共5页
DLA MS24152 REV J-2003 RELAYS ELECTROMAGNETIC 3 PDT 25 AMPERES TYPE II NONHERMETICALLY SEALED (MECHANICALLY INTERLOCKED)《密封II型 3 PDT 25安培电磁继电器》.pdf_第2页
第2页 / 共5页
DLA MS24152 REV J-2003 RELAYS ELECTROMAGNETIC 3 PDT 25 AMPERES TYPE II NONHERMETICALLY SEALED (MECHANICALLY INTERLOCKED)《密封II型 3 PDT 25安培电磁继电器》.pdf_第3页
第3页 / 共5页
DLA MS24152 REV J-2003 RELAYS ELECTROMAGNETIC 3 PDT 25 AMPERES TYPE II NONHERMETICALLY SEALED (MECHANICALLY INTERLOCKED)《密封II型 3 PDT 25安培电磁继电器》.pdf_第4页
第4页 / 共5页
DLA MS24152 REV J-2003 RELAYS ELECTROMAGNETIC 3 PDT 25 AMPERES TYPE II NONHERMETICALLY SEALED (MECHANICALLY INTERLOCKED)《密封II型 3 PDT 25安培电磁继电器》.pdf_第5页
第5页 / 共5页
亲,该文档总共5页,全部预览完了,如果喜欢就下载吧!
资源描述

1、 AMSC N/A 1 of 5 FSC 5945 DISTRIBUTION STATEMENT A. Approved for public release, distribution is unlimited. INCH-POUND MS24152J 15 April 2003 SUPERSEDING MS24152H 27 May 1994 DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 3 PDT, 25 AMPERES, TYPE II, NONHERMETICALLY SEALED (MECHANICALLY INTERLOC

2、KED) INACTIVE FOR NEW DESIGN AFTER 27 MAY 1994. NO SUPERSEDING SPECIFICATION. This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL

3、-PRF-6106. FIGURE 1. Dimensions and configurations.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS24152J 2 Inches mm Inches mm Inches mm .062 1.57 .625 15.88 2.468 62.69 .125 3.18 .922 23.42 2.750 69.85 .218 5.54 1.062 26.97 4.094 103.99 .250 6.35

4、 1.531 38.89 4.187 106.35 .310 7.87 2.062 52.37 4.750 120.65 .344 8.74 2.141 54.38 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .031 inch (0.79 mm). 4. Additional washer may be used for terminal seat. 5.

5、 Terminal covers and barriers are required at power terminals. 6. In the event of a conflict between the text of this specification and the references cited herein, the text of this specification shall take precedence. 7. Referenced Government documents of the issue listed in that issue of the Depar

6、tment of Defense Index of Specifications and Standards (DoDISS) specified in the solicitation forms a part of this standard to the extent specified herein. 8. Cadmium or cadmium compounds are prohibited on external hardware. A transition period to non-cadmium hardware is authorized for up to 1 year

7、from the date of this revision. 9. Spring washer on drawing is a spring lock washer. FIGURE 1. Dimensions and configuration - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS24152J 3 REQUIREMENTS: Dimensions and configuration: See figure

8、 1. Dash number and general characteristics: See table I. TABLE I. Dash number and general characteristics. PIN MS24152- Type Coil type Terminal type Mounting or mating socket Auxiliary terminals Max weight (pounds) D1 II dc Stud Flange None 2.3 Contact data: Load ratings: See table II. Maximum cont

9、act drop, initial: 0.150 V. After life test: 0.175 V. Overload current (NO): 200 amperes. Rupture current (NO): 250 amperes. TABLE II. Rated contact load (amperes per pole) (case grounded). 1/ 28 V dc 115 V ac, 1 phase 115/200 V ac, 3 phase 2/ Main Aux Main Aux Main Aux Type of load Life oper-ating

10、cycles x 103NO NC NO NC 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz Resistive 50 25 25 25 Inductive 10 25 25 25 Motor 50 25 25 25 Lamp Transfer load 3/ Mechanical life reduced current 100 6.3 6.3 6.3 Mixed loads 50 2.5 2.5 2.5 1/ Absence of value indicates parameter is not applicable to this

11、 specification. 2/ Absence of value indicates relay is not rated for three phase applications. 3/ Transfer load indicates relay is suitable for transfer between unsynchronized ac power supplies at rating indicated. Provided by IHSNot for ResaleNo reproduction or networking permitted without license

12、from IHS-,-,-MS24152J 4 Coil data: See table III. Duty rating: Continuous. RFI specification: MIL-STD-461 (applicable to coil circuits of ac operated relays). TABLE III. Operating characteristics. Coil data Time - (milliseconds maximum) Rated Max Max pick-up voltage Contact bounce 3/ Res 10% Amp Mai

13、n Aux PIN MS 24152- Coil Volts 1/ Freq Hz In-rush Steady state Volts 1.46 0.45 Nor- mal 2/ High Temp test Cont cur- rent test Drop out vol- tage 2/ Hold volt- age 2/ Oper- ate 3/ Rel- ease 4/ NO NC NO NC D1 X1,X2 Y1,Y2 28 dc 22 92 29 0.25 18 21 22.5 1.5 7.0 20 15 3.0 5 / 2 1/ Caution: Use of any coi

14、l voltage less than rated coil voltage will compromise the operation of the relay. 2/ Over the temperature range. 3/ With rated coil voltage. 4/ From rated coil voltage. 5/ 6.0 milliseconds after electrical life. Environmental characteristics: Temperature range: -55C to +71C. Maximum altitude rating

15、: 50,000 feet. Shock, g-level: 25 gs. Duration: 6-9 ms. Maximum duration contact opening: 2 ms. Vibration, sinusoidal: See table IV. Vibration, random: N/A. High shock: N/A. Acceleration: 10 gs. Terminal strength (high temperature pull and torque test): Not applicable. TABLE IV. Vibration levels (si

16、nusoidal). Frequency PIN MS24152- 5-10 Hz 10-55 Hz 55-250 Hz 250-500 Hz D1 .08 DA .06 DA 2 gs 2 gs Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS24152J 5 Electrical data: Minimum insulation resistance: Initial: 100 megohms. After life or environm

17、ental test: 50 megohms. Dielectric strength: Sea level, 2-5 seconds: Initial After life tests 28 V dc 115 V ac 28 V dc 115 V ac Coil to case 1,250 N/A 1,000 N/A Aux. contacts 1,250 N/A 1,000 N/A All other points 1,250 1,500 1,000 1,125 Altitude, 1 minute: 28 V dc 115 V ac Coil to case 500 N/A Aux. c

18、ontacts 500 N/A All other points 700 700 Part or Identifying Number (PIN): MS24152-D1. Qualification by similarity: See MIL-PRF-6106. Supersession data: MS24152-D1 replaces AN3340-2. Performance of group B and group C tests is not applicable. Group A acceptance reports shall be submitted to the preparing activity on a yearly basis to retain qualification. Custodians: Preparing activity:NAVY - AS DLA - CC Air Force - 11 DLA - CC (Project 5945-1206-06) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-

展开阅读全文
相关资源
猜你喜欢
  • BS 7619-2010 Extruded cellular unplasticized white PVC (PVC-UE) profiles - Specification《挤压多孔未增塑白色PVC(PVC-UE)型材 规范》.pdf BS 7619-2010 Extruded cellular unplasticized white PVC (PVC-UE) profiles - Specification《挤压多孔未增塑白色PVC(PVC-UE)型材 规范》.pdf
  • BS 7621-1993 Method for calibrating field pyranometers by comparison to a reference pyranometer《通过与标准日射强度计的比较现场校准日射强度计方法》.pdf BS 7621-1993 Method for calibrating field pyranometers by comparison to a reference pyranometer《通过与标准日射强度计的比较现场校准日射强度计方法》.pdf
  • BS 7623-1993 Electrical and pneumatic analogue chart recorders for use in industrial-process control systems - Guidance for inspection and routine testing《工业处理控制系统用电气和气动模拟图表记录器 检验和.pdf BS 7623-1993 Electrical and pneumatic analogue chart recorders for use in industrial-process control systems - Guidance for inspection and routine testing《工业处理控制系统用电气和气动模拟图表记录器 检验和.pdf
  • BS 7624-2004 Installation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases) - Specification《热输入值6KW及以下的家用直燃式滚筒干燥机的安装和维修.pdf BS 7624-2004 Installation and maintenance of domestic direct gas-fired tumble dryers of up to 6 kW heat input (2nd and 3rd family gases) - Specification《热输入值6KW及以下的家用直燃式滚筒干燥机的安装和维修.pdf
  • BS 7629-1-2015 Electric cables Specification for 300 500 V fire resistant screened fixed installation cables having low emission of smoke and corrosive gases when affected by fire .pdf BS 7629-1-2015 Electric cables Specification for 300 500 V fire resistant screened fixed installation cables having low emission of smoke and corrosive gases when affected by fire .pdf
  • BS 7632-1993 Internal fuses and internal overpressure disconnectors for capacitors for inductive heat generating plants《感应式热发生设备用电容器内部熔断器和内部过压断路器》.pdf BS 7632-1993 Internal fuses and internal overpressure disconnectors for capacitors for inductive heat generating plants《感应式热发生设备用电容器内部熔断器和内部过压断路器》.pdf
  • BS 7634-1993 Specification for oxygen concentrators for use with medical gas pipeline systems《医疗用气体管道系统用氧化浓缩器规范》.pdf BS 7634-1993 Specification for oxygen concentrators for use with medical gas pipeline systems《医疗用气体管道系统用氧化浓缩器规范》.pdf
  • BS 764-1990 Specification for automatic change-over contactors for emergency lighting systems《紧急照明系统用的自动转换接触器规范》.pdf BS 764-1990 Specification for automatic change-over contactors for emergency lighting systems《紧急照明系统用的自动转换接触器规范》.pdf
  • BS 7642-1993 Performance standards in building - Contents and format of standards for evaluation of performance《建筑物的性能标准 性能评估标准的内容和格式》.pdf BS 7642-1993 Performance standards in building - Contents and format of standards for evaluation of performance《建筑物的性能标准 性能评估标准的内容和格式》.pdf