1、AMSC N/A FSC 5930 MS25126L 15 December 2005 SUPERSEDING MS25126K 15 November 1980 DETAIL SPECIFICATION SHEET SWITCHES, TOGGLE, UNSEALED AND SEALED TOGGLE GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Department of Defense. The complete requir
2、ements for acquiring the switch described herein shall consist of this specification and the latest issue of MIL-DTL-83731. FIGURE 1 Dimensions and configurations INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25126L 2FIGURE 1 Dimension
3、s and configurations Continued NOTES: 1. For hardware and terminal screw detail specifications see supplement of MIL-DTL-83731. 2. All dimensions are in inches. 3. Unless otherwise specified, tolerance is .020 on two place decimals and .005 on three place decimals. 4. Locking means optional. 5. For
4、design feature purposed, this standard takes precedence over procurement documents referenced herein. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25126L 3REQUIREMENTS: Superseding No. Superseded No. MS25126-A1 MS25126-1 MS25126-B1 MS25126-2 MS2
5、5126-C1 MS25126-3 MS25126-D1 MS25126-5 MS25126-E1 MS25126-7 MS25126-C3 MS25126-4 MS25126-E3 MS25126-8 MS25126-J4 MS25126-9 MS25126-MII MS25126-6 The superseding dash numbers supersede and are interchangeable with the superseded dash numbers. Example of Part No. MS25126-B1-On off on, toggle seal, loc
6、ked in center off position. All switches on this standard are designed so that the movement of the switch mechanism is opposite to that of the toggle lever. Locking Arrangement: Positive locking shall be accomplished and shall prevent motion of the toggle lever until the locking mechanism is manuall
7、y released. The force required to release the locking mechanism shall be 3 to 5 pounds. Maximum weight is 0.15 pound. Referenced documents shall be of the issue in effect on the date of invitation for bid. Electrical Endurance: 10,000 Cycles. Mechanical Endurance: 20,000 Cycles Electrical rating: Se
8、e table I Table I Detail Requirement Current Capacity (Amperes Per Pole) Circuit with Toggle Lever In 28 VDC 115 VAC 400 Hertz MS part No. Former Ms Part No. Opposite keying side Center Keying side Lamp- load Circuit Resistive circuit Inductive Circuit Lamp- load Circuit Resistive circuit Inductive
9、Circuit MS25126-1 A,B,C,D,E Off On MS25126 -2 Off MS25126-3 C,E None On MS25126-4 B,J Off MS25126-5 Mom. Off None 7 20 15 4 20 15 MS25126-6 L On None MS25126-7 F,H Mom-On MS25126-8 K None Off Mom. On 5 18 10 2 11 8 MS25126 -9 On Mom. Off 7 20 15 4 20 15 MS25126 -10 L Off None MS25126 -11 G,K,M,N On
10、Off Mom. On 5 18 10 2 11 8 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS25126L 4Referenced documents MIL-DTL-83731 Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the c
11、hanges. Custodians: Preparing activity: Army CR DLA CC Navy AS Air Force 11 Project (5930-2005-012) DLA CC Review activities: Army AR, AV, MI Navy EC, MC Air Force 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-